Functional characteristics
Dispenser heater
According to product model, one or two heater can be
attached to the User Interface board.
Heaters state will be set according to what communicated
by the Main Control board (User Interface board is not
provided with EEPROM so the heaters state will be stored
by Main Control board in case of a main power failure and
communicate when power is restored).
The state of the heaters can be toggled between on or off
pressing the virtual button 2.
No heaters state feedback is foreseen.
Heaters must always be turned off when other loads are
turned on (dispenser light and/or step motor) and during
the start up procedure, i.e. the heaters will be turned on
after 10 seconds and anyway after the initial start up of the
stepper motor has finished.
Heater default state will be set to ON when the system
start.
Содержание WSE 2930 W
Страница 14: ...Range 2012 Novelties 1 New IDI In Door Ice Sankyo ice maker ...
Страница 15: ...Range 2012 Novelties 2 Electronic paddle dispenser version 3 New multiflow channel in fridge compartment ...
Страница 45: ...Functional characteristics NTC senor in the freezer compartment ...
Страница 55: ...Functional characteristics Service Competence Center Sankyo IDI Biruni 7 segment UI Victoria 2010 ...
Страница 86: ...Troubleshooting Documents Service Info WSF 7656 W 8586 462 79100 Whirlpool version ...
Страница 89: ...Technical Data Main Board ...
Страница 92: ...Technical Data Stepper Motor Dispenser assy ...
Страница 93: ...Technical Data Dispenser paddle Switch TS 12M AHM B RS Rating 12V DC 50mA ...
Страница 94: ...Technical Data Dispenser LED Supply voltage nominal 14 V DC 5 ...
Страница 95: ...Technical Data Ice Motor IDI 2 Supply voltage nominal 220 240V DC Rated Torque 11 3N m 0 3 AMPS RPM 15 15 ...
Страница 96: ...Lamps Supply voltage nominal 230 V AC 50 Hz Power dissipation 40 W Technical Data Fridge Freezer compartment ...