background image

User Guide
6641-22511

REV. E

©W

estermo T

eleindustri AB

www.westermo.com

FRNT

RSTP

DC

ON

X8

X12

X7

X6

X10

X11

X5

X9

X1

USB

X2

X3

X4

24-110V

DC

1000BASE-T

CON

M

1

2

 T

or

que 0.6±0,1

 Nm / 0,45±0,1

 lbft      

FRNT

RSTP

DC

ON

X8

X12

X7

X6

X10

X11

X5

X9

X1

USB

X2

X3

X4

24-110V

DC

1000BASE-T

CON

M12 T

or

que 0.6±0,1

 Nm / 0,45±0,1

 lbft      

FRNT

RSTP

DC

ON

X8

X12

X7

X6

X10

X11

X5

X9

X1

USB

X2

X3

X4

24-110V

DC

1000BASE-T

CON

M

1

2

 T

or

que 0.6±0,1

 Nm / 0,45±0,1

 lbft      

Viper 12A Series

12 port Ethernet M12 switches

Содержание Viper 12A Series

Страница 1: ... 1000BASE T CON M12 Torque 0 6 0 1 Nm 0 45 0 1 lbft FRNT RSTP DC ON X8 X12 X7 X6 X10 X11 X5 X9 X1 USB X2 X3 X4 24 110V DC 1000BASE T CON M12 Torque 0 6 0 1 Nm 0 45 0 1 lbft FRNT RSTP DC ON X8 X12 X7 X6 X10 X11 X5 X9 X1 USB X2 X3 X4 24 110V DC 1000BASE T CON M12 Torque 0 6 0 1 Nm 0 45 0 1 lbft Viper 12A Series 12 port Ethernet M12 switches ...

Страница 2: ...nce Information 7 2 6 1 Agency Approvals and Standards Compliance 7 2 6 2 FCC Part 15 105 Notice 7 2 6 3 Declaration of Conformity 8 3 Product Description 9 3 1 Product Description 9 3 2 Available Models 9 3 3 Hardware Overview 10 3 4 Connector Pinout 11 3 5 LED Indicators 13 3 6 Dimensions 13 4 Installation 15 4 1 Wall Mounting 15 4 2 Connection of Cables 15 4 3 Cooling 16 4 4 Removal of Product ...

Страница 3: ...es information on safety and regulations a product description installation instructions and technical specifications 1 3 Software Tools Related software tools are available in the folder Software tools under Technical support at www westermo com 1 4 License and Copyright for Included Free Libre Open Source Software This product includes software developed by third parties including Free Libre Ope...

Страница 4: ...hazardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Minor damage to the product NOTICE Provides information in order to avoid misuse of the product confusion or misunderstanding No personal injury Minor damage to the product NOTE Used for highlighting general but important information No persona...

Страница 5: ...ed temperature range e g by avoiding obstruction of the airflow around the unit Also see EN 45545 2 Mounting Notes 16 chapter WARNING PREVENT ACCESS TO HAZARDOUS VOLTAGE Before mounting using or removing this unit Prevent access to hazardous voltage by disconnecting the unit from all power supply WARNING HAZARDOUS VOLTAGE Do not open the connected unit Hazardous voltage may occur within this unit ...

Страница 6: ...nit Do not expose the unit to any kind of liquid water beverages paint etc unless all connectors are connected or fitted with protective caps delivered with the unit tightened to the specified torque Connected cables must have the appropriate ingress protection code Do not use or store the unit in dusty or dirty areas unless all connectors and the ventilation membrane are sufficiently protected Do...

Страница 7: ...EN 60068 2 27 20 g 11 ms and 100 g 6 ms Insulation Coordination and test EN 50124 1 Railway applications Insulation coordination EN 50155 IEC 60571 Railway applications Electronic equipment used on rolling stock Fire protection EN 45545 2 Fire protection on railway vehicles NFPA130 Fire protection for fixed guideway transit and passenger rail system Table 2 Agency approvals and standards complianc...

Страница 8: ...estriction of the use of certain hazardous substances in electrical and electronic equipment RoHS References of standards applied for this EU declaration of conformity No Title Issue EN 50121 3 2 Railway applications Electromagnetic compatibility Rolling stock Apparatus 2015 EN 50121 4 Railway applications Electromagnetic compatibility Emission and immunity of the signaling and telecommunications ...

Страница 9: ...imised design results in an extremely compact package in combination with very high MTBF for easy integration and low lifecycle cost Thorough type testing at independent ISO IEC 17025 and ILAC MRA certified labs accredited to a wide range of standards show that the Viper series fulfilles EN 50155 and other requirements The state of the art Westermo production facility ensures the quality of each i...

Страница 10: ...0 V DC M12 Torque 0 6 0 1 Nm 0 45 0 1 lbft 1000BASE T USB 1 2 3 4 5 7 6 No Description No Description 1 LED indicator 2 100 Mbps port 3 Gbps port 4 DC port 5 Console port 6 Protective earth connection 7 USB port Figure 1 Location of interface ports and LED indicators 10 Viper 12A Series ...

Страница 11: ...positive inputs are DC1 and DC2 The negative input for both supplies is COM Table 3 Power connector Pin no Signal Illustration 1 NCa 2 TX 3 RX 4 NCa 5 GND aNo Connect Do not connect Table 4 Console connector Pin no Signal Illustration 1 DN 2 VBUS 3 NCa 4 DC 5 GND aNo Connect Do not connect Table 5 USB connector Viper 12A Series 11 ...

Страница 12: ... MDI MDI X and auto MDI MDI X modes are supported The table shows signals in MDI mode Table 6 100 Mbps Ethernet connector Pin no Signal Illustration 1 DA 1 2 3 4 5 6 7 8 2 DA 3 DB 4 DB 5 DD 6 DD 7 DC 8 DC Table 7 Gbps connector 12 Viper 12A Series ...

Страница 13: ...es pending cable factory reset RSTP OFF RSTP disabled GREEN RSTP enabled BLINK Unit selected as RSTP STP root switch FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT error BLINK Unit configured as FRNT focal point DC OFF Unit has no power GREEN Power OK on DC1 and DC2 RED Power failure on DC1 or DC2 X1 to X12 OFF No link GREEN Link established GREEN FLASH Data traffic indication YELLOW Port alarm or ...

Страница 14: ...56 0 3 164 0 5 100 175 36 65 7 4 0 5 Grounding point screw M5x10 7 2 0 2 0 5 Figure 2 Dimensional drawing 14 Viper 12A Series ...

Страница 15: ...ue 0 6 0 1 Nm 0 45 0 1 lbft 1000BASE T USB Figure 3 Wall mounting 4 2 Connection of Cables Recommended tightening torque for the M12 connectors is 0 6 Nm When connecting the power cable ensure that the pins are connected correctly before tightening the power cable to the unit NOTICE UNUSED CONNECTORS Unused connectors must be covered by a protective cap delivered with the unit tightened to the spe...

Страница 16: ... replacement 10 minutes CAUTION HOT SURFACE Be aware of that the surface of this unit may become hot When this unit is operated at high temperatures the external surface of the equipment may exceed Touch Temperature Limit according to EN IEC UL 60950 1 4 5 EN 45545 2 Mounting Notes Two units can be mounted together and as a single interior non listed group in the sense of EN 45545 2 definitions Fo...

Страница 17: ...t 24 VDC 32 mA s at 110 VDC Startup currenta Max 840 mA at 16 8 VDC Polarity Reverse polarity protected Redundant power input Yes Isolation to 2250 VDC to all other ports Connector 4 pin male M12 A coded recommended Westermo cables 3146 1106 for 1 5 m 3146 1107 for 5 m Cable size M12 recommended cable area 0 5 mm minimum 0 25 mm Cable dimensions depend on choice of M12 connector aExternal supply c...

Страница 18: ...iguration time Typically below 20 ms a100 Mbps ports are X1 X12 on Viper x12A X1 X3 X5 X7 X9 X11 on Viper x12A T3G X1 X5 X7 X9 X11 on Viper x12A T5G b750 VDC after damp heat according to EN 50155 Gbps portsa Electrical specification IEEE std 802 3 Data rate 10 Mbps 100 Mbps 1000 Mbps manual or auto Circuit type TNV 1 Transmission range Up to 150 m with CAT5e cable or better Isolation to 2250 VDC t...

Страница 19: ...s Connector 5 pin female M12 A coded recommended Westermo USB plug 3641 0190 Console port Electrical specification RS 232 Data rate 115 2 kbit s Data format 8 data bits no parity 1 stop bit no flow control Circuit type SELV Isolation to Ethernet and DC ports 2250 VDC No isolation to USB or chassis Connector 5 pin female M12 B coded recommended Westermo cables 1211 2215 serial port or 1211 4073 USB...

Страница 20: ... EN 61000 4 3 Enclosure 20 V m at 80 MHz to 2 GHz 10 V m at 2 6 GHz 1 kHz sine 80 AM Conducted RF immunity EN 61000 4 6 Power ports 10 V 80 AM 1 kHz 0 15 80 MHz Ethernet ports Earth port Radiated RF emission CISPR 16 2 3 Enclosure EN 61000 6 4 30 6000 MHz ANSI C63 4 FCC Part 15 EN 61000 6 4 30 6500 MHz Conducted RF emission CISPR 16 2 1 Power port EN 61000 6 4 Ethernet ports EN 61000 6 3 Dialectri...

Страница 21: ...5 sweeps IEC 60068 2 64 random Non operational long life simulation 11 44 m s rms 5 150 Hz 5 hours 2 3 m s rms 5 2000 Hz 5 hours Shock IEC 60068 2 27 Operational 10 g 30 ms half sine 20 g 11 ms saw tooth 100 g 6 ms half sine Enclosure EN 60950 1 Zinc front Aluminium rear Fire enclosure Dimension WxHxD with connectors See Dimensions chapter for details Weight 1 4 kg Degree of protection EN 60529 En...

Страница 22: ...C throughout the user guide radiated RF immunity service life shock and operating temperature updated in chapter 5 2 Old chapters Getting started Configuration Reference documents and Cable factory reset are deleted Rev E 2017 09 2 1 Definition of personal injury at Caution level updated 2 6 1 Mechanical data updated 3 6 Dimensional drawing updated 5 1 Transmission range for 100 Mbps ports and Gbp...

Страница 23: ...23 Viper 12A Series ...

Страница 24: ...rmo fr Germany info westermo de www westermo de North America info westermo us www westermo us Singapore sales westermo com sg www westermo com sg Sweden info sverige westermo se www westermo se United Kingdom sales westermo co uk www westermo co uk Other Offices Sales Units Westermo Data Communications Westermo SE 640 40 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info wester...