background image

©

W

estermo 

Teleindustri 

AB

12 port Ethernet M12 switch  

with Power over Ethernet

www.westermo.com

User Guide

6641-22501

Viper-12A-PoE 

S E R I E S

FRNT

RSTP

DC

ON

X8

X12

X7

X6

X10

X11

X5

X9

X1

USB

X2

X3

X4

48-110 V

DC

1000BASE-T

M12 T

or

que 0.6±0,1 Nm / 0,45±0,1 lbft      

CON

PoE

FRNT

RSTP

DC

ON

X8

X12

RING

X7

X6

X10

X11

X5

X9

X1

USB

X2

X3

X4

48-110V

DC

M12 T

or

que 0.6±0,1 Nm / 0,45±0,1 lbft      

CON

PoE

FRNT

RSTP

DC

ON

X8

X12

X7

X6

X10

X11

X5

X9

X1

USB

X2

X3

X4

48-110V

DC

1000BASE-T

M12 T

or

que 0.6±0,1 Nm / 0,45±0,1 lbft      

CON

PoE

Содержание Viper-112A-P8-HV

Страница 1: ... ON X8 X12 X7 X6 X10 X11 X5 X9 X1 USB X2 X3 X4 48 110 V DC 1000BASE T M12 Torque 0 6 0 1 Nm 0 45 0 1 lbft CON PoE FRNT RSTP DC ON X8 X12 RING X7 X6 X10 X11 X5 X9 X1 USB X2 X3 X4 48 110V DC M12 Torque 0 6 0 1 Nm 0 45 0 1 lbft CON PoE FRNT RSTP DC ON X8 X12 X7 X6 X10 X11 X5 X9 X1 USB X2 X3 X4 48 110V DC 1000BASE T M12 Torque 0 6 0 1 Nm 0 45 0 1 lbft CON PoE ...

Страница 2: ...ntial or indirect damages howsoever caused More information about Westermo can be found at http www westermo com Software tools Related software tools are available in the folder software tools under technical support on the Westermo website License and copyright for included Free Libre Open Source Software This product includes software developed by third parties including Free Libre Open Source ...

Страница 3: ... be connected via an external fuse The fuse should be calculated in accordance with the rated current Before mounting using or removing this unit Prevent access to hazardous voltage by disconnecting the unit from all power supply WARNING Do not open connected unit Hazardous voltage may occur within this unit when connected to power supply Before powering up a protective earthing conductor must be ...

Страница 4: ...vered with the unit tightened to the specified torque Connected cables must have the appropriate ingress protection code Do not use or store the unit in dusty or dirty areas unless all connectors and the ventilation membrane are sufficiently protected Do not cover or bring mechanical force to the ventilation membrane on the back of the unit If the unit is not working properly contact the place of ...

Страница 5: ... Mechanical Shock and vibration EN 61373 category 1 class A EN 60068 2 27 10 g 30 ms Insulation Coordination and test EN 50124 1 Railway applications Insulation Coordination EN 50155 IEC 60571 Railway applications Electronic equipment used on rolling stock Fire protection EN 45545 2 Fire protection on railway vehicles FCC Part 15 105 Notice This equipment has been tested and found to comply with t...

Страница 6: ...tion of the use of certain hazardous substances in electrical and electronic equipment RoHS References of standards applied for this EU declaration of conformity No Title Issue EN 50121 3 2 Railway applications Electromagnetic compatibility Rolling stock Apparatus 2015 EN 61000 6 2 Electromagnetic compatibility Generic standards Immunity for industrial environments 2005 EN 61000 6 4 Electromagneti...

Страница 7: ...y EN 61000 4 3 Enclosure 20 V m 80 MHz 2 7 GHz 10 V m 2 7 6 GHz 1 kHz sine 80 AM Conducted RF immunity EN 61000 4 6 Power port 10 V 80 AM 1 kHz 0 15 80 MHz Ethernet ports 10 V 80 AM 1 kHz 0 15 80 MHz Earth port 10 V 80 AM 1 kHz 0 15 80 MHz Radiated RF emission CISPR 16 2 3 Enclosure Class A 80 6000 MHz ANSI C63 4 FCC Part 15 Class A 80 6500 MHz Conducted RF emission CISPR 16 2 1 Power port Class A...

Страница 8: ...hours 2 471 000 hours 1 MIL C217F2 GB 25 C 77 F 2 IEC 62380 Vibration IEC 60068 2 6 sine Operational 2g rms 5 500 Hz 5 sweeps IEC 60068 2 64 random Non operating long life simulation 11 44 m s rms 5 150 Hz 5 hours Shock IEC 60068 2 27 Operating 10 g 30 ms half sine 20 g 11 ms saw tooth Enclosure EN 60950 1 Zinc Fire enclosure Dimension W x H x D With connectors See Dimensions chapter for details W...

Страница 9: ... where the highest class is achieved in all aspects The state of the art Westermo production facility ensures the quality of each individual unit e g through temperature cycling burn in testing The WeOS operating system offers an extensive suite of IP networking features for resilient and flexible networks e g the FRNT ring protocol with very fast failover on 100 Mbps as well as Gbps ports The pow...

Страница 10: ... 48 V 65 mA s at 110 V Startup current Viper x12A TxG P8 LV 1 5 A at 16 8 VDC Viper x12A TxG P8 HV 750 mA at 33 6 VDC Polarity Reverse polarity protected Redundant power input No Isolation to 2250 VDC to all other ports Connection Viper x12A TxG P8 HV 4 pin male M12 A coded connector use e g Westermo cable 3146 1106 for 1 5 m 3146 1107 for 5 m Viper x12A TxG P8 LV 4 pin male M12 T coded connector ...

Страница 11: ...bps ports non PoE ports Electrical specification IEEE std 802 3 Data rate 10 Mbps 100 Mbps 1000 Mbps manual or auto Circuit type TNV 1 Transmission range Up to 100 m with CAT5e cable or better Isolation to 750 VDC to all other ports Connection 8 pin M12 X code Shielded cable Required FRNT reconfiguration time Typically below 20 ms Gbps non PoE ports are X4 X8 X12 on Viper x12A T3G P8 HV LV PoE por...

Страница 12: ... specification USB 2 0 host interface Data rate Up to 480 Mbps high speed mode Maximum supply current 500 mA Circuit type SELV Isolation to Ethernet and DC ports 2250 VDC No isolation to CON or chassis Connection 5 pin M12 female A code use Westermo USB plug 3641 0190 Console port Electrical specification RS 232 Data rate 115 2 kbit s Data format 8 data bits no parity 1 stop bit no flow control Ci...

Страница 13: ...al COM for negative terminal in order to distribute the current over two pins CON Pin number Signal No 1 NC No 2 TX No 3 RX No 4 NC No 5 GND USB Pin number Signal No 1 DN No 2 VBUS No 3 NC No 4 DP No 5 GND 100 Mbps Ethernet Pin number Signal No 1 TD No 2 RD No 3 TD No 4 RD MDI MDI X and auto MDI MDI X modes are supported The table shows signals in MDI mode Gbps Ethernet Pin number Signal 1 2 3 4 5...

Страница 14: ...he console port 2 Connect cable to your computer port 3 Use a terminal emulator and connect with correct speed and format 115200 8N1 to the assigned port For more information about the CLI see the WeOS Management Guide Connection to USB port The USB port can be used to copy configuration and log files to from the switch Connect the USB plug use Westermo USB plug 3641 0190 to the USB port For more ...

Страница 15: ...LINK during boot indicates pending cable factory reset RSTP OFF RSTP disabled GREEN RSTP enabled BLINK Unit elected as RSTP STP root switch FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT Error BLINK Unit configured as FRNT Focal Point DC OFF Unit has no power GREEN Power OK Input voltage 70 of minimum nominal voltage RED Power failure Input voltage 70 of minimum nominal voltage X1 to X12 OFF No Lin...

Страница 16: ...t is installed so that the ambient temperature is within the specified temperature range e g by avoiding obstruction of the airflow around the unit Hot surface Be aware of that the surface of this unit may became hot EN 45545 2 mounting notes Two Viper units can be mounted together and as a single interior non listed group in the sense of EN 45545 2 definitions For multiple units the spacing requi...

Страница 17: ...pter The Command Line Management Tool in the WeOS management guide Factory default IP address 192 168 2 200 and DHCP client Netmask 255 255 255 0 Gateway Disabled Note If you are not sure about the subnet consult your network administrator Configuration Configure the unit via web browser The unit can easily be configured via a web browser Open the link http 192 168 2 200 in your web browser and yo...

Страница 18: ...ndicates that the unit is now ready to be reset to factory default You now have the choice to go ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unplugging one of the Ethernet cables The ON LED will stop flashing This initiates the factory reset process and the unit will restart with fact...

Страница 19: ...19 6641 22501 Dimensions Measurements are stated in millimetres 164 100 7 56 82 110 177 3 7 82 110 177 3 ...

Страница 20: ... fr www westermo fr Germany info westermo de www westermo de North America info westermo us www westermo us Singapore sales westermo com sg www westermo com Sweden info sverige westermo se www westermo se United Kingdom sales westermo co uk www westermo co uk Other Offices Sales Units Westermo Data Communications Westermo SE 640 40 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail i...

Отзывы: