14
NOTE:
Route drain hose out the rear of the dishwasher.
POWER CORD CONNECTION
NOTE:
If removing a previous dishwasher with a power cord,
you will need to transfer the power cord to the new dishwasher.
Use a
1
/
4
"
( 6.35 mm)
nut driver or
1
/
4
"
(6.35 mm)
hex head
socket wrench to remove the screw that holds the terminal
box to the cross brace. Then, tilt the terminal box, free the tab,
and lift the terminal box away from the crossbar.
Remove the cover by sliding it up and lifting its hooks out
of the slot. Retain cover for later use.
21.
Hose clamp final position
Stop Stop
Drain hose stop
Drain hose
Rubber drain hose
connector
Small clamp
22.
Remove terminal box
23.
Remove cover
Install a UL Listed/CSA Approved metallic strain relief.
Make sure screw heads are facing up when tightening
conduit nut. Strain relief is provided with the power cord
kit. See the “Tools and Parts” section at the front of the
guide for part details and orders.
Route cord so that it does not touch dishwasher motor or
lower part of dishwasher tub. Pull cord through strain relief
in terminal box.
NOTE:
A maximum of 2 power cord supply conductors (12 AWG
largest size) plus 1 grounding conductor are permitted in the
terminal box.
24.
Install strain relief
25.
Power cord – route cord
into terminal box
29-Aug-2018 12:50:53 EDT | RELEASED
In some European factories the letter "W" of the part code mentioned herein will be automatically
replaced by the number "4000" (e.g. "W12345678" becomes "400012345678")