Technical data

Regenerating valve

Voltage

220/ 240 V

Frequency

50/ 60

Hz

Resistance

3.13

k

Motor Diverter Valve

Voltage

220 - 240 V

Frequency

50/ 60

Hz

Resistance

6.5

k

Signal (2x within ~13 sec.) 5.0

V

Coil of dispenser

Voltage

220/ 240 V

Frequency

50/ 60

Hz

Resistance

1.3

k

Reed contacts

flow meter
salt control
rinse aid control

Optical water indicator (OWI)

Optical measurement of the water in sump
Combination part of:
Turbidity sensor

(DON)

Thermostat temp. sensor (notice NTC)

NTC

20 ˚C

58.1

k

25 ˚C

47.1

k

30 ˚C

38.2

k

40 ˚C

25.4

k

50 ˚C

17.2

k

60 ˚C

11.8

k

70 ˚C

8.3

k

80 ˚C

6

k

85 ˚C

4

k

Regeneration

Volume

300

cm

3

Position 0
after wash cycles

12

water hardness

0 - 5

˚dh

0 - 0.9

mmol/l

0 - 9

˚Fh

Position 1
after wash cycles

10

water hardness

6 - 10

˚dh

1 - 1.8

mmol/l

10 - 18

˚Fh

Position 2
after wash cycles

7

water hardness

11 - 15

˚dh

1.9 - 2.7

mmol/l

19 - 27

˚Fh

Position 3
after wash cycles

5

water hardness

16 - 21

˚dh

2.8 - 3.7

mmol/l

28.37

˚Fh

Position 4
after wash cycles

3

water hardness

22 - 28

˚dh

3.8 - 5.0

mmol/l

38 - 50

˚Fh

Position 5
after wash cycles

2

water hardness

29 - 35

˚dh

5.1 - 6.3

mmol/l

51 - 63

˚Fh

Position 6
after wash cycles

1

water hardness

36 - 60

˚dh

6.4 - 10.7 mmol/l
64 - 107

˚Fh

Salt consumption
for regeneration

77

g

Number of cycles
with 2 kg salt

26

Accesory

If you need spare parts apart from the spare
part list have a look in the
Service Bulletin 4812 718 40084.

Содержание ADG 8966 IXM

Страница 1: ...ed view 7 8 Circuit diagram 9 Program diagram 10 Text Legend 11 17 Family BIG VBL HIGH 6 Sensor 2 Service Manual Dishwasher integratable ADG 8966 IXM ADG 8966 IXM This documentation is only intended for qualified technicians who are aware of the respec tive safety regulations Date 30 10 2003 Subject to modification Document No 4812 718 19569 ...

Страница 2: ...Delay function Program information Start indicator Pre wash Main wash Drying End All programs will be locked after start Changing the program or finishing the program will be possible only after pressing the start button for longer then 1 5 sec Break by customer A switching off the appliance or unplug the appliance for a while this will frozen the program step and later on the program continuos on...

Страница 3: ...nce be switched off If this will not be done then the next normal wash will be made with the frequency of the Service Test Program 30 30sec Flow rates Inlet volume Flow meter at 0 3 bar quantity 1 1 l min 208 lmp l Spray pump 45 65 l min Drain pump 16 l min Pump height max 1 1 m Inlet valve 4 l min Spray arm lower 33 l min Sprayarm upper 27 l min Shower top 8 l min Fan for drying Total 900 l min P...

Страница 4: ...C 25 4 kΩ 50 C 17 2 kΩ 60 C 11 8 kΩ 70 C 8 3 kΩ 80 C 6 kΩ 85 C 4 kΩ Regeneration Volume 300 cm3 Position 0 after wash cycles 12 water hardness 0 5 dh 0 0 9 mmol l 0 9 Fh Position 1 after wash cycles 10 water hardness 6 10 dh 1 1 8 mmol l 10 18 Fh Position 2 after wash cycles 7 water hardness 11 15 dh 1 9 2 7 mmol l 19 27 Fh Position 3 after wash cycles 5 water hardness 16 21 dh 2 8 3 7 mmol l 28 3...

