Wheelock PS-33A Скачать руководство пользователя страница 1

P81186 F 

Sheet 1 of 2 

 

273 Branchport Avenue 
Long Branch, NJ  07740

 

(800) 

 

631-2148            

 

 

 

 

 

Thank you for using our products.

 

www.wheelockinc.com 

INSTALLATION INSTRUCTIONS 

TELSTROBE  

 

Use this product according to this instruction manual.  Please keep this instruction manual for future reference. 

 

MODEL:  PS-33A 

 

GENERAL: 

The TelStrobe is a self contained, plug-in strobe signal that emits a high intensity flashing light when the telephone rings.  A minimum 
one second ring time is required for the ringing voltage to produce one to two strobe flashes per second. 

 

In the event of a malfunction with this product, repairs will be performed by Wheelock Inc., or its authorized agents in accordance 
with Wheelock's published Terms and Conditions of Sale. 

 

READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THIS PRODUCT. 
NOTE:

  All 

CAUTIONS

 and 

WARNINGS

 are identified by the symbol

 

.  All warnings are printed in bold capital letters. 

 

MOUNTING INFORMATION: 

The TelStrobe is designed for mounting to interior structures such as walls, partitions or posts.  Locate the TelStrobe as desired for 
visibility and connect it as shown in the sketch below.  Note that the special mounting screws supplied with each unit must be spaced 
as indicated.  The TelStrobe hangs securely on the screw heads by means of key holes on the back of the unit.  Connect a standard 
modular telephone line cord (not supplied) from the jack on the strobe to the ring voltage supply.  Refer to figure below for proper 
installation.  The TelStrobe is now ready to operate.  Test the installation by having someone ring your number to make sure that the 
strobe flashes properly. 
 

SPECIFICATIONS: 

 

Table 1:  Performance Specifications 

Model Number 

PS-33A WPW 

Input Voltage Range 

18-30VAC/VDC 

Nominal Voltage 

24VAC/DC 

Current Draw at Nominal Voltage 

.150A 

Peak Candlepower (cp) 

25,000 

Nominal Flash Rate 

2/Second 

Input Jack 

USOC RJ11C 

 

BLACK

RED

GREEN

YELLOW

NOT USED

SYSTEM RING

TO COMMUNICATION

SIGNAL SUPPLY

POLARITY IS REVERSED.

NOT POLARITY SENSITIVE,

WILL FUNCTION EVEN IF

NOTE

MODULAR JACK

(6 POSITION)

MODULAR PLUG

2 PAIR MODULAR LINE CORD

 

2"

 

Figure 1:  TelStrobe 

Figure 2:  Mounting Template 

 

Copyright 2002 Wheelock, Inc.  All rights reserved. 