WF-10T
Case Former
Controls
5-34
5.7.1 Case Orientation Change-over Procedure
The default case orientation, or ‘handing’, for WF-10T case formers is
configured with right-handed cases. Machine operators requiring left-
handed case orientation can change the machine’s case orientation
by following the instructions below. For someone familiar with the
process, performing a case size change-over should take
approximately half an hour. See the following page for diagram of
pertinent parts.
1) In
the
‘SETUP’
screen, toggle the
‘CASE ORIENTATION’
toggle switch
ON
or
OFF
. In the machine’s default
orientation, the switch will be ON (illuminated green) and
display the text
‘LEFT HAND
ACTIVE’.
The toggle switch
will turn gray and display the text
‘RIGHT HAND
ACTIVE’
only when the machine operator has pressed the switch.
Note that handing changes require the machine operator to
enter a password, which will have been provided at the time
of purchase.
2)
Follow the shutdown procedure outlined in Section 6.5:
‘Shutdown’
. If required, lock out pneumatic and electrical
disconnects as required by local regulations.
3)
Open a guard door and enter the machine’s restrictive envelope. Locate the carriage
assembly. Using a 5/32” Allen key, remove the jawplate mounting screws that secure the
jawplates to the jaw mount plates. Detach jawplates from machine.
4)
Remove the pivot link mounting screws that secure the pivot links to the carriage
assembly. Detach pivot links from machine and replace with provided replacement pivot
links for right-hand jawplate orientation. Secure replacement pivot links with provided
screws.
5)
Remove the 4 screws that secure the major jawplate to the major jawplate extension
mount and that secure the major jawplate extension to the extension mount. Reorient
the jawplate extension and jawplate extension mount on the opposing side, ensuring that
the extension mount is mounted towards the discharge end of the machine. Replace
screws.
6)
Reattach the jawplates to the jaw mount plates using the screws provided. Ensure that
you reverse the position of the jawplates so that they are mounted opposite to the original
configuration. The major jawplate should be mounted towards the discharge end of the
machine.
7)
Detach Magazine Plate 7 (Item # 22 on drawing 610-0002) from the Magazine Taper
Plate and reattach it on the opposite side of the centerline in the bolt holes provided.
8)
It may be necessary to recalibrate the jawplate cylinder flow controls when conducting a
handing change-over. Call Wexxar Service Department for more detailed information.
9)
Close the guard door and restart the machine according to the procedure outlined in
Section 6.2:
‘Start-up’
. The case orientation changeover is now complete.
.
Figure 5-36: 'Case
Orientation’ Toggle
Switch
Содержание WF-10T
Страница 2: ...WF 10T Case Former ...
Страница 118: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 106 ...
Страница 119: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 107 ...
Страница 120: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 108 ...
Страница 121: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 109 ...
Страница 122: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 110 ...
Страница 123: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 111 ...
Страница 125: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 113 ...
Страница 126: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 114 ...
Страница 127: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 115 ...
Страница 128: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 116 ...
Страница 129: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 117 ...