ActiveScale™ P100 Support Guide
55
Warning:
There is no lock or warning indication that the Storage Node is about
to come free from the rack. Use extreme caution.
6. Grasp the Storage Node and pull it out of the rack using even pressure.
7. Record the serial number for return purposes. The serial number and part number are located on a
pull-out tab located to the right of the SSD drive.
3.3.4.2 Installing a Storage Node
To install the replacement Storage Node:
1. Slide the Storage Node into the rack until it stops.
2. Tighten the thumb screws on the front of the Storage Node.
3. Replace the 2.5 inch drives. For more information, refer to
4. Replace the 3.5 inch drives. For more information, refer to
5. Reconnect all of the cables in the original configuration. For more information, refer to
6. Power on the Storage Node using the power button on the front panel.
7. If Western Digital Corporation support is not onsite, contact customer support for the final post-
replacement procedures for bringing the Storage Node online.
3.4 Mounting kit replacement instructions
ActiveScale systems can use different rail kits for each component. Use the following table to determine
which sections are relevant for your mounting kits.
Component
Mounting kit type
Relevant topics
System Node
1U
•
Replacing System Node 1U
mounting kits
3U
•
System Interconnect
3U
•
Storage Node
1U
•
Replacing Storage Node 1U
mounting kits
3U
•
Содержание ActiveScale P100
Страница 103: ...ActiveScale P100 Support Guide 101...
Страница 104: ...ActiveScale P100 Support Guide 102...
Страница 120: ...ActiveScale P100 Support Guide 118...
Страница 124: ...ActiveScale P100 Support Guide 122...
Страница 131: ...ActiveScale P100 Support Guide 129...
Страница 132: ...ActiveScale P100 Support Guide 130...