Страница 5: ... INOX 303 1 4812 460 38132 Plate handle SIL 305 1 4819 502 18241 Screw synthetic 305 2 4819 505 18191 Nut 305 6 4812 440 10739 Batten SIL MET 331 0 4812 413 59133 Knob program cpl SILV Pos No 12NC Code Description 332 0 4812 410 28675 Button BK 332 1 4812 410 29028 Button IN 332 2 4812 410 28672 Button BK 350 1 4812 440 19781 Window BK 350 2 4812 381 28047 Lens 400 0 4812 361 58336 Motor SP 50Hz a...

Страница 6: ...281 28417 Flap non return 783 6 4812 530 28796 Hose 10x3x180 10 791 0 4812 532 68099 Gasket 791 2 4812 530 58093 Gasket 900 1 4812 310 28021 Fastener set not shown 901 0 4822 401 10258 Clamp hose 10 18 mm 901 1 4812 401 18424 Strap 050 0 901 2 4812 401 18157 Strap 32 50 9 C61 901 5 4812 401 48573 Strap 028 6 901 8 4812 401 18075 Strap 20 32 9 mm 902 1 4812 466 78015 Fastener f buildt in models 902...

Страница 7: ...S E R V I C E Whirlpool Europe ADG 8966 IXM 30 10 2003 Page 7 Customer Service 8542 966 10760 Doc No 4812 718 19569 Exploded view ...

Страница 8: ...S E R V I C E 30 10 2003 Page 8 ADG 8966 IXM Whirlpool Europe Doc No 4812 718 19569 8542 966 10760 Customer Service Exploded view ...

Страница 9: ...il high DVL Diverter ventil low FM Flow meter HEWI Heating IF Interference filter LS6 Water leakage switch L Line MS Main switch NTC Thermostat temp sensor N Neutral OWI Water indicator optical PRG Plug to program RV Water hardness switch RE2 Heating relay RR SA Reed relay salt RR RA Reed relay rinsaid SPM Sprayarm motor THS1 Safety thermostat THS 2 Fuse TBL Power supply terminal TL Winding protec...

Страница 10: ...S E R V I C E 30 10 2003 Page 10 ADG 8966 IXM Whirlpool Europe Doc No 4812 718 19569 8542 966 10760 Customer Service Program diagram ...

Страница 11: ...S E R V I C E Whirlpool Europe ADG 8966 IXM 30 10 2003 Page 11 Customer Service 8542 966 10760 Doc No 4812 718 19569 Text Legend ...

Страница 12: ...S E R V I C E 30 10 2003 Page 12 ADG 8966 IXM Whirlpool Europe Doc No 4812 718 19569 8542 966 10760 Customer Service Text Legend ...

Страница 13: ...S E R V I C E Whirlpool Europe ADG 8966 IXM 30 10 2003 Page 13 Customer Service 8542 966 10760 Doc No 4812 718 19569 Text Legend ...

Страница 14: ...S E R V I C E 30 10 2003 Page 14 ADG 8966 IXM Whirlpool Europe Doc No 4812 718 19569 8542 966 10760 Customer Service Text Legend ...

Страница 15: ...S E R V I C E Whirlpool Europe ADG 8966 IXM 30 10 2003 Page 15 Customer Service 8542 966 10760 Doc No 4812 718 19569 Text Legend ...

Страница 16: ...S E R V I C E 30 10 2003 Page 16 ADG 8966 IXM Whirlpool Europe Doc No 4812 718 19569 8542 966 10760 Customer Service Text Legend ...

Страница 17: ...S E R V I C E Whirlpool Europe ADG 8966 IXM 30 10 2003 Page 17 Customer Service 8542 966 10760 Doc No 4812 718 19569 Text Legend ...

Отзывы: