WHIRLPOOL CONSUMER SERVICES
Models 6ADP905/3 WH
Page 19 of 19
CONTROL BOARD TEST POINTS
A pair of long, wire claw type probes are required to access the test points.
Checking voltages at the test points will determine the correct operation of the function push
buttons and the rotary switch.
Before
attaching test probes to the control board test points which are accessed via the
control board service window, disconnect the dishwasher from the supply. Short circuiting of
any of the electronic components will cause the control board to fail.
Test Points :
T0 = Common
T2 = Analogue voltage
T1 = Analogue voltage
T3 = Digital signal
T0
T3 T2
T1
Control Board
A voltmeter with a high input impedance is required to measure the control board voltages.
The degree of agreement between the measured voltage and the nominated voltage will be
dependent on the accuracy of the voltmeter.
Test Point T0 to T1
Communication between control board and display board
Push Button Voltage (V dc)
All off
-5.24
Test Point T0 to T2
Communication between control board and user board
Rotary Switch Voltage (V dc)
O
0.00
Program 1
Cold
-1.32
Program 2
50°C
-2.90
Program 3
65°C
-3.36
Program 4
65°C
-3.80
Program 5
70°C
-4.27
Test Point T0 to T3
Communication between control board and display board
Before Start (LED off)
-5.24 V dc
After Start (LED on)
-3.87 V dc
Service Window
Содержание 6ADP905/3 WH
Страница 2: ...WHIRLPOOL CONSUMER SERVICES Models 6ADP905 3 WH Page 2 of 19 BLANK PAGE ...
Страница 6: ...WHIRLPOOL CONSUMER SERVICES Models 6ADP905 3 WH Page 6 of 19 EXPLODED VIEW CABINET ...
Страница 7: ...WHIRLPOOL CONSUMER SERVICES Models 6ADP905 3 WH Page 7 of 19 EXPLODED VIEW DOOR AND CONTROL PANEL ...
Страница 11: ...WHIRLPOOL CONSUMER SERVICES Models 6ADP905 3 WH Page 11 of 19 PROGRAM CHART ...