background image

Ref. No. : SM77-05-058-0

                                                                                             Printed : Nov’2005

Page : 15

Part Name

Timer.

Operating Procedure

1. Release

 

screws that hold Rear Cover

at Cabinet.

2. Release

 

screws that hold Timer from

the plate.

3. Hold Recept Terminal then pull out
electrical wires from Timer.

4. After Replacing Timer , reverse the steps above.

Содержание WSN11W

Страница 1: ...age 1 SERVICE MANUAL Refrigerator FOR EXPORT 2005 1 Specifications 1 1 Specific parts for specific countries Item No Model Destination Power Source Voltage ac Hz Power Cord Internal Volume Litre by ISO 8561 1995 1 WSN11W EXPORT 220 50 C4 284 ...

Страница 2: ... Rigid Polyurethane Foam HCFC 141b Refrigerant HFC 134a Refrigerant Charge g 105 Overall Dimension WxDxH mm 606 x 670 x 1 522 Packing Dimension WxDxH mm 657 x 749 x 1 635 Net Weight kg 65 0 Gross Weight kg 65 0 1 3 Characteristic of Thermostat Operating Temperature C 1013hPa mb Model MM1 8612 Dial Position ON OFF WARM C 3 3 NORMAL C 9 1 1 18 1 1 Temperature Control COLD C 25 2 2 1 4 Electrical Par...

Страница 3: ...Ref No SM77 05 058 0 Printed Nov 2005 Page 3 2 Wiring Diagram WSN11W ...

Страница 4: ...odel WSN11W 1 COMPRESSOR 9 DRYER ASS Y 2 TUBE CHARGE 10 TUBE DISCHARGE 3 TUBE CONNECT 139 11 TUBE FRAME 4 ACCUMULATOR MUFFER 12 TUBE CREST 5 TUBE CONNECT 145 13 TUBE CREST S 6 TUBE CONNECT 143 14 EVAPORATOR ASS Y 7 CONDENSER PIPE 15 SUCTION TUBE ASS Y 8 CONDENSER PLATE ...

Страница 5: ...mal 11 94 Ω Approx 18 39 Ω Approx Compressor C BZN152 L6Z Abnormal Open Ω or Short Circuited 0 Ω Measure the resistance with a tester Ambient temperature Room temperature 25 C Model PTH7M220MC1 Normal 22 Ω 20 Approx Starting Relay Abnormal Open Ω or Short Circuited 0Ω Measure the resistance with a tester Ambient temperature Room temperature 25 C Model 4TM734RHBYY 53 Normal Less than 1 Ω Approx Ove...

Страница 6: ...before servicing 1 Model WSN11W Part Name Thermostat Operating Procedure 1 Remove Ice Cube Box 2 Remove Ice Cube Tray 3 Remove Tray Chiller 4 Remove Freezer Corner 5 Adjust Knob Thermo to Min position 6 Pull out Thermo 7 Release screws at FF Cover 8 Lift FF Cover 9 Pull out Thermostat socket ...

Страница 7: ...m Plate MTG Motor 12 Pull out electrical wire from Thermostat by gripping the plug 13 After replacing Thermostat reverse the steps above Part Name Fan Operating Procedure 1 Follow step 1 8 of replacing Thermostat 2 Dig Spring 3 Pull out Fan from Fan Motor 4 After replacing Fan reverse the steps above ...

Страница 8: ...t 2 Press Plate MTG Motor to remove lock 3 Lift Plate MTG Motor out 4 Return the Plate MTG Motor to show behind side 5 Hold Recept Terminal then pull out electrical wire from Fan Motor 6 Dig Spring 7 Pull out Fan from Fan Motor 8 Release screw at Cover A 9 Pull fan motor from Plate MTG Motor 10 Separate Fan Motor from Cover A ...

Страница 9: ... Procedure 1 Follow step 1 11 of replacing Fan Motor 2 Hold the socket of Glass Tube Heater and then pull out 3 Hold the socket of Glass Tube Heater and then pull out 4 Use small steel stick to press at the Recept Terminal while pull out electrical wire 5 Pull out electrical wire from socket 6 Hold and lift Evaporator up 7 Remove aluminium tape that cover electrical wire ...

Страница 10: ... steps above Part Name Bimetal Thermo Operating Procedure 1 Follow step 1 11 of replacing Fan Motor 2 Pull out socket of Bimetal Thermostat 3 Use small steel stick to press at the Recept Terminal while pull out electrical wire 4 Pull out electrical wire from socket 5 Cut out Cable Tie from Evaporator tube 6 Remove Bimetal Thermostat 7 After replacing Bimetal Thermostat reverse the steps above ...

Страница 11: ...1 11 of replacing Fan Motor 2 Pull out socket of Thermal Fuse 3 Use small steel stick to press at the Recept Terminal while pull out electrical wire 4 Pull out electrical wire from socket 5 Cut out Cable Tie from Evaporator tube 6 Remove Thermal Fuse 7 After Replacing Thermal Fuse reverse the steps above ...

Страница 12: ...edure 1 Pull out Tray Chiller 2 Release Door 3 Remove all Tray Chillers 4 Remove Shield Light from Cover Thermostat 5 Turn Knob Thermostat to Min position 6 Pull out Knob Thermostat from Cover Thermostat 7 Dig Cover Cap out 8 Release screw from Cover Thermostat 9 Lift out Cover Thermostat ...

Страница 13: ... from each other 14 Release screws that hold Damper Thermostat and Case Damper 15 Pull Damper Thermostat from Case Damper 16 After replacing Damper Thermostat reverse the steps above Part Name Lamp Operating Procedure 1 Follow step 1 3 of replacing Damper Thermostat 2 Remove Shield Light from Cover Thermostat 3 Turn Lamp counterclockwise to remove 4 After replacing Lamp reverse the steps above ...

Страница 14: ...77 05 058 0 Printed Nov 2005 Page 14 Part Name Door Switch Operating Procedure 1 Dig door switch out 2 Pull door switch from Inner Box 3 Hold recept terminal 4 After replacing Door Switch reverse the steps above ...

Страница 15: ... Part Name Timer Operating Procedure 1 Release screws that hold Rear Cover at Cabinet 2 Release screws that hold Timer from the plate 3 Hold Recept Terminal then pull out electrical wires from Timer 4 After Replacing Timer reverse the steps above ...

Страница 16: ...rating Procedure 1 Release screws that hold Rear Cover and Cabinet 2 Release Relay Cover Fixing Clip 3 Remove Relay Cover 4 Remove Starting Relay 5 Hold Recept Terminal then pull out electrical wires from Starting Relay 6 After Replacing Starting Relay reverse the steps above ...

Страница 17: ... 1 Release screws that hold Rear Cover and Cabinet 2 Release Relay Cover Fixing Clip 3 Remove Relay Cover 4 Remove Starting Relay 5 Remove Overload Protector 6 Hold Recept Terminal then pull out electrical wires from Overload Protector 7 After Replacing Overload Protector reverse the steps above ...

Страница 18: ...er Cover out 2 Remove Dispenser Cover from base 3 Use the screws driver to unlock the housing connectcr of Micro Switch 4 Pull out housing of Micro Switch 5 Release screws of Micro Switch at Dispenser Cover 6 Pull out Micro Switch from Dispenser Cover 7 After replacing Micro Switch reverse the steps above ...

Страница 19: ...Cover from Door Liner 4 Release screws at Water Supply Pump 5 Pull out the housing from inner Door Liner 6 Use the screws driver to unlock the housing connectcr of Water Supply Pump 7 Pull out housing of Water Supply Pump 8 Cut cable tie from Dispenser Tube A 9 Pull out Dispenser Tube A from Dispenser Tube A 10 After replacing Motor Supply Pump reverse the steps above ...

Страница 20: ...tor 2 Used wrench to release screws 3 Release inner screws at Transformer Ass y 4 Release screws that hold Rear Cover at Cabinet 5 Release outside screws at Transformer Ass y 6 Take Transformer Ass y from plate cabinet base 7 Pull out housing of Transformer Ass y 8 Pull out tape 9 Uncover plastic bag from wire set ...

Страница 21: ...Ref No SM77 05 058 0 Printed Nov 2005 Page 21 10 Cut the wire joint 11 Pull out the Transformer Ass y electrical wires 12 After Replacing Transformer Ass y reverse the steps above ...