manualshive.com logo in svg
background image

1

W10096987A
W10097001A-SP

DRYER SAFETY ......................................................................... 2

InSTAllATIon REquIREmEnTS ............................................. 2

Tools and Parts ...................................................................... 2

location Requirements ......................................................... 3

Electrical Requirements ........................................................ 4

Install leveling legs .............................................................. 5

Electrical Connection ............................................................ 6

VEnTInG ................................................................................... 12

Venting Requirements ......................................................... 12

Plan Vent System ................................................................. 13

Venting Kits .......................................................................... 13

Install Vent System .............................................................. 14

Connect Vent ........................................................................ 15

level Dryer ........................................................................... 15

Complete Installation Checklist ......................................... 15

Reverse Door Swing (optional) .......................................... 16

Troubleshooting ................................................................... 19 

ElECTRIC DRYER InSTAllATIon InSTRuCTIonS

29" WIDE moDElS - u.S.A. onlY

Para obtener acceso al manual de uso y cuidado en español, o para obtener información adicional acerca de su producto, visite:  

www.whirlpool.com 

Tenga listo su número de modelo completo. Puede encontrar el número de modelo y de serie dentro de la cavidad superior de la puerta. 

Table of Contents

  

Содержание MEDC200X

Страница 1: ... 14 Connect Vent 15 Level Dryer 15 Complete Installation Checklist 15 Reverse Door Swing Optional 16 Troubleshooting 19 Electric Dryer Installation Instructions 29 Wide Models U S A Only Para obtener acceso al manual de uso y cuidado en español o para obtener información adicional acerca de su producto visite www whirlpool com Tenga listo su número de modelo completo Puede encontrar el número de m...

Страница 2: ...n your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean follow instructions instructions DANGER WARNING INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools an...

Страница 3: ... with upturned ends A UL listed strain relief Location Requirements You will need A location allowing for proper exhaust installation See Venting Requirements A separate 30 amp circuit If you are using power supply cord a grounded electrical outlet located within 2 ft 610 mm of either side of dryer See Electrical Requirements A sturdy floor to support the total weight dryer and load of 200 lbs 90 ...

Страница 4: ...odes and ordinances The National Electrical Code requires a 4 wire power supply connection for homes built after 1996 dryer circuits involved in remodeling after 1996 and all mobile home installations A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 To supply the required 3 or 4 wire single phase 120 240 volt 60 Hz A...

Страница 5: ... receptacle of NEMA Type 14 30 R The ground wire ground conductor may be either green or bare The neutral conductor must be identified by a white cover Then choose a 3 wire power supply cord with ring or spade terminals and UL listed strain relief The 3 wire power supply cord at least 4 ft 1 22 m long must have 3 10 gauge solid copper wires and match a 3 wire receptacle of NEMA Type 10 30R 4 wire ...

Страница 6: ...al block cover Before you start disconnect power Remove hold down screw D and terminal block cover A A Terminal block cover B External ground conductor screw C Center silver colored terminal block screw D Hold down screw E Neutral ground wire F Hole below terminal block cover Power supply cord 4 wire receptacle NEMA Type 14 30R Go to steps 1 2 on page 6 for power supply cord strain relief then ste...

Страница 7: ...other is pointing down D and hold in place Tighten strain relief screws just enough to hold the two clamp sections C together 1 Power supply cord strain relief 4 wire Power Supply Cord Connection Remove center silver colored terminal block screw B Remove neutral ground wire E from external ground conductor screw A A E B Prepare to connect neutral ground wire and neutral wire 3 B C E Connect neutra...

Страница 8: ...dryer rear panel Secure cover with hold down screw Now go to Venting Requirements A F Connect ground wire F green or bare of power supply cord to external ground conductor screw A Tighten screw 5 Connect ground wire 4 Connect neutral wire Connect neutral wire white or center C of power supply cord to center silver colored terminal block screw B Tighten screw B C 5 Connect remaining wires Connect r...

Страница 9: ...f Put direct wire cable through the strain relief The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position Tighten strain relief screws For 3 wire Direct Wire Connection see page 10 For 4 wire Direct Wire Connection continue to step 3 on this page 2 Attach direct wire cable to strain relief Direct wire strain relief Direct wire cable must have 5 ft 1 52 m of...

Страница 10: ...8 Connect remaining wires B C E 6 Connect neutral ground wire and neutral wire Connect neutral ground wire E and place hooked end hook facing right of neutral wire white or center wire C of direct wire cable under center screw of terminal block B Squeeze hooked ends together and tighten screw Direct wire cable must have 5 ft 1 52 m of extra length so dryer may be moved if needed Strip 31 2 89 mm o...

Страница 11: ...ternal ground conductor screw A to an adequate ground Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements Optional 3 wire Connection You must verify with a qualified electrician that this grounding method is acceptable before connecting Connect remaining wires 7 Place hooked ends of remaining direct wire cable ...

Страница 12: ...g vent system clean lint from entire length of the system and make sure exhaust hood is not plugged with lint Replace plastic or metal foil vents with rigid metal or flexible metal vents Review Vent system chart and if necessary modify existing vent system to achieve best drying performance Only a 4 102 mm heavy metal exhaust vent and clamps may be used Do not use plastic or metal foil vent Exhaus...

Страница 13: ...r purchase Venting Kits For more information call 1 800 901 2042 or visit us at www applianceaccessories com In Canada call 1 800 807 6777 or visit us at www whirlpoolparts ca Part Number Descriptions 8171587RP 0 5 Metal vent periscope 4396037RP 0 18 Metal vent periscope 4396011RP 18 29 Metal vent periscope 4396014 29 50 Metal vent periscope 4392892 In Wall metal DuraVent Periscope 4396028 Sure Co...

Страница 14: ...lations The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home Terminate the exhaust vent outside Determine vent path Select route that will provide straightest and most direct path outdoors Plan installation to use fewest number of elbows and turns When using elbows or making turns allow as much room as po...

Страница 15: ...m under the dryer Complete Installation Checklist q Check that all parts are now installed If there is an extra part go back through steps to see what was skipped q Check that you have all of your tools q Dispose of recycle all packaging materials q Check dryer s final location Be sure vent is not crushed or kinked q For power supply cord installation plug into an outlet For direct wire installati...

Страница 16: ...ugs into hinge holes on opposite side of dryer cabinet Remove and transfer hinge hole plugs 4 Remove bottom screws 2 Open dryer door Remove bottom screws from dryer cabinet side of hinges Loosen do not remove top screws from dryer cabinet side of hinges q When the dryer has been running for 5 minutes open the dryer door and feel for heat If you feel heat cancel cycle and close the door If you do n...

Страница 17: ...r catch left or right within slot to adjust alignment Check door strike alignment 6 Super Wide Side Swing Door Place towel on top of dryer to avoid damaging the surface Place towel on dryer 1 Remove bottom screws 2 Open dryer door Remove bottom screws from dryer cabinet side of hinges Loosen do not remove top screws from dryer cabinet side of hinges Lift door until top screws in dryer cabinet are ...

Страница 18: ...t 4 door screws Attach door hinges 8 Reattach door hinges to dryer door so that the larger hole is at the bottom of the hinge Flip door over 7 Flip door over so handle side is down Remove screws at top bottom and side of door 4 screws Keep door screws separate from hinge screws as they are diferent sizes Holding door over towel on dryer grasp sides of outer door and lift to separate it from inner ...

Страница 19: ...th screw Insert door strike plug into original door strike hole and secure with screw Remove door strike plug 12 Close door and check that door strike aligns with door catch If it is needed slide door catch left or right within slot to adjust alignment Check door strike alignment 13 Use a small flat blade screwdriver to gently remove 4 hinge hole plugs on left side of dryer cabinet Transfer plugs ...

Страница 20: ...20 W10096987A W10097001A SP 2010 Whirlpool Corporation 2 10 All rights reserved Printed in U S A Registered Trademark TM Trademark of Whirlpool U S A ...

Отзывы: