Important:
Before first use make sure to insert the supplied 9 V
battery as described in chapter “Changing the Battery”.
Connecting the Measuring Cables
Important!
The maximum allowable input voltage is 600 V (CAT
III
) resp. 1000 V (CAT
II
) and may not be exceeded.
The measuring cables provided are capable of taking measure-
ments up to a maximum of 1000 V AC/DC, max 10 Ampere. The
measurement of high voltages should always be performed with
great care and only when a person trained in first aid is present.
If the measuring range is exceeded, on the display the
overload symbol “1“ will appear. For this case, select a
higher measuring range.
Measuring Category Explanation (CAT
I
, CAT
II
, CAT
III
)
The measuring category
I
is intended for taking measurements
on circuitry not directly connected to the power mains.
The measuring category
II
is intended for taking measurements
on low-voltage circuitry. Examples for this are household
appliances, mobile electric devices or similar equipment.
The measuring category
III
is intended for taking measurements
on house installations. Examples are distribution boxes, circuit
breakers, wiring, terminal strips, connectors, switches, and wall
sockets of the fixed installations, but also for measurements on
industrial devices and equipment such as permanently installed
motors.
Using the Stand
The unit is fitted with a stand (14) on the back, with which it can
be propped up on a table or similar. To use the stand, just grasp
the lower end of the flap and pull it outwards.