INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
■
Level
■
Drill with 1¼” (3 cm),
³⁄₈
” (9.5 mm),
⁷⁄₆₄
” (2.75 mm) and
¹⁄₈
” (3 mm) drill bits
■
Pencil
■
Wire stripper or utility knife
■
Tape measure or ruler
■
Pliers
■
Caulking gun and weatherproof caulking compound
■
Vent clamps
■
Jigsaw or keyhole saw
■
Flat-blade screwdriver
■
Metal snips
■
Phillips screwdriver
Parts needed
■
¹⁄₂
" conduit
■
Two ½" (12.7 mm) UL listed or CSA approved strain reliefs
■
3 UL listed wire connectors
■
1 wall or roof cap
■
Metal vent system
■
Charcoal Filter Kit Part Number 4396848 for non-vented
(recirculating) installations only. See “Assistance or Service”
section to order.
Parts supplied
Remove parts from packages. Check that all parts are included.
■
Hood canopy assembly with ventilator and light bulbs
installed
■
Deflector for non-vented (recirculating) installations
■
Plastic transition with back draft dampers installed
■
Literature package
■
Filter(s) - depending on model and size
■
2 mounting hooks
■
Vent cover support bracket
■
Mounting template
■
2-piece vent cover
■
4 - 4 x 8 mm screws
■
10 - 3.5 x 9.5 mm screws
■
4 - 5 x 35 mm screws
■
2 - 2.9 x 9.5 mm screws
■
2 - 6 x 70 mm
Location Requirements
IMPORTANT:
Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial rating
plate is located behind the left filter on the rear wall of the vent
hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical
Requirements” section.
The canopy hood is factory set for venting through the roof or
wall. For non-vented (recirculating) Installation see “Non-vented
(recirculating) Installations” in “Prepare Location” section.
Charcoal Filter Kit Part Number 4393848 is available from your
dealer or an authorized parts distributor.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local
codes.
Product Dimensions
11
⁵⁄₁₆
"
(28.7 cm)
10
¹³⁄₁₆
"
(27.5 cm)
21
¹⁄₄
"
(54.0 cm)
min.
33
¹⁄₁₆
"
(84.0 cm)
max.
33
¹⁄₁₆
"
(84.0 cm)
16
⁵⁄₈
"
(42.3 cm)
3
¹⁵⁄₁₆
"
(10.0 cm)
3
¹⁵⁄₁₆
"
(10.0 cm)
135
2
³
/
₈
"
(6.0 cm)
⁷⁄₈
"
(2.3 cm)
14
³⁄₁₆
"
(36.0 cm)
35
³⁄₈
"
(89.8 cm)