Страница 1: ...as supply line to the unit location We suggest using a 74 rigid pipe as smaller size pipe on long runs may result in the gas supply not being sufflclent Pipe joint compounds resistant to the action of LP gas must be used The supply line should be equipped with a shutoff valve This valve should always be located in the same room as the range and should be in a locatlon that allows ease of opening a...

Страница 2: ...r blow off of the burner To convert the pressure regulator Note The type of gas for which the regulator is set IS stamped on the aluml num plug on the top of the regulator either NAT or LPI To change the regulator setting Remove the alumlnunl hex nut plug1 with a wrench orcoln Turn the hex nut or plug over and screw It back Into the regulator Cautton Do not over tighten If the range IS to be used ...

Страница 3: ...into the grounded wall receptacle 4 Check for gas leaks with soapy water When the range is connected and all gas valves have been closed turn on main supply but before lighting the range or putting it to use test all supply line connections and range itself for leaks This range has been factory tested for leaks but sometimes connections work loose in transit NEVER TEST FOR LEAKS WITH A LIGHTED MAT...

Страница 4: ...HT REAR BURNER REACH UNDER TOP AND GRASP THE RECTANGULAR PLUG AT THE BOTTOM OF THE WIRE SHEATH AND PULL UP WITH A SIDE TO SIDE MOTION FOR INSTALLATION IN MOBILE HOME If range IS installed in a mobile home the lnstallatlon must conform with the Federal Standard for Mobile Home Con struction and Safety Title 24 HUD Part 2801 or when such standard IS not applicable with local codes TO INSTALL I Remov...