Installation Guide
1. Overview
1.4 Ultrastar Data60 Rack Requirements
Specification
Value
Inrush Current Maximum (per
PSU)
AC line inrush current shall not exceed 40A peak for up to
one-quarter of the AC cycle, after which, the input current
should be no more than the specified maximum input current.
Caution:
The Ultrastar Data60 can only be plugged into highline. If the unit is plugged into
lowline, the PSU will report a "Critical" state when status pages are queried using SES. In this
case, the enclosure will power up, but the drives will not. The enclosure will remain in low-
power mode.
Table 4:
Mechanical Specifications
Specification
Non-Operational
Operational
Shock
10G, 0 - peak,11ms half sine;
3 positive and 3 negative
pulses in each axis Shock
5G, 0 - peak, 11ms half sine; 3 positive
and 3 negative pulses in each axis-
minimum 6 seconds between shocks
to allow for write/read recovery
Vibration
0.75G, 0 - peak swept sine;
5 -500Hz; 1 complete sweep
@ 1/2 octave per minute
0.10G,0 - peak swept sine; 5
-500Hz; 1 complete sweep
@ 1/2octave per minute
Weight
79.4 kg. / 175 lbs.
Dimensions
447mm x 890mm x 175mm / 17.67in. x 35.04in. x 6.89in.
Length without CMA
712 mm / 28.03in.
Required Rack Width
450mm (17.72in.) with 465mm (18.31in.) ± 1.5mm
nominal hole spacing. See EIA-310 Rack Standard
Required Rack Depth
900mm (35.43in.) usable rack space, frame to frame
Rack Units (U)
4U
Vertical Rack Rail
Spacing
24 in. - 32 in.
Table 5:
Performance Specifications
Specification
Value
Number of Drive Slots
60
Data Transfer Rates
12Gbps SAS / 6Gbps SATA
Max Raw Data Storage Capacity
840 TB using 14TB Ultrastar® HC530 drives
SAS Ports
12
x
Mini-SAS HD ( 6 per IOM)
2
x
10/100/1G Ethernet
1.4
Ultrastar Data60 Rack Requirements
5