PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

VENTING REQUIREMENTS

MH1160XS
MH1170XS

MH2175XS

Electrical:

A 120-volt, 60 Hz, AC-only, 15 or 20

amp electrical supply located in the upper cabinet
as close as possible to the microwave oven hood.
A time-delay fuse or circuit breaker and separate
circuit is recommended.

®

Microwave Hood Combination

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.

Ref. 8206555

05-30-06

Recommended standard fittings

If the existing vent is round, a rectangular-
to-round adapter must be used and a
minimum 3" (7.6 cm) clearance must exist
between the top of the microwave oven and
the rectangular to round transition piece so
that the damper can open freely and fully.

1 - 3-1/4" x 10" (8.3 x 25.4 cm)

90° elbow

= 25 ft. (7.6 m)

1 - wall cap

= 40 ft. (12.2 m)

8 feet straight

=   8 ft. (2.4 m)

Length of 
3-1/4" x 10" system 

= 73 ft. (22.2 m)

6" (15.2 cm) vent system

3-1/4" x 10" (8.3 x 25.4 cm) vent system

A. 1 - transition

=   5 ft. (1.5 m)

B. 2 - 90° elbows

= 20 ft. (6.1 m)

C. 1 - wall cap

= 40 ft. (12.2 m)

8 feet straight 

=   8 ft. (2.4 m)

Length of 6" system 

= 73 ft. (22.2 m)

A

A.

B

C

A

B

B.

6 ft.

(1.8 m)

2 ft.

(0.6 m)

2 ft.

(0.6 m)

6 ft.

(1.8 m)

3-1/4" x 10" 
to 6" = 5 ft.

3-1/4" x 10" 
roof cap = 24 ft.

3-1/4" x 10" 
90

°

 elbow = 25 ft.

90

°

 elbow 

6" = 10 ft.

3-1/4" x 10" 
wall cap = 
40 ft.

3-1/4" x 10" 
flat elbow = 
10 ft.

45

°

 elbow 

6" = 5 ft.

Recommended vent length

A 3-

¹⁄₄

" x 10" (8.3 x 24.5 cm) rectangular or 6" (15.2 cm)

round vent should be used. The total length of the vent
system including straight vent, elbow, transitions, wall or
roof caps must not exceed the equivalent of 140 feet 
(42.7 m) for either type of vent. For best performance, use
no more than three 90° elbows. To calculate the length of
system you need, add the equivalent feet for each vent
piece used in the system. See examples below.

NOTE: 

There must be

at least one wall stud
within cabinet
opening.

Roof venting

Wall venting

roof cap

3-1/4" x 10" 

through-the-roof

3-1/4" x 10" 

through-the-wall

wall cap

CABINET OPENING DIMENSIONS

For wall or roof venting methods: 

If the wall exhaust method is chosen, be sure that
there is proper clearance within the wall for the
exhaust vent.

Wall and roof caps must have back-draft damper. 
We recommend:

using rigid metal vent.

that length of vent and number of elbows should
be kept to a minimum to provide efficient
performance.

that size of vent should be uniform.

using duct tape to seal all joints in the vent
system.

using caulking compound to seal exterior wall or
roof opening around cap.

two elbows should not be installed together.

We do NOT recommend:

flexible metal vent.

NOTE:

If flexible metal vent must be used, calculate

each foot of flexible metal vent as two feet of rigid
metal vent. Flexible metal elbows count twice as
much as standard elbows.

66" (167.6 cm)
minimum from

floor to top of

wall mounting

plate.

30" (76.2 cm) typical from bottom edge of
upper cabinet frame or, if frameless, from
cabinet's exterior bottom surface to cooking
surface. 

Space between cabinets must be 30" (76.2 cm)
minimum and be free of obstructions. 

12" to 14" (30.5 to 35.6 cm)
cabinet depth recommended

29

⁷⁄₈

" (75.9 cm

)

15

³⁄₈

"

(39.1 cm

)

17

¹⁄₈

"

(43.5 cm)

15

⁷⁄₈

"

(40.3 cm)