background image

7

INSTALLATION INSTRUCTIONS

Prepare Location

It is recommended that the vent system be installed before 
hood is installed.

Do not cut a joist or stud unless absolutely necessary. If a 
joist or stud must be cut, then a supporting frame must be 
constructed.

Before making cutouts, make sure there is proper clearance 
within the ceiling or wall for exhaust vent.

Check your ceiling height and the hood height maximum 
before you select your hood.

1.

If possible, disconnect and move freestanding or slide-in 
range from cabinet opening to provide easier access to rear 
wall. Otherwise, put a thick, protective covering over 
countertop, cooktop or range to protect from damage or dirt. 

2.

Determine which venting method to use: roof, wall, or non-
vented.

3.

Select a flat surface for assembling the range hood. Cover 
that surface with a protective covering.

4.

Using 2 or more people, lift range hood onto protective 
covering.

5.

Determine and mark the centerline on the wall where the 
canopy hood will be installed.

6.

Select a mounting height between a minimum of 
30" (76.2 cm) and a suggested maximum of 36" (91.4 cm), 
above the range to the bottom of the hood and mark 
reference line on the wall.

NOTE:

 For installation locations with reduced ceilings 

heights, the vent hood may be installed using the upper vent 
cover for both vented and non-vented (recirculating) 
installations.

7.

Tape template in place, aligning the template centerline and 
bottom of template with hood bottom line and with the 
centerline marked on the wall.

8.

Mark centers of the 6 fastener locations through the template 
to the wall.

IMPORTANT:

 All screws must be installed into wood.

Remove the template.

9.

Drill 

⁷⁄₆₄

" (2.75 mm) pilot holes at all locations where screws 

are being installed into wood.

10.

Determine and make all necessary cuts in the wall for the vent 
system. Install the vent system before installing the hood. See 
“Venting Requirements” section.

11.

Determine the required height for the ½" conduit and drill a 
1¼" (3.2 cm) hole at this location.

12.

Run wire through the ½" conduit according to the National 
Electrical Code or CSA Standards and local codes and 
ordinances. There must be enough ½" conduit and wires from 
the fused disconnect (or circuit breaker) box to make the 
connection in the hood’s electrical terminal box.

13.

Use caulk to seal all openings.

NOTE:

 Do not reconnect power until installation is complete.

14.

Attach two mounting hooks to the wall at location marked on 
the template.

WARNING

Excessive Weight Hazard

Use two or more people to move and install range.

Failure to do so can result in back or other injury.

WARNING

Excessive Weight Hazard

Use two or more people to move and install 
range hood.

Failure to do so can result in back or other injury.

A. Centerline
B. Mounting hook location

C. Fastener locations
D. Mounting height reference

A. Mounting hooks
B. Centerline on wall

A

B

B

C

D

A

B

Содержание W10029770A

Страница 1: ...CTIONS POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT IMPORTANT Installer Leave installation instructions with the homeowner Homeowner Keep installation instructions for future reference Save installation instructions for local electrical inspector s use IMPORTANT Installateur Remettre les instructions d installation au propriétaire Propriétaire Conserver les instructions d installation pour référence ...

Страница 2: ...arge à l extérieur uniquement 22 Raccordement électrique 23 Achever l installation 23 Installation des filtres 24 Contrôle du fonctionnement 24 UTILISATION DE LA HOTTE DE CUISINIÈRE 24 Fonctionnement 24 ENTRETIEN DE LA HOTTE DE CUISINIÈRE 24 Nettoyage et entretien 24 SCHÉMA DE CÂBLAGE 26 ASSISTANCE OU SERVICE 27 GARANTIE 28 RANGE HOOD SAFETY You can be killed or seriously injured if you don t imme...

Страница 3: ...aust air be sure to duct air outside do not vent exhaust air into spaces within walls ceilings attics crawl spaces or garages WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE Never leave the surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium setting...

Страница 4: ...cian install the range hood It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the left filter on the rear wall of the vent hood Canopy hood location should be away from strong draft areas such as windows doors and strong heating vents Cabinet opening dimensions that are shown must b...

Страница 5: ...ld be on the cold air side of the thermal break The break should be as close as possible to where the vent system enters the heated portion of the house Makeup air Local building codes may require the use of make up air systems when using ventilation systems greater than specified CFM of air movement The specified CFM varies from locale to locale Consult your HVAC professional for specific require...

Страница 6: ...st Pleasant Valley Road Cleveland OH 44131 5575 A 120 Volt 60 Hz AC only 15 amp fused electrical circuit is required Do not ground to a gas pipe Check with a qualified electrician if you are not sure range hood is properly grounded Do not have a fuse in the neutral or ground circuit The range hood must be connected with copper wire only The range hood should be connected directly to the fused disc...

Страница 7: ...ed recirculating installations 7 Tape template in place aligning the template centerline and bottom of template with hood bottom line and with the centerline marked on the wall 8 Mark centers of the 6 fastener locations through the template to the wall IMPORTANT All screws must be installed into wood Remove the template 9 Drill 2 75 mm pilot holes at all locations where screws are being installed ...

Страница 8: ...ssemble the 3 parts of the deflector with two 3 5 x 9 5 mm screws provided The assembled deflector should be sized to fit the width of the vent cover bracket installed earlier 2 Connect the deflector to the vent cover bracket using four 3 5 x 9 5 mm screws provided 3 Measure length of 6 15 2 cm vent needed to connect the transition to the deflector NOTE Vent should fit up inside deflector a minimu...

Страница 9: ... UL listed wire connectors and connect white wires together 7 Connect ground wire to green and yellow ground wire in terminal box using UL listed wire connectors A Mounting hooks B Mounting screws C Leveling screws D Centerline on wall E Transition F 3 5 x 9 5 mm screws G Terminal box A Vent system B Transition piece WARNING Excessive Weight Hazard Use two or more people to move and install range ...

Страница 10: ...o turn off the blower 5 If range hood does not operate check to see whether a circuit breaker has tripped or a household fuse has blown 6 Disconnect power supply 7 Check that the wiring is correct 8 Replace all parts and panels before operating 9 Reconnect power NOTE To get the most efficient use from your new range hood read the Range Hood Use section RANGE HOOD USE Operation The canopy hood is d...

Страница 11: ...grease filters by pushing handle toward the rear and pull downward 3 Pull filter toward front and set aside 4 Repeat to remove other metal filter 5 Install charcoal filter over grille on blower housing and turn filter handle clockwise 6 Repeat to install other charcoal filter To Replace Metal Grease Filters 1 Insert back edge of filter into rear channel of the filter opening 2 Push handle toward t...

Страница 12: ...12 WIRING DIAGRAM ...

Страница 13: ...warranty service anywhere in the United States To locate the Whirlpool designated service company in your area you can also look in your telephone directory Yellow Pages For further assistance If you need further assistance you can write to Whirlpool Corporation with any questions or concerns at Whirlpool Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 ...

Страница 14: ... appliance is used in a country other than the country in which it was purchased DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES CUSTOMER S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED HEREIN IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LA...

Страница 15: ...as de non respect des instructions Votre sécurité et celle des autres est très importante Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager Assurez vous de toujours lire tous les messages de sécurité et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de sécurité Ce symbole d alerte de sécurité vous signale les dangers potentiel...

Страница 16: ...e pas décharger l air aspiré dans un espace vide du bâtiment comme une cavité murale un plafond un grenier un vide sanitaire ou un garage AVERTISSEMENT POUR RÉDUIRE LE RISQUE D INCENDIE UTILISER UNIQUEMENT DES CONDUITS MÉTALLIQUES AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR LA CUISINIÈRE Ne jamais laisser un élément de surface fonctionner à puissance de chauffage maximale sans s...

Страница 17: ...nts en vigueur Confier l installation de la hotte à un technicien qualifié C est à l installateur qu incombe la responsabilité de respecter les distances de séparation exigées spécifiées sur la plaque signalétique de l appareil La plaque signalétique de l appareil est située derrière le filtre de gauche sur la paroi arrière de la hotte On doit toujours installer la hotte à distance des sources de ...

Страница 18: ... nombre de coudes Ne pas utiliser plus de trois coudes à 90 Veiller à ce qu il y ait une section droite de conduit de 24 61 cm ou plus entre deux coudes si on doit utiliser plus de un raccord coudé Ne pas installer 2 coudes ensemble Au niveau de chaque jointure du conduit de décharge assurer l étanchéité avec des brides Autour de la bouche de décharge à l extérieur assurer l étanchéité avec un pro...

