COMPONENT ACCESS
Whirlpool Compact Front Load Washer
n
4-11
Removing the Interference Filter
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
To Remove the Interference Filter
1.
Unplug washer or disconnect power.
2.
Turn off water supply to washer.
3.
Perform the procedures on page 4-8, “Removing the Top
Panel” prior to performing the following steps.
4.
Disconnect the Interference Filter’s Line (L) and Neutral
(N) terminals and output connector.
Black Wire
“L” Top
White Wire
“N” Bottom
Interference
Filter
Blue Wires
“Output”
Figure 1
5.
Using a Phillips screwdriver, remove the two (2) screws
securing the interference filter to the back panel. Slide the
filter horizontally to disengage from the back panel and
remove filter from washer.
Slide filter to remove
Remove 2
Screws
Figure 2
6.
When reinstalling the filter, the black wire is on top and
the red wire is on the bottom (see Figure 1).
Interference Filter
Blue Wires
“Output”
Black Wire
“L” Top
White Wire
“N” Bottom