Please read and save these instructions. Read through this owner’s manual carefully before using product. Protect yourself and others by observing all safety information, warnings, and cautions. Failure to
comply with instructions could result in personal injury and/or damage to product or property. Please retain instructions for future reference.
RAD103
Printed in China
7/08
1
Operating Instructions and Parts Manual
2LTC6
THERMOCOUPLE THERMOMETER
boo
Description
The actual range depends on the probe
specification. PROBES ARE NOT INCLUDED WITH THE UNIT.
ELECTRO-STATIC DISCHARGE. The
measurement range is for the thermometer only. Choose appropriate
probe for the application to avoid permanent damage. Target to be
measured should not exceed the temperature range of the probe.
To avoid electric shock and thermometer
damage, DO NOT MEASURE LIVE CIRCUITS, if voltage exceeds 24V
AC RMS or 60V DC with this instrument.
“Thermal Shock” may be caused by large or
abrupt ambient temperature changes. Allow 30 minutes for the unit
to stabilize before use when exposed to “Thermal Shock”.
Do not leave the unit on or near
objects of high temperature.
KEEP OUT OF REACH OF
CHILDREN.
This Westward® Thermocouple Thermometer is handheld and compact used for temperature sensor
measurements using K type thermocouple inputs. It adapts with various probes (not included) to measure
temperature ratings for various applications applied. Instrument accuracy is +/- 1% of the reading.
Unpacking
After unpacking unit, inspect carefully for any damage that may have occurred during transit. Check for
loose, missing, or damaged parts. Shipping damage claim must be filed with carrier.
Specifications and Dimensions
Features & Benefits
▪
Digital
▪
15 Second Auto Power Off
▪
°C/°F Switch
▪
Large Display
▪
Handheld
▪
Precise
▪
K-Thermocouple Type Socket
▪
Ease of Use
▪
IP65 Splash Proof
▪
Easy Storage
▪
Includes Magnet
Warranty
Probe Measurement
Range
Operating
Temp Range
Resolution
Accuracy
Battery Life
Battery Life
-83.2~1999°F
-64~1400°C
32~122°F
0~50°C
0.1°F
0.1°C
(Tamb = 25°C):
+/- 1% of the
reading or 1°C
(1.8°F);
whichever is
1 (CR2032)
100hrs
continuous use
LIMITED ONE-YEAR WARRANTY
Should this product fail to perform satisfactorily due to a defect or poor workmanship within ONE YEAR from the date of purchase,
o the place of purchase and it will be replaced free of charge. Incidental or consequential damages are excluded from this
warranty.
Operation
Before using this tool read directions thoroughly.
To switch thermometer on, press “ON/HOLD” and hold for approximately one second.
LCD displays: Temperate Reading, Battery Status, Hold
Display for current measured values
Minus sign (negative measured values)
Measuring Temperature
1 Select the appropriate K-Type socket probe then plug it into the unit input
2 Select the required unit of measurement °C/°F
3 °C/°F can be changed only when “HOLD” is shown
4 Position the tip of the thermocouple where you wish to measure the temperature and
press “ON/HOLD” key. Wait until the temperature has stabilized and then read the value from
the display. The current temperature is displayed for 4 minutes.
Note:
The actual range depends on the probe spec.
Note:
The last measured value will be stored and the thermometer will deactivate itself
Automatically after 15 seconds to save the battery power.
Warranty
LIMITED ONE-YEAR WARRANTY
Should this product fail to perform satisfactorily due to a defect or poor workmanship within ONE YEAR from the date of purchase,
return it to the place of purchase and it will be replaced free of charge. Incidental or consequential damages are excluded from this
warranty.