58kHz SKY-GUARD

TM 

INSTALLATION 

MANUAL 

 

 

 

 

WG SECURITY PRODUCT INC. 

 

 

 

 

 

 

 

3031 Tisch Way #602    San Jose, CA 95128 USA 

Tel: 408-241-8000   Fax: 408-241-8082 

For Tech Support In Your Country Please Visit Our Web Site 

www.wgspi.com

 

Содержание SKY-GUARD

Страница 1: ...z SKY GUARDTM INSTALLATION MANUAL WG SECURITY PRODUCT INC 3031 Tisch Way 602 San Jose CA 95128 USA Tel 408 241 8000 Fax 408 241 8082 For Tech Support In Your Country Please Visit Our Web Site www wgspi com ...

Страница 2: ...EDURES P5 QUICK START INSTRUCTIONS P7 PROBLEMS P7 ACCESSORIES P7 SECTION THREE APPENDIX IR CONTROL KEYBOARD FUNCTION DESCRIPTION KEY DEFINITIONS DEFAULT PARAMETERS TABLE P8 FLOW CHART OF SUGGESTED TUNING PROCEDURES P9 TUNING INSTRUCTIONS P10 PARAMETERS CONFIGURATION P12 SECTION FOUR IMPORTANT SAFEGUARDS AND REGULATORY NOTICES P16 ...

Страница 3: ...nstantly change its phase to accommodate the environment that it protects The Sky GuardTM system is software driven EAS system that works in combination with any 58KHz tags and labels The system s transmitter sends out 58Khz signals exciting tags within the detection zone and the system receiver listens for the unique signal that any 58KHz tags and labels produce and the sequence produced is then ...

Страница 4: ...lectronics Other manufacturers need professional technicians to tune the system to ensure proper functioning But once the environment condition changes the systems best working position changes and requires tuning again The Sky GuardTM system benefiting from its fully digital electronics constantly detects the environment automatically adapts to any changes It will always operate at its optimum pe...

Страница 5: ...e more detecting antennas shall be installed The system can be mounted on either side of doorway The Sky GuardTM can be installed close to a metal door or frame with out decreasing the detection range but once the material or environment around door entry changes the system need to be reset to adjust the inductance of transmitter We also recommend that the when using a neon light the system is kep...

Страница 6: ...Page 4 Parts List For simple installation Tx loop 9 m Antenna holders 4 sets System 1 with build in alarm indicator Passive antenna 3 sets System open picture ...

Страница 7: ...Page 5 Installation Procedures 1 First loop the TX loop according to the outline of the gate frame 2 Open the system housing and mount the system on the one side of the gate as the diagram shows ...

Страница 8: ...ections are ready with the system when out of box but if expansion of the power line is needed the termination can be connected as the above diagram shows The left terminal is for power line grounding and the right terminal is for power line N and L terminations N and L can be swapped 6 Finally when all the connections ready mount the housing onto the system and fix it by screwing down the screws ...

Страница 9: ...guration accomplished three beeps of short term intervals indicate that the system is ready for tag detections Problems If you ensure every step of the installation is proper all the connections are correct and the system still malfunctions or does not work with satisfactory sensitivity please call our technical support number 408 530 8070 Accessories A noise shield is available to cover the elect...

Страница 10: ...GMXVWPHQW 6 FKURQ GMXVWPHQW WR 5HFHLYLQJ LQGRZ HOD WR ODUPLQJ 6RXQG 9ROXPH RQWURO QRW DGMXVWDEOH QRQH 0LQXPXP 6LJQDO GMXVWPHQW WR RQILJXUDWLRQ RDGLQJ 0RGH 6HWWLQJ RU EODQN WGSPI Strongly recommends using the Self Tuning Mode when installing the system for the first time please see H entry for instructions on how to operate this feature ...

Страница 11: ...ew noise or less value than 80 Adjust Gain increase slightly if False Alarms to 0 IF Not Acceptable Check Noise Value and Sensitivity of the System C H If system is picking well Adjust until sensitive enough Your e Done If weak then increase until stable adjust H to approximately 1 2 of Noise Level if false alrarms adjust slightly Upward C Adjust from C6 to C1 until system is working well Than adj...

Страница 12: ...y shut down all the other systems including all the possible noise source such as lights electronic equipment and etc If it doesn t stop this system from false alarming please follow the above two methods in an inverse way A Increase Minimum Signal Adjustment by an increment of 20 The range is from 20 to 200 B Lower Gain Adjustment from 1 high to 0 low Secondly if all the other systems works prope...

Страница 13: ... Fig 1 2 Press password 961 Fig 2 3 Press confirm button Then enter the control parameters input state There usually are three steps in parameters input z Firstly select the parameter type like Gain Adjustment Sychron Adjustment or Noise Condition Display z Secondly input the numbers within a valid range z Thirdly press confirm button ...

Страница 14: ...t point of transmitting burst This is usually set for multiple systems working on a different power line with phase problem The range is 1 250 each stands for 34u seconds Fig 4 1 z Under this entry you can also see the different noise condition from the light segment display and number indication at a different phase when the adjustment goes on It will help you to select a relative clean phase env...

Страница 15: ...to shut down the display 9DOXH XQFWLRQ HVFULSWLRQ HWHFWLRQ 3XUSRVH VKXW GRZQ WDJ RU QRLVH ZLQGRZ GLVSOD WDJ ZLQGRZ GLVSOD IRU DQWHQQD DQG FKDQQHOV WDJ ZLQGRZ GLVSOD IRU DQWHQQD DQG FKDQQHOV DYHUDJH QRLVH ZLQGRZ GLVSOD IRU DQWHQQD DQG FKDQQHOV DYHUDJH QRLVH ZLQGRZ GLVSOD IRU DQWHQQD DQG FKDQQHOV LQVWDQWDQHRXV QRLVH ZLQGRZ GLVSOD IRU DQWHQQD DQG FKDQQHOV LQVWDQWDQHRXV QRLVH ZLQGRZ GLVSOD IRU DQWHQQD...

Страница 16: ...d false alarming caused by uncontrollable environment noise 2 Configuration Loading Mode Setting range 0 1 Also under this setting entry there are three modes of system configuration loading z Inputting 1 will set the system to power on self detection mode in which system will automatically configure all the parameters z By inputting 0 system will load the default parameters from Flash ROM See the...

Страница 17: ... parameters to flash ROM so when power shut down the parameters will not be lost After press this button you should press confirm button to confirm saving Notice But any adjustment of H as 0 default parameters loading mode or 1 self detection mode will deactivate the application of the saved parameters Fig 9 ...

Страница 18: ...uire opening the equipment cover or enclosure are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so Symbols and Their Meanings The exclamation point within an equilateral triangle alerts the user to the presence of important operating and maintenance...

Страница 19: ...Disconnect AC power before installing any options The attachment plug receptacles in the vicinity of the equipment are all to be of a grounding type and the equipment grounding conductors serving these are to be connected to earth ground at the service equipment This equipment is grounded through the grounding conductor of the power cord To avoid electrical shock connect the power cord to the equi...

Страница 20: ...le that caused the fuse to blow before applying power Verify that all power supply lights are off before removing the power supply or servicing equipment Use only specified replacement parts Leave the base of the system clear for air exhaust cooling and to allow room for cabling Slots and openings in the system are provided for ventilation Do not block them To prevent damage to this equipment read...

Страница 21: ...s are color coded white neutral black line and green or green yellow ground Operation of this equipment at voltages exceeding 130 VAC will require power supply cords which comply with NEMA configurations International Power Supply Cord This equipment is supplied with an external power line at one end and a molded receptacle terminal block at the other end Conductors are CEE color coded light blue ...

Страница 22: ...set Compare the manuals against the Inventory sheet and make a note of any discrepancies Carefully remove the contents of container and place on a flat level surface Compare the contents with the Part List to ensure that there no missing items Make a note of any discrepancies Equipment Inspection Inspect all equipment for damage Items to specifically check and damage to look for are listed below A...

Страница 23: ...are no discrepancies and either no damage or GVG advised correction action is made continue with this manual Facility Checklist The following checklist is a synopsis of information found in the appropriate Installation Planning Guide The Planning Guide should be referred to for detailed site preparation information Ensure that there are sufficient AC power outlets of the required 3 prong grounded ...