background image

P84341 A 

Sheet 1 of 4 

 

273 Branchport Avenue 
Long Branch, NJ  07740 
(800)  631-2148                          

Thank you for using our products.

 

www.wheelockinc.com 

INSTALLATION INSTRUCTIONS 

SAFE

PATH

®

4

 C.O. Port Adapter 

SP-COA 

 

Use this product according to this instruction manual.  Please keep this instruction manual for future reference. 

 

GENERAL: 

Wheelock's 

SAFE

PATH

®

4

 

C.O. Port Adapter (SP-COA) is used when connecting between an unused C.O. Port and the SP40/2 

Telephone (TEL) input.  
 
The unit is attractively packaged for wall mounting.  The SP-COA requires connection to a 24VDC filtered and regulated power 
supply, which supplies power to the unit and talk battery for the unused C.O. Port.  Two wires are connected from the unused C.O. 
Port to the telephone input (TEL INPUT) terminals on the SP-COA.  The telephone output (TEL OUTPUT) is then connected to the 
telephone input (TEL) connections on the SP40/2 motherboard.  See Figure 2. 

 

NOTE:

  All 

CAUTIONS

 and 

WARNINGS

 are identified by the symbol 

.  All warnings are printed in bold capital letters. 

 

WARNING:  PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THIS PRODUCT.  FAILURE 

TO COMPLY WITH ANY OF THE FOLLOWING INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN 
IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY 
SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU 
AND/OR OTHERS. 

 

INSTALLATION INFORMATION: 

 

WARNING:  DO NOT CONNECT AC POWER OR BATTERY BACKUP POWER UNTIL SYSTEM WIRING HAS 

BEEN CONNECTED OR THE SP-COA HAS BEEN MOUNTED, AND FIELD WIRING HAS BEEN INSPECTED. 

 

Connect the SP-COA TEL INPUT to the unused C.O. Port or a stand-alone telephone.  Connect the SP-COA TEL OUTPUT to the 
TEL terminals on TB5 on the SP40/2.  Connect the SP-COA POWER terminals to a 24VDC filtered and regulated power supply 
(Wheelock’s part number RPS-2406 is recommended).  See Figure 1 for details. 
 
 

Figure 1: 

 

SP-COA

24V INPUT

  TEL 

INPUT

    TEL 

OUTPUT

+

-

+

-

+

-

UNUSED CO

RPS-2406

-

+

-

+

SP40/2

+

-

PORT OR

TELEPHONE

STAND ALONE

  TEL 

INPUT

 

 
 

 
Copyright 2002 Wheelock, Inc.  All rights reserved. 

Содержание SAFEPATH SP-COA

Страница 1: ...NS and WARNINGS are identified by the symbol All warnings are printed in bold capital letters WARNING PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THIS PRODUCT FAILURE TO COMPLY WITH ANY OF THE FOLLOWING INSTRUCTIONS CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION INSTALLATION AND OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION WHICH COULD RESULT IN PROPERTY DAMAGE AND...

Страница 2: ...propriate terminals with a small screwdriver and insert the bare wire into the wire hole Release the tab to securely clamp the wire Plug in AC power cord for the 24VDC power supply Check page activation by operating the page system SPECIFICATIONS Table 1 Input Specifications Output Specifications Input Voltage 24VDC Input Current Standby 002 Amps Input Current Page 049 Amps Telephone Input Level 5...

Страница 3: ...fy SP COA has released from last page Check the SP40 2 is not in a trouble condition Verify that Tel Input and Tel Output wires are not switched 2 No sound or low page volume Check for presence of audio on the Tel Input terminals Increase the Tel volume control on the SP40 2 see SP40 2 manual for information and location of the Tel volume control Check the SP40 2 is not in a trouble condition ...

Страница 4: ...Y AGAINST DAMAGE RESULTING FROM MISAPPLICATION IMPROPER SPECIFICATION ABUSE ACCIDENT OR OTHER OPERATING CONDITIONS BEYOND WHEELOCK S CONTROL SOME WHEELOCK PRODUCTS CONTAIN SOFTWARE WITH RESPECT TO THOSE PRODUCTS WHEELOCK DOES NOT WARRANTY THAT THE OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR FREE OR THAT THE SOFTWARE WILL MEET ANY OTHER STANDARD OF PERFORMANCE OR THAT THE FUNCTIONS OR ...

Отзывы: