Reverse Battery Protection
This feature prevents permanent damage to the converter from an incorrect
battery connection.
Automatic Cooling Fan
The fan is variable speed and current controlled.
Electronic Current Limiting
Automatically shuts down power during overload or short-circuit conditions.
Automatically returns to normal operation after conditions are corrected.
DC Fuses (12 Volts)
- Eighteen 12 Volt circuits; circuits 1 thru 15 rated at 20 amps max. and
circuits 16 thru 18 rated at 30 amps max. Circuits 16 thru 18
recommended for slideout use.
- Reverse battery protection fuses; replace with
ATC “Littelfuse ” Type 257 fuse or equivalent.
AC Circuit Breakers (120/240 Volts) UL Listed
®
General Consumer Information
This product should be installed by an experienced technician.
CAUTION
and care must be taken when servicing this equipment.
To prevent severe shock or electrocution consult your servicing dealer.
No serviceable parts.
CAUTION
!
!
WARNING
!
!
CAUTION
!
!
This unit employs components that tend to produce arcs or sparks.
To prevent fire or explosion, do not install in compartments
containing batteries or flammable materials
For continued protection against risk of fire, or electric shock
replace only with same type and ratings of fuse
.
(LP gas)
.
®
Check on a monthly basis the fluid level in any battery connected to RV
charging system.
This product is not ignition protected and should not be installed in an
LP compartment.
CAUTION
!
!
Installation and Servicing of the WFCO WF-9900 Series Power Center
Manufacturer:
EATON
ITE/Siemens
Square D
Murray
Model/Cat. No./Type:
Type BR
Type QP or QT
Type HOM
Type MH or MP
Manufacturer:
ITE/Siemens
Square D
Murray
Model/Cat. No./Type:
Type BRD
Type QP or QT
Type HOMT
Type MHT or MPT
Breaker Filler Plates:
Manufacturer:
WFCO
Model/Cat. No./Type
FP-01 or FP-01B
Max. Main Circuit Breaker Size: 50 Amp two pole or
Equivalent.
Note:
Use only 2-pole circuit breakers for Main Circuit
breaker.
Max. Branch Circuit Breaker Size: 20 Amp or 20 Amp Two Pole
A replacement or additional circuit breaker shall be of the same
manufacturer, type designation, and equal or greater interrupting
rating.
For Breaker tightening torque ratings, refer to Circuit breaker.
For
Neutral and Ground terminal bar torque and wire size refer to the
label on the door
.
assembly
EATON