Electric Dryer Installation Instructions

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

WED94HEX, WED95HEX,  
WED97HEX, WEDXXHEX

Electrical

This dryer requires a 3 or 4 wire, single 

phase, 120/240 volt, 60 Hz., AC only electrical supply 

(or 3 or 4 wire, 120/208 volt electrical supply, if speci-

fied on the serial/rating plate) on a separate 30-amp 

circuit, fused on both sides of the line. A time-delay 

fuse or circuit breaker is recommended. Connect to 

an individual branch circuit. Do not have a fuse in the 

neutral or grounding circuit.

Water

 

(Steam models only)

The dryer must be  

connected to the cold water faucet using new inlet 

hoses. Do not use old hoses. Do not overtighten.  

Damage to the coupling can result.

Exhaust venting

Exhaust your dryer to the outside. 

4" (102 mm) diameter vent is required. Rigid or flexible 

metal exhaust vent must be used. Do not use plastic  

or metal foil vet. Exhaust hood must be at least  

12" (305 mm) from the ground or any object that  

may be in the path of the exhaust.

Hood styles: A & B are recommended.

   

4"

(102 mm)

2½"

(64 mm)

     

4"

(102 mm)

      

4"

(102 mm)

B

A

A. Louvered hood  
B. Box hood 
C. Angled hood (acceptable) 

C

Dryer dimensions

Select the route that will provide the straightest and most direct path outdoors.  

 

Plan the installation to use the fewest number of elbows and turns.  

 

Use the fewest 90° turns possible.

Because Whirlpool Corporation policy includes a continuous commitment to improve 

Dimensions are for planning purposes only. For complete details, see Installation 

our products, we reserve the right to change materials and specifications without notice. 

Instructions packed with product. Specifications subject to change without notice.

Ref. W10057363

08/2010

For closet installation, with a door, 

the minimum ventilation openings 

in the top and bottom of the door 

are required. Louvered doors with 

equivalent air ventilation openings 

are acceptable.

Do not use vent runs longer than specified in vent 

length chart.  

 

Determine the number of elbows you will need.

27"

(686 mm)

3

/

4

"*

(18 mm)

38

1

/

8

"

(968 mm)

31

1

/

8

"

(790 mm)

50

7

/

8

"

(1292 mm)

Left or 

right side 

exhaust

3

1

/

2

"

(89 mm)

10

1

/

8

"

(257 mm)

Electric

6

1

/

4

"

(159 mm)

29

7

/

8

"*

(759 mm)

3

1

/

2

"*

(89 mm)

6

1

/

8

"*

(156 mm)

14

3

/

8

"

(365 mm)

NOTE:

 Most installations 

require a minimum of 

5" (127 mm) clearance 

behind dryer for exhaust 

vent with elbow. See 

“Venting Requirements.”

34" min.

(864 mm)

1"

(25 mm)

5"

(127 mm)

24 in.

2

(155 cm

2

)

48 in.

2

(310 cm

2

)

3"

(76 mm)

3"

(76 mm)

1"

(25 mm)

Vent system chart

Number of 

90° elbows

Type  

of vent

Box/louvered

hoods

Angled  

hoods

1

4

3

2

0

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

64 ft. (20 m)

54 ft. (16.5 m)

44 ft. (13.4 m)

35 ft. (10.7 m)

27 ft. (8.2 m)

58 ft. (17.7 m)

48 ft. (14.6 m)

38 ft. (11.6 m)

29 ft. (8.8 m)

21 ft. (6.4 m)

The Vent system chart provides venting requirements 

that will help achieve best drying performance.

NOTE:

 Side and bottom exhaust installation have a 90° 

turn inside the dryer. To determine maximum exhaust 

length, add a 90° turn to the total number of elbows 

when referemcing the chart.

Front view:

Side view:

Back view:

Closet installation (dryer only):