Страница 19: ...n et des turbulences de l air ce qui réduit considérablement la performance La sortie à l extérieur du circuit d évacuation peut se faire à travers le toit ou à travers un mur Pour la sortie à travers un mur on doit employer un raccord coudé à 90 Décharge par l arrière Le raccord coudé à 90 peut être installé immédiatement au dessus de la hotte Installation sans décharge à l extérieur recyclage S ...

Страница 20: ...lements en vigueur Un serre câble de 12 7 mm homologation UL ou CSA doit être installé à chaque extrémité du câble d alimentation sur la hotte et sur le boîtier de distribution INSTRUCTIONS D INSTALLATION Préparationdel emplacement On recommande que le circuit d évacuation soit installé avant l installation de la hotte On ne doit couper un poteau de colombage ou une solive que si c est absolument ...

Страница 21: ...ent terminé l installation 14 Fixer 2 crochets de montage au mur aux emplacements marqués sur le gabarit Installation de la bride de cache conduit Installation avec utilisation de télescope et des sections supérieure et inférieure du cache conduit 1 Positionner la bride de cache conduit sur le mur à environ 3 mm du plafond 2 Faire des repères aux emplacements des trous 3 Percer des trous de 9 5 mm...

Страница 22: ...de la hotte utiliser les vis de réglage de l aplomb dans les crochets de montage ou les ouvertures rectangulaires placer un niveau en travers du bas de la hotte pour le contrôle 3 Immobiliser la hotte avec 4 vis de 5 x 35 mm placées dans les 4 trous restants de la hotte 4 Installer le raccord de transition avec 2 vis Installationduconduitd évacuation pourinstallationsavecdéchargeàl extérieur uniqu...

Страница 23: ... section inférieure du cache conduit vers le bas sur la hotte et soulever la section supérieure du cache conduit vers le plafond et installer les 2 vis de 2 9 x 9 5 mm Connecter les sections supérieure et inférieure du cache conduit avec 2 vis de 3 5 x 9 5 mm pour chaque section à partir de l intérieur de la hotte A Serre câble homologation UL ou CSA B Conduit de C Boîte de connexion D Conducteurs...

Страница 24: ...cuisson Pour obtenir les meilleurs résultats mettre le ventilateur de la hotte en marche avant d entreprendre une cuisson et laisser le ventilateur fonctionner pendant plusieurs minutes après l achèvement d une cuisson pour pouvoir évacuer de la cuisine toute trace d odeur de cuisson vapeur ou fumée Tableau de commande de la hotte Les commandes de la hotte sont situées à l avant de la hotte Comman...

Страница 25: ... bord arrière du filtre dans la rainure arrière de l ouverture d installation du filtre 2 Pousser la manette vers l arrière et pousser le filtre vers le haut 3 Tirer le filtre vers l avant pour l insérer dans la rainure avant Remplacement des filtres à charbon 1 Commander l arrêt du ventilateur et l extinction des lampes Vérifier que la lampe à halogène est froide 2 Retirer les filtres à graisse m...

Страница 26: ...OR MATEUR Vitesse du moteur Broches de connexion Résistance ohms entre les broches rouge noir conn jaune blanc rouge jaune conn jaune blanc rouge jaune conn jaune noir BL BL BL BL BL MAR MAR MAR MAR GRIS GRIS GRIS GRIS GRIS GRIS N N N JA JA JA JA JA JA JA N N J V J V J V J V ...

Страница 27: ...clientèle de Whirlpool Canada LP au 1 800 807 6777 Nos consultants vous renseigneront sur les sujets suivants Caractéristiques et spécifications sur toute notre gamme d appareils électroménagers Consignes d utilisation et d entretien Ventes d accessoires et pièces de rechange Références aux marchands locaux aux distributeurs de pièces de rechange et aux compagnies de service Les techniciens de ser...

Страница 28: ...té CLAUSE D EXONÉRATION DE RESPONSABILITÉ AU TITRE DES GARANTIES IMPLICITES LIMITATION DES RECOURS LE SEUL ET EXCLUSIF RECOURS DU CLIENT DANS LE CADRE DE LA PRÉSENTE GARANTIE LIMITÉE CONSISTE EN LA RÉPARATION PRÉVUE CI DESSUS LES GARANTIES IMPLICITES Y COMPRIS LES GARANTIES APPLICABLES DE QUALITÉ MARCHANDE ET D APTITUDE À UN USAGE PARTICULIER SONT LIMITÉES À UN AN OU À LA PLUS COURTE PÉRIODE AUTOR...

Отзывы: