background image

 

USER MANUAL 

 

 

90cm, 5 burners Gas hob 

 

AKC 950C/IX 

 

 

 

 

 

 

 

 

Содержание AKC 640

Страница 1: ...USER MANUAL 90cm 5 burners Gas hob AKC 950C IX ...

Страница 2: ...nt prevention regulations Make sure that air circulates freely around the appliance Poor ventilation creates a shortage of oxygen Use of a gas cooking appliance produces heat and moisture in the room in which it is installed Ensure that the room is well ventilated by keeping the air intakes open and in good working order or by installing an extractor hood with discharge pipe If the appliance is us...

Страница 3: ...ials used are environmentally compatible and recyclable Please make your contribution to conserving the environment by using the separate waste collection channels available Decommissioned appliances Appliances which are no longer used or usable are not worthless waste Through environment friendly disposal a number of materials used in the production of your appliance can be recovered Find out abo...

Страница 4: ...ion to the gas supply 7 Connection 7 Electrical connection 7 Replacing the power supply lead 8 Building into fitted kitchen units 8 Insertion and fixing 9 On base cabinet with door 9 On base cabinet with oven 9 Instructions for use 10 The hob control knobs 10 Dual triple flame version 11 Lighting the burners 11 For correct use of the hob 11 Cleaning and maintenance 12 General cleaning 12 Hob 12 Ig...

Страница 5: ...tage 89 336 relating to Electromagnetic Compatibility 90 396 relating to Gas Appliances 93 68 relating to the General Standards Technical Data BURNER TYPE MAX OUTPUT MIN OUTPUT G20 20mbar G30 28 30mbar KW KW Nozzle mm Cons M3 h Nozzle mm Cons g h Small Auxiliary burner 1 00 0 35 0 72 0 095 0 50 73 Medium Semi rapid Burner 1 75 0 65 0 97 0 167 0 65 127 Large rapid burner 3 0 1 0 1 15 0 286 0 85 218...

Страница 6: ...ning must be constructed so that it will not be obstructed from inside or outside or constructed close to the floor The opening is recommended to be on the side opposite to that on which the flue gases are discharged If it is not feasible to provide these openings in the room where the appliance is installed the necessary air may be taken from an adjacent room provided that this room is not a bedr...

Страница 7: ...aded nut fitting the gasket between the components as shown in the illustration The gaskets must comply with the local standards Screw the parts together without forcing fit the union so that it points in the direction required then tighten all parts Connection Make the connection to the gas system using a rigid metal pipe and regulation unions or with a stainless steel hose complying with the loc...

Страница 8: ...e switch must not break a contact in the yellow green earth wire The brown live wire connected to the L terminal of the terminal board must always be connected to the live wire of the power supply mains In all cases the power supply lead must be positioned so that it does not reach a temperature 50o C above the room temperature at any point One example of an ideal route is shown in the illustratio...

Страница 9: ...e of the hob as shown in the illustration on the right 3 Place the hob in the installation opening and push it down so that the hob is resting firmly on the cabinet as show in the illustration The side springs will hold it in place Installation options On base cabinet with door When constructing the cabinet suitable precautions must be taken to prevent contact with the casing of the hob which beco...

Страница 10: ...ets or extractor hoods must be at least 650 mm above the hob Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Instructions for use The hob control knobs The symbols on the control knobs mean the following no gas flow maximum gas flow Minimum gas flow All operating positions must be set between the maximum and minimum flow settings and never between the maximum setting and the closed position ...

Страница 11: ...0 seconds this time is necessary to heat up the thermocouple Fig 1 C and activate the safety valve which would otherwise cut off the gas flow Then check that the flame is even and turn the control knob to adjust the flame as required In the instance of a power cut place a flame near the burner and proceed as already described If the flame does not light after a few attempts check that the burner c...

Страница 12: ...caps and burner caps often with boiling water and detergent taking care to remove all deposits The hob pan stands can also be washed in a dishwasher For stubborn dirt use ordinary non abrasive detergents or specific commercial products We strongly advise you not to use scouring pads steel wool or acids Hob Clean the hob regularly with a soft cloth wet with lukewarm water and a little liquid deterg...

Страница 13: ...formance and safety the gas regulator taps must be greased periodically Periodic lubrication of the taps must only be carried out by qualified personel who must also be contacted if the appliance malfunctions Keep plastic oil or any other flammable material away from the hob Warranty conditions Your new appliance is covered by a warranty The warranty conditions are provided in full in the Warranty...

Страница 14: ...ot open or totally open Make sure the valve is totally open Gas pipe There may be air in the gas pipe Make ignition repeatedly until it catches fire Burner cap The burner cap is not placed correctly Replace the burner cap Some holes in the lid are stocked Clean the holes of the lid Spark pin The spark pin is wet or contaminated by the food Dry the spark pin and clear away the food Gas connecting p...