Страница 1: ...and Parts 3 Location Requirements 3 Electrical Requirements 5 INSTALLATION INSTRUCTIONS 6 Unpack Range 6 Adjust Leveling Legs 6 Install Anti Tip Bracket 7 Electrical Connection 8 Verify Anti Tip Bracket Location 13 Level Range 14 Complete Installation 14 Moving the Range 15 iMPORTANT Save for local electrical inspector s use W10270322A ...

Страница 2: ...hese words mean You can be killed or seriously injured if you don t immediately follow instructions You can be killed or seriously injured if you don t follow instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Tip Over Hazard A childor adult can tip the range and b...

Страница 3: ...or convenient use in the kitchen To eliminate the risk of burns or fire by reaching over heated surface units cabinet storage space located above the surface units should be avoided If cabinet storage is to be provided the risk can be reduced by installing a range hood that projects horizontally a minimum of 5 12 7 cm beyond the bottom of the cabinets Cabinet opening dimensions that are shown must...

Страница 4: ...tion A 13 33 cm upper cabinet depth B 30 76 2 cm min opening width C For minimum clearance to the top of the cooktop see NOTE D 30 76 2 cm min opening width E Cabinet door or hinge should not extend into cutout H F 3 wire shaded area 7 17 8 cm min from left side cabinet 53 4 14 6 cm max from floor 6 15 2 cm max width G 4 wire shaded area 10 25 4 cm min from right side cabinet 53 4 14 6 cm max from...

Страница 5: ...e 14 50P plug on the supply end The fourth grounding conductor must be identified by a green or green yellow cover and the neutral conductor by a white cover Cord should be Type SRD or SRDT with a UL listed strain relief and be at least 4 ft 1 22 m long 4 wire receptacle 14 50R The minimum conductor sized for the copper 4 wire power cord are This range is manufactured with the neutral terminal con...

Страница 6: ...ne with the range on its back or with the range supported on 2 legs after the range has been placed back to a standing position NOTE To place range back up into a standing position put a sheet of cardboard or hardboard in front of range Using 2 or more people stand range back up onto the cardboard or hardboard Tip Over Hazard A child or adult can tip the range and be killed Connect anti tip bracke...

Страница 7: ... the left side or right side of the cutout Position mounting bracket in cutout so that right or left edge of the bracket is 15 16 2 4 cm from the marked edge of the range as shown A B A Anti tip bracket B Mark edge of range C 15 16 2 4 cm Drill two 1 8 3 0 mm holes that correspond to the bracket holes of the determined mounting method See the following Wall Mounting A B A 12 x 1 screws B Anti tip ...

Страница 8: ... electrical shock 1 2 Disconnect power Use Phillips screwdriver to remove the terminal block cover screw located on the back of the range Pull cover down and toward you to remove cover Style 1 Power supply cord strain relief Assemble a UL listed strain relief in the opening lil i i 3 Remove plastic tag holding three 10 32 hex nuts from the middle post of the terminal block 4 Add strain relief A UL...

Страница 9: ... listed conduit connector in the opening 5 6 A Removable retaining nut B Strain relief Feed the flexible conduit through the strain relief allowing enough slack to easily attach wiring to the terminal block Tighten strain relief screw against the flexible conduit Replace back panel and screws on rear of range Complete installation following instructions for your type of electrical connection 4 wir...

Страница 10: ... strap must be cut out and removed 2 A Metal ground strap B Discard C Ground link screw Use Phillips screwdriver to remove the ground link screw from the back of the range Save the ground link screw and the end of the ground link under the screw A Terminal block B Ground link screw C Cord conduit plate D Power supply cord wires 4 Use Phillips screwdriver to connect the green ground wire from the p...

Страница 11: ...ter connection opening with ring terminals and marked for use with ranges 5 Replace terminal block access cover Direct Wire Installation Copper or Aluminum Wire This range may be connected directly to the fuse disconnect or circuit breaker box Depending on your electrical supply make the required 3 wire or 4 wire connection 1 Strip outer covering back 3 7 6 cm to expose wires Strip the insulation ...

Страница 12: ...taching terminal lugs to the terminal block 20 Ibs in 2 3 N m Wire Awg Torque 8 gauge copper 25 Ibs in 2 8 N m 6 gauge aluminum 35 Ibs in 4 0 N m 5 6 Use Phillips screwdriver to connect the bare green ground wire to the range with the ground link screw The ground wire must be attached first and must not contact any other terminal Use 3 8 nut driver to connect the neutral white wire to the center t...

Страница 13: ... 1 black bare green ground and line 2 red wires Loosen do not remove the setscrew on the front of the terminal lug and insert exposed wire end through bottom of terminal lugs Securely tighten setscrew to XX Ibs in torque See Bare Wire Torque Specifications chart C D A Terminal lug B Setscrew C Line 1 black wire D Bare green ground wire E Line 2 red wire D C A 10 32 hex nut B Line 1 black C Ground ...

Страница 14: ...e of recycle all packaging materials 4 Check that the range is level See Level Range 5 Use a mild solution of liquid household cleaner and warm water to remove waxy residue caused by shipping material Dry thoroughly with a soft cloth For more information read the Range Care section of the Use and Care Guide 6 Read the range Use and Care Guide 7 Turn power on Turn on surface burners and oven See th...

Страница 15: ...ly cord 5 To check that anti tip bracket is installed use a flashlight and look underneath the bottom of the range Look for the anti tip bracket securely attached to floor or wall Slide range back so rear range foot is under anti tip bracket Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical sho...

Страница 16: ...W10270322A 2009 Whirlpool Corporation All rights reserved 5 09 Printed in U S A ...