PART 1: HOOD INSTALLATION GUIDE
Ceiling Mounted Cassette and Universal Hung Hood
Models included: X9C12S5 and X5C10S5
14
STEP 1:
Using a weighted string line (plumb line), determine the central position of
hood on the ceiling. It is recommended to centre the hood unit to the cooktop
below. Mark the position. Before making the cut out, check for obstructions
like electrical cables, etc.
NOTE:
The height of the underside of the hood body must be a minimum of 600mm
above an electric cooktop & 650mm above a gas cooktop.
The maximum
recommended height for a cassette unit is 1500mm above the cooktop.
If
the instructions of the hob specify a greater distance than the minimum detailed,
this shall be the minimum height for installation.
Building codes that stipulate a minimum dimension may vary from state to state,
please check with your local council prior to installation.
STEP 2:
Place the two (2) supplied supporting metal beams (500mm long) with
pre-drilled fixing holes perpendicular (90o) to the roof trusses.
STEP 3:
Fit the four (4) supplied 10mm threaded rod through the holes provided on the
supporting metal beams and secure with nuts and washers provided. Ensure
the rod drop height is sufficient to attach the hood and nut fixings but is not
excessive that is will impede the placement of the filters.
STEP 4:
Refer to Part 2: Motor Installation Guide.
STEP 5:
Attach the flexi-ducting to the top of the hood unit and fix into place with a pipe
clamp (provided).
WARNING
DIMENSIONS ARE ACCURATE AT THE TIME OF PRINTING, HAUS GROUP RESERVES THE RIGHT TO
CHANGE SPECIFICATIONS WITHOUT NOTICE. FOR BUILDING PURPOSES THE UNIT SHOULD BE
PROVIDED TO THE CABINET MAKER / BUILDER / KITCHEN DESIGNER FOR EXACT MEASUREMENTS.
Threaded Rod
Supporting Metal Beams