background image

Содержание AC0062XM0

Страница 1: ...AIRCONDITIONER Ovens Compactors Room Air Conditioners Dehumidifiers Automatic Washers Clothes Dryers Freezers Refrigerator Freezers Ice Makers Dishwa ...

Страница 2: ...perly maintained l Also remove energy label and buy guide Use damp cloth to take off any glue residue Do not use a sharp instrument or any harsh or abrasive cleaners Energy SavingTips l Improve home insulation seal doors windows and close fireplace flue l Close blinds or drapes on sunny side of house add window awnings l Keep air filter clean Don t block air flow with drapes or furniture l Ventila...

Страница 3: ...ibility and obligation of the customer to provide proper and adequate receptacle wiring installed by a qualified electri cian OBSERVE NATIONAL ELECTRICAL CODE AND ALL LOCAL GOVERNING CODES AND ORDINANCES Electrical Requirements A 115 volt 103 5 min 126 5 max 60 hertz AC only 15 ampere fused electrical supply is required time delay fuse or time delay circuit breaker required See Figure 1 on page 4 ...

Страница 4: ...NCES Do not under any circumstances remove the power supply cord ground prong RECEPTACLE WIRING RESEPTACLE WIRING should be at least as large as 14 gauge Use copper wire only It is the personal responsibility and obligation of the customer to provide proper and adequate receptacle wiring installed by a qualified electri cian OBSERVE NATIONAL ELECTRICAL CODE AND ALL LOCAL GOVERNING CODES AND ORDINA...

Страница 5: ...ORDINANCES Do not under any circumstances remove the power supply cord ground prong ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE A three wire single phase 60 hertz AC only electrical supply is required A separate electrical supply is required on a separately fused circuit Do not fuse ground neutral See Chart C for receptacle voltage requirements proper fuse size wire size and wiring connec tion...

Страница 6: ...n meth od for slid out chassis model only 1l Unpack accessory parts see Figure 5 before installing your air conditioner A normal installation can be made with a screwdriver small level pocket knife tape measure and a drill with 3 32 drill bit Am Pick the right window First decide what room s you want to cool Then choose a window that will allow the air conditioned air to flow freely and directly i...

Страница 7: ...e proper slope is designed into the product However be sure you have approximately a one half bubble X downward tilt to the outside for proper water drainage see Figure 9 If necessary reposition or shim cabinet to provide the proper tilt or side to side leveling Figure IQ 6 Pull out sliding curtains while holding air conditioner in window Extend curtains on both sides until they engage window chan...

Страница 8: ...your air conditioner A normal installation can be made with a screwdriver saw small level pocket knife tape measure and drill with 3 32 drill bit Figure 12 4 SHEET 7 S HEET 5 WooD PLASTIC DRAIN CUP METAL SCREWS METAL SCREWS SCREWS SPOUT S 3XWe aloX1 2 8X3 4 ROUND HEAD HEX HEAD ROUND HEAD 2l Pick the right window First decide what room s you want to cool Then choose a window that will allow the air...

Страница 9: ...ng st strip or window side of bottom flange Now starting at the lower corner of the cabinet apply seal strips over the center line of the pre drilled holes for one of the side mounting angles over the center line of pre drilled holes for the top mounting channel and over the center line of pre drilled holes for the other side mounting angle See Figure 16 Figure 16 b 6a Attach side mounting angles ...

Страница 10: ...wn in Figure 19 i e along the bottorn edge and window channel edge Also place a seal strip along the top outside edge of each filler board Now attach the filler boards to the side mounting angles with four 3 8 round headed sheet metai screws Tighten the screws only loosely so the filler boards can be moved back and forth 9 Insert side mounting slides all the way into top mounting channel 10 Place ...

Страница 11: ...E AIR CONDITIONER DOES NOT FALL OUT OF WINDOW REMOVE BRACKET ONLY WHEN YOU WISH TO REMOVE AIR CONDITIONER FROM WINDOW Seal small openings around installation with gum type sealer installed where this is undesirable you can direct the water to a more suitable spot by simply attaching a 5 8 inside diameter thin walled hose to the drain spout at rear of cabinet l Insert air conditioner into cabinet D...

Страница 12: ...e room side of the cabi net Your choice affects the finish frame alignment with the inside wall When using a wood metal or plastic molding the finish frame should almost line up with the inside wall If the wall is plastered to the cabinet and no molding is used the finish frame must be set into the wall by l 2 see Figure 25 for frame construction or Figure 26 for brick veneer construction Cut thro...

Страница 13: ...wo screws for the top not included Do not overtighten screws or cabinet will distort and provide a poor air seal between cabinet and unit 11l Insert air condttioner into cabinet Do not push against sharp fins and plastic parts Attach green ground wire to the left front corner of unit base by using retainer screw CAUTION KEEP WIRE CONNECTED WHENEVER AIR CONDITIONER IS IN CABINET IT IS THERE FOR YOU...

Страница 14: ...RESH AIR Adjust fan control to FAN ONLY FRESH AIR FAN ONLY l For Exhaust Controls With 3 To circulate room air EXHAUST and FRESH AIR Settings Set exhaust control to OFF Adjust control to FAN ONLY 1l To exhaust room air Set exhaust control to EXHAUST Adjust fan control to speed desired Set thermostat on l if no cooling is desired EXHAUST OFF FAN ONLY 15 ...

Страница 15: ...d FRESH AIR Settings 1l To exhaust room air Set exhaust control to EXHAUST Adjust fan control to speed desired Set thermostat on l if no cooling is desired EXHAUST LO COOL l 2l To bring in outside air Set exhaust control to FRESH AIR Adjust fan control to FAN ONLY Set exhaust control to OFF Adjust fan control to FAN ONLY OFF FAN ONLY 15 ...

Страница 16: ...r to direct air On some models all louvers are fixed The louvers can not be adjusted Cleaningand Caring For Your Air Conditioner roper use and care of your air conditioner will lelp insure longer life and lower operating costs Fol ow these instructions carefully Call your dealer for an annual checkup Cleaningof Front Panel 1 Remove the front panel from unit when cleaning Press down at top edge of ...

Страница 17: ...ns collect dirt sand leaves insects or algae Also clean if you detect an odor from the air conditioner While the cabint is open this is a good time to oil the fan motor Remove plastic film from motor and electrical parts Replace unit in cabinet NOTE It s a good idea to wait 24 hours before starting the unit again This allows time for all areas to dry out The water from rainfall or from normal oper...

Страница 18: ... more westerly exposure 4 From this point read down to bottom of chart to determine required Btu hr output Write the Btulhr figure in the space indicated below 5 Btu hr from number 4 above 5 Locate your geographic area on inset map and multiply factor shown by figure in number 5 7 If room air conditroner is intended primarily for night time cooling subtract 30 from figure in number 6 a Subtract 30...

Страница 19: ...rvice ISnecessary recommend a qualified service company In your area 3 If you need service r 3 T 1 01 7Ei CAkv FRANCHISED SERVICE Whirlpool has a nation wide network of franchised TECH CARE Service Companies TECH CARE service technicians are trained to fulfill the product warranty and provide after I warranty service anywnere in the United States To locate TECH CARE service in your area Call our C...

Страница 20: ...oner caused by accident misuse fire flood acts of God or use of products not approved by Whirlpool D The removal and reinstallation of the air conditioner if it is installed in an overhead or other inaccessible location or not installed in accordance with published installation instructions Service under the full warranties must be provrded by a franchised TECH CARE service company WHIRLPOOL CORPO...

Отзывы: