background image

WHIRLPOOL CONSUMER SERVICES             

 

Models 6ADP905/3 WH

Page 12 of 19

CIRCUIT DIAGRAM

C1

Capac

itor

CB

Cont

rol

 board

DB

 Di

sp

la

board

DUB

D

is

pl

ay and Us

er board

D

LB 

T

im

er

 sw

itch

 D

el

ay

DP

M

 Drai

n pum

p M

ot

or

DO Cl

eani

ng 

agent

 dos

age

DR 

Fi

nal

 ri

ns

e dos

ag

e

D

S

 D

oo

sw

itch

FM

 Flow

 m

eter

HE

W

I Heat

in

g

IF

 I

nt

erf

erenc

fil

ter

L.

S

6 W

at

er 

leak

age 

sw

itdl

L Li

ne

MS

 Ma

in

 s

w

itc

h

NTC Therm

os

tat

 t

em

p.

 s

ens

or

N Neut

ral

RE

2 Heat

ing rel

ay

RR RA

 Reed rel

ay ri

ns

e ai

d

SPM

Sp

ra

y p

um

p m

oto

r

THS

1S

af

et

y t

herm

os

tat

TH

S 2 Fus

e

TB

P

ow

er s

uppl

y t

erm

inal

TL W

indi

ng 

prot

ec

tive 

cont

ac

t

UB

 Us

er 

board

Vv

V1

 W

ate

r in

le

t v

alv

e

WI

 Wa

te

in

di

ca

to

r

00 bl

ac

k

66 bl

ue

88 grey

99 w

hi

te

Connec

to

r Ras

t 2.

5 on CB

:

Red m

ark

  :

 le

ft

 hand s

ide

B

lac

k m

ark

: ri

ght

 hand s

ide

Содержание 6ADP905/3 WH

Страница 1: ...pool Australia Pty Limited Whirlpool is a registered trademark of Whirlpool U S A This documentation is intended only for qualified technicians who possess the required qualifications and are aware of the regulatory requirements applicable to servicing electrical appliances Whirlpool Australia Pty Limited Part No SM4015 A B N 28 003 578 023 WHIRLPOOL AUSTRALASIA CONSUMER SERVICES SERVICE MANUAL DI...

Страница 2: ...WHIRLPOOL CONSUMER SERVICES Models 6ADP905 3 WH Page 2 of 19 BLANK PAGE ...

Страница 3: ...ABINET 6 EXPLODED VIEW DOOR AND CONTROL PANEL 7 SPARE PARTS LIST 8 10 PROGRAM CHART 11 CIRCUIT DIAGRAM 12 PROGRAM SEQUENCE AND INDICATION 13 PROCEDURE FOR DIAGNOSTIC SERVICE TEST PROGRAM 13 PASSIVE TEST PROGRAM 14 FAULT CODES DISPLAY 15 FAULT DIAGNOSIS 16 17 ACTIVE TEST PROGRAM 18 CONTROL BOARD TEST POINTS 19 ...

Страница 4: ...41mm Note To measure the water level remove the coarse sieve and using a ruler measure the water depth from the bottom of the sump Detergent max Pre wash 10 cm3 Main wash 45 cm 3 Rinse aid 125 ml 6 Dosage steps 1 6 ml Operating Speeds Spray pump motor 2800 rpm Drain pump motor 3000 rpm Spray arm lower 20 40 rpm Spray arm middle 25 35 rpm Spray arm upper 45 65 rpm Water Pressure Temperature Inlet p...

Страница 5: ...erature on surface 115 ºC Double safety element cut out self resetting 85 ºC Potentiometer Between 1 Black and 2 Middle Position 0 0 0 kΩ Position 1 0 5 kΩ Position 2 1 0 kΩ Position 3 1 4 kΩ Position 4 1 8 kΩ Position 5 2 3 kΩ Position 6 2 6 kΩ Water Valves Single Valve at Inlet Hose Voltage 230 240 V Frequency 50 60 Hz Resistance 3 8 k Dispenser Coil Voltage 230 240 V Frequency 50 60 Hz Reed Con...

Страница 6: ...WHIRLPOOL CONSUMER SERVICES Models 6ADP905 3 WH Page 6 of 19 EXPLODED VIEW CABINET ...

Страница 7: ...WHIRLPOOL CONSUMER SERVICES Models 6ADP905 3 WH Page 7 of 19 EXPLODED VIEW DOOR AND CONTROL PANEL ...

Страница 8: ...887 Plinth WH 061 0 4812 466 88455 Counter weight 103 0 4812 440 18978 Door outer 120 0 4812 440 19456 Door inner 120 1 4812 440 18969 Batten 130 0 4812 417 58361 Tilt lock complete WH 131 0 4812 401 18416 Hook lock 191 0 4812 466 68564 Gasket door 192 0 4812 466 68467 Gasket door lower 241 0 4812 458 18913 Basket upper straight 241 1 4812 458 18324 Holder cups right WH 241 2 4812 535 78036 Bearin...

Страница 9: ...7 Strain relief 521 0 4812 214 78238 Control board CB 571 0 4812 281 28379 Valve inlet 583 0 4812 271 28407 Switch diaphragm 620 0 4812 218 38056 User board UB 633 0 4812 271 38355 Microswitch door 680 0 4812 418 68155 Combidosage 680 1 4812 466 68495 Gasket combidosage 681 1 4812 466 68497 Gasket combidosage 681 2 4812 440 18975 Flap combidosage 682 0 4812 466 68496 Gasket combidosage 691 0 4812 ...

Страница 10: ...se to drain trap spigot 781 2 4819 492 68405 Clip non return valve drain hose 781 3 4812 281 28364 Flap non return valve drain hose 783 4 4812 530 28904 Hose 10x3x265 10 783 5 4812 530 78028 Distributor hose 783 6 4812 530 28824 Hose 10 3X3X245 791 0 4812 532 68067 Gasket sump to cavity 791 4 4812 466 68503 Gasket pressure switch to sump 791 5 4812 466 68504 Gasket NTC 794 1 4819 530 58032 Gasket ...

Страница 11: ...WHIRLPOOL CONSUMER SERVICES Models 6ADP905 3 WH Page 11 of 19 PROGRAM CHART ...

Страница 12: ...h FM Flow meter HEWI Heating IF Interference filter L S6 Water leakage switdl L Line MS Main switch NTC Thermostat temp sensor N Neutral RE2 Heating relay RR RA Reed relay rinse aid SPM Spray pump motor THS1Safety thermostat THS 2 Fuse TBL Power supply terminal TL Winding protective contact UB User board VvV1 Water inlet valve WI Water indicator 00 black 66 blue 88 grey 99 white Connector Rast 2 5...

Страница 13: ...onent connector must be connected to the control board to load the electronic device 4 If the dishwasher appears totally dead perform test point tests See Page 19 5 After completion of any repair run the test program again to confirm repairs have been effective NOTE 1 The first step with test the program of the new service control boards is without backrinsing Therefore if the machine contains any...

Страница 14: ... fault All Other Fault codes located during normal operation are stored by the machine and will be displayed by the passive test PASSIVE TEST PROGRAM Passive test program will indicate the mode of Start failure If there is no failure the test program will result in PS1 to PS4 flashing sequentially Starting the Passive Test Program PS1 PS4 1 Turn the program selector to the off Flash sequentially O...

Страница 15: ...isplayed after the Active Test Program is run F7 Flow Meter Failure F8 Water Level Failure F9 Water Inlet Valve Open Continuously LED Flashing LED Off PS1 PS2 PS3 PS4 START PS1 PS2 PS3 PS4 START PS1 PS2 PS3 PS4 START PS1 PS2 PS3 PS4 START PS1 PS2 PS3 PS4 START PS1 PS2 PS3 PS4 START PS1 PS2 PS3 PS4 START PS1 PS2 PS3 PS4 START PS1 PS2 PS3 PS4 START PS1 PS2 PS3 PS4 START PS1 PS2 PS3 PS4 START PS1 PS2...

Страница 16: ... defective open circuit Spray pump is not working F4 Draining Failure Drain pump energised and after four minutes Water Indicator WI still detects water Drain pump DPM defective Drain hose blocked Control board defective Water Indicator defective Pressure switch contacts remain closed F5 Spray Arm Blocked Fault does not cause dishwasher to stop SAB sensor sends less than 10 pulses minute SAB senso...

Страница 17: ...ive F8 Water Level Failure Spray pump motor is energised and water indicator switches to low level more than 20 times in two minutes Water indicator defective switch should operate when machine contains approximately one litre of water Sieve blocked Severe foaming Item in wash load has turned over and filled with wash water Spray pump pressure unstable F9 Continuous Water Inlet Water Inlet valve i...

Страница 18: ... if the heat cycle is bypassed the test runs for approximately 3 minutes and 45 seconds The active test program runs to the point of failure then stops If there is no failure the test programs runs to the end The failure position is indicated by the flashing START LED extinguishing To exit the test program press the START button for more than three seconds An empty rinse aid container will not cau...

Страница 19: ...Analogue voltage T1 Analogue voltage T3 Digital signal T0 T3 T2 T1 Control Board A voltmeter with a high input impedance is required to measure the control board voltages The degree of agreement between the measured voltage and the nominated voltage will be dependent on the accuracy of the voltmeter Test Point T0 to T1 Communication between control board and display board Push Button Voltage V dc ...

Отзывы: