background image

PRODUCT MODEL SERIES

PRODUCT DIMENSIONS

GBD309PV
GBS309PV
RBD305PV

RBD307PV
RBS305PV
RBS307PV

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.

Ref. W10192049B

09-05-08

30" (76.2 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN

A. 28

⁵⁄₁₆

" (71.9 cm) max. recessed width 

B.

29

" (73.7 cm) max. overall height 

C. 29

³⁄₄

" (75.6 cm) overall width

D. 23" (58.4 cm) max. recessed depth 

E. 27

¹⁄₂

" (69.9 cm) recessed height 

A

B

C

D

E

®

CABINET DIMENSIONS

A. 28

⁵⁄₁₆

" (71.9 cm) max. recessed width 

B.

51

" (129.5 cm) max. overall height 

C. 29

³⁄₄

" (75.6 cm) overall width

D. 23" (58.4 cm) max. recessed depth 

E. 49

⁹⁄₁₆

" (125.9 cm) recessed height 

A

B

D

E

C

Single Oven

Double Oven

S

ingle Oven Undercounter 

(without cooktop installed above)

A.

30

" (76.2 cm) min. cabinet width 

B. 1

¹⁄₂

" (3.8 cm) min. top of cutout to 

underside of countertop 

C. 5

¹⁄₄

" (13.3 cm) bottom of cutout to floor 

D. 28

¹⁄₂

" (72.4 cm) cutout width

E. 27

³⁄₄

" (70.5 cm) min. cutout height 

A

B

C

D

E

S

ingle Oven Installed in Cabinet

A.

30

" (76.2 cm) min. cabinet width 

B. 1" (2.5 cm) top of cutout to bottom 

of upper cabinet door

C.

32

" (81.3 cm) bottom of cutout to floor 

D. 28

¹⁄₂

" (72.4 cm) cutout width

E. 1

¹⁄₂

" (3.8 cm) min. bottom of cutout to 

top of cabinet door

F. 27

³⁄₄

" (70.5 cm) cutout height

A

B

D

E

F

C

t

e

n

i

b

a

C

 

n

i

 

d

e

l

l

a

t

s

n

I

 

s

n

e

v

O

 

e

l

b

u

o

D

A.

30

" (76.2 cm) min. cabinet width 

B. 1" (2.5 cm) top of cutout to bottom of 

upper cabinet door

C. 14

³⁄₄

" (37.5 cm) bottom of cutout to floor 

D. 28

¹⁄₂

" (72.4 cm) cutout width

E. 1

¹⁄₂

" (3.8 cm) min. bottom of cutout to 

top of cabinet door

F. 49

³⁄₄

" (126.4 cm) min. cutout height 

A

B

C

D

E

F

 

n

e

v

O

 

e

l

b

u

o

D

 

r

o

 

e

l

g

n

i

S

 

-

 

w

e

i

V

 

e

d

i

S

 

t

e

n

i

b

a

C

A. 23

¹⁄₄

" (59.1 cm) min. cutout depth

B. 23" (58.4 cm) recessed oven depth
C. Oven front
D. Recessed oven

E. Cabinet

A

B

C

D

E

Electrical Requirements:

Oven must be connected

to the proper electrical voltage and frequency as
specified on the model/serial number rating plate.
The model/serial number rating plate is located at
the bottom of the right-hand mounting rail. See the
following illustrations. 

Models rated from 7.3 to 9.6 kW at 240 volts 
(5.5 to 7.2 kW at 208 volts) require a separate 
40-amp circuit. Models rated at 7.2 kW and below
at 240 volts (5.4 kW and below at 208 volts)
require a separate 30-amp circuit.

A circuit breaker is recommended. Connect directly
to the circuit breaker box (or fused disconnect)
through flexible, armored or nonmetallic, sheathed
copper cable (with grounding wire).

Flexible conduit from the oven should be
connected directly to the junction box. Do not cut
the conduit. The length of conduit provided is for
serviceability of the oven. A UL-listed or CSA-
approved conduit connector must be provided.

If the house has aluminum wiring, follow the
procedure below:

1. Connect a section of solid copper wire to the

pigtail leads.

2. Connect the aluminum wiring to the added

section of copper wire using special connectors
and/or tools designed and UL-listed for joining
copper to aluminum.

Follow the electrical connector manufacturer's
recommended procedure. Aluminum/copper
connection must conform with local codes and
industry-accepted wiring practices.

Single Oven

A. Model/serial number plate

Double Oven

A. Model/serial number plate

A

A

Содержание GBD309PV Series

Страница 1: ... bottom of cutout to floor D 28 72 4 cm cutout width E 1 3 8 cm min bottom of cutout to top of cabinet door F 49 126 4 cm min cutout height A B C D E F n e v O e l b u o D r o e l g n i S w e i V e d i S t e n i b a C A 23 59 1 cm min cutout depth B 23 58 4 cm recessed oven depth C Oven front D Recessed oven E Cabinet A B C D E Electrical Requirements Oven must be connected to the proper electrica...

Страница 2: ... for oven and cooktop be located in the adjacent right or left cabinet A 1 2 5 cm minimum diameter hole should have been drilled in the upper rear right or left corner of the side wall surface to pass the appliance cable through to the junction box On models with Steam Assist it will be necessary to drill a 1 3 cm minimum diameter hole in the upper right or left rear corner of the side wall to pas...

Страница 3: ... Assist it will be necessary to drill a 1 1 3 cm minimum diameter hole in the upper right or left rear corner of the side wall to pass the water supply tubing through to the undersink water filter If water supply tubing hole is drilled on the same side as the oven cable hole a minimum of 2 5 1 cm is required between the 2 holes A 24 61 cm cabinet depth B 25 63 5 cm countertop depth C Recommended o...

Страница 4: ...d between the 2 holes The upper shaded areas are recommended locations for recessed junction box for 120 volt grounded outlet for cooktop Lower shaded areas are recommended locations for flexible or rigid gas pipe installation The gas pipe can be installed on either side of the cutout and either through the floor or through the wall A 24 61 cm cabinet depth B 1 2 5 cm clearance to bottom of counte...

Страница 5: ...4 Notes ...

Страница 6: ...recommande que les boîtiers de connexion pour four et table de cuisson soient situés dans le placard adjacent à droite ou à gauche Un trou de diamètre 1 2 5 cm ou plus doit avoir été percé dans la partie supérieure de l angle arrière gauche ou droit de la surface de la paroi latérale pour le passage du câble d alimentation de l appareil jusqu au boîtier de connexion Sur les modèles avec injection ...

Страница 7: ...faudra percer un trou d un diamètre de 1 1 3 cm minimum dans l angle supérieur droit ou inférieur gauche de la paroi latérale pour le passage de la canalisation d eau jusqu au filtre à eau sous l évier Si le trou de la canalisation d eau est percé du même côté que celui du câble du four une distance minimale de 2 5 1 cm est nécessaire entre les 2 trous A Profondeur de placard 24 61 cm B Profondeur...

Страница 8: ... grisées supérieures pour la prise de 120 volts reliée à la terre du boîtier de connexion encastré de la table de cuisson On recommande l installation de la canalisation de gaz flexible ou rigide dans la zone ombrée inférieure La canalisation de gaz peut être installée d un côté ou de l autre de l ouverture découpée à travers le plancher ou à travers le mur A Profondeur de placard 24 61 cm B Dégag...

Страница 9: ...W10373101A 2011 All rights reserved Tous droits réservés 1 11 Printed in U S A Imprimé aux É U ...