![Western Digital Ultrastar DC HC310 Скачать руководство пользователя страница 318](http://html1.mh-extra.com/html/western-digital/ultrastar-dc-hc310/ultrastar-dc-hc310_specifications_961649318.webp)
304
Western Digital Hard Disk Drive OEM Specification
11.72
Write Stream Ext (3Bh)
Com m and Block Output Registers
Com m and Block Input Registers
Register
7
6
5
4
3
2
1
0
Register
7
6
5
4
3
2
1
0
Data Low
-
-
-
-
-
-
-
-
Data Low
-
-
-
-
-
-
-
-
Data High
-
-
-
-
-
-
-
-
Data High
-
-
-
-
-
-
-
-
Feature
Current
V
V
V
V
-
V
V
V
Error
...See Below ...
Previous
V
V
V
V
V
V
V
V
Sector Count
Current
V
V
V
V
V
V
V
V
Sector Count
HOB=0
-
-
-
-
-
-
-
-
Previous
V
V
V
V
V
V
V
V
HOB=1
-
-
-
-
-
-
-
-
Sector Number
Current
V
V
V
V
V
V
V
V
Sector Number
HOB=0
V
V
V
V
V
V
V
V
Previous
V
V
V
V
V
V
V
V
HOB=1
V
V
V
V
V
V
V
V
Cylinder Low
Current
V
V
V
V
V
V
V
V
Cylinder Low
HOB=0
V
V
V
V
V
V
V
V
Previous
V
V
V
V
V
V
V
V
HOB=1
V
V
V
V
V
V
V
V
Cylinder High
Current
V
V
V
V
V
V
V
V
Cylinder High
HOB=0
V
V
V
V
V
V
V
V
Previous
V
V
V
V
V
V
V
V
HOB=1
V
V
V
V
V
V
V
V
Device/Head
1
1
1
D
-
-
-
-
Device/Head
-
-
-
-
-
-
-
-
Command
0
0
1
1
1
0
1
1
Status
...See Below ...
Error Register
Status Register
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
CRC
UNC
0
IDN
0
ABT
T0N
CCTO
BSY
RDY
SE
DWE
DRQ
COR
IDX
ERR
V
0
0
V
0
V
0
V
0
V
V
0
-
0
-
V
Table 263 Write Stream Ext Command (3Bh)
This command writes from 1 to 65536 sectors as specified in the Sector Count register. A sector count of 0
requests 65536 sectors.
If the Write Continuous bit is set to one, the device shall not stop execution of the command due to errors. If the
WC bit is set to one and errors occur in the transfer or writing of the data, the device shall continue to transfer the
amount of data requested and then provide ending status with the BSY bit cleared to zero, the SE bit set to one, the
ERR bit cleared to zero, and the type of error, IDNF, or ABRT, reported in the error log. If the WC bit is set to one
and the Command Completion Time Limit expires, the device shall stop execution of the command and provide
ending status with BSY bit cleared to zero, the SE bit set to one, the ERR bit cleared to zero, and report the fact t hat
the Command Completion Time Limit expired by setting the CCTO bit in the error log to one, In all cases, the
device shall attempt to transfer the amount of data requested within the Command Completion Time Limit event if
some data transferred is in error.