LEONARDO PRO X
User manual
EN
15
2.2.6. Connecting WRM Charge Regulators
–
DC Configuration ONLY
Pic.17 - WRM c
harge
regulators connection
Connect the cables to the RS485 terminal block of the regulator as in
Pic.17
(connect only A and B) for all installed
regulators. A maximum of 24 devices can be installed.
Crimp the 4 pole plug/body 6 as in
Pic.17
and insert it in the WBUS port
.
Set the address ID2 in the first regulator, ID3 in the second regulator and so on.
For WRM60 X SL follow the connections in
A5
using the supplied cable.
Always refer to the WRM30+, WRM60 X controllers manuals for power connections and address settings.
2.2.7. LEONARDO PRO X SL Installation
It is possible to expand your system by installing LEONARDO PRO X SL.
Leonardo PRO X SL
is used either to expand a single-phase system by
combining it with a Leonardo PRO X, or on three-phase systems with powers
up to 32 kW.
Installation of
Leonardo PRO X SL
is performed by referring to the diagrams
in
Pic.18, Pic.19
and
Pic.20
.