background image

©

W

estermo 

Teleindustri 

AB

12-port Ethernet M12 switch  

with Power over Ethernet

www.westermo.com

User Guide

6641-2252

Viper-12-PoE 

s e r i e s

DC

CON

FRNT

RSTP

ON

USB

X1

X5

X9

X6

X10

X7

X11

X8

X12

X4

PoE

X3

X2

Содержание Viper-112-P8

Страница 1: ...stermo Teleindustri AB 12 port Ethernet M12 switch with Power over Ethernet www westermo com User Guide 6641 2252 Viper 12 PoE s e r i e s DC CON FRNT RSTP ON USB X1 X5 X9 X6 X10 X7 X11 X8 X12 X4 PoE X3 X2 ...

Страница 2: ... warranties of any kind either express or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Under no circumstances shall Westermo be responsible for any...

Страница 3: ...nected to two different power sources When this unit is operated at an ambient temperature above 55 C 131 F the External Surface of Equipment may exceed Touch Temperature Limit according to EN IEC UL 60950 1 To reduce the risk of fire use only No 26 AWG or larger telecommunication line cord Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfill...

Страница 4: ...y applications Electronic equipment used on rolling stock FCC Part 15 105 Notice This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can r...

Страница 5: ...rmity No Title Issue EN 50121 3 2 Railway applications Electromagnetic compatibility Rolling stock Apparatus 2006 EN 50121 4 Railway applications Electromagnetic compatibility Emission and immunity of the signaling and telecommunications apparatus 2006 EN 55022 Information technology equipment Radio disturbance characteristics Limits and methods of measurement 2006 A1 2007 EN 55024 Information tec...

Страница 6: ...closure Class A FCC Part 15 Class A Conducted RF emission EN 55022 Power port Class A Ethernet ports Class B Dielectric strength EN 60950 1 Power port to all other ports 1 5 kV ACrms 50 Hz 1 min Fast Ethernet ports to all other ports not between PoE ports 1 5 kV ACrms 50 Hz 1 min Gigabit Ethernet ports to all other ports 500 V ACrms 50 Hz 1 min Environmental Temperatures Operating 40 to 70 C 40 to...

Страница 7: ...th stop filter and the unique Westermo protocol Fast Reconnect allows a video stream to reconfigure very fast Advanced functionality for VLANs with support for up to 64 virtual networks combined with real time properties is implemented in the switch in order to achieve determinism for real time critical applications Made easy and secure configuration You can safely access your switch from anywhere...

Страница 8: ...M12 connector External supply current capability for proper start up X1 X12 Ethernet ports Electrical specification IEEE std 802 3 2005 Edition Data rate 10 Mbit s 100 Mbit s manual or auto Duplex Full or half manual or auto Circuit type Viper x12 P8 X1 X12 TNV 1 Viper x12 T3G P8 X1 X3 X5 X7 X9 X11 TNV 1 X4 X8 X12 SELV Transmission range Up to 150 m with CAT5e cable or better non PoE ports only Is...

Страница 9: ... s 100 Mbit s 1000 Mbit s manual or auto Connection 8 pin M12 Transmission range Up to 100 m with CAT5e cable or better FRNT reconfiguration time Typically below 400 ms Note Full wirespeed 1000 Mbit s is not possible between port X4 and the other Gigabit ports due to hardware limitations USB USB port Electrical specification USB 2 0 host interface Data rate Up to 480 Mbit s high speed mode Maximum...

Страница 10: ... X3 X4 Ethernet connection TX X1 X12 for details see page 8 and 11 Power connection for details see page 8 and 11 LED indicators for details see page 13 Earth connection Ethernet connection TX X1 X12 for details see page 8 and 11 LED indicators for details see page 13 Power connection for details see page 8 and 11 RING Connect between these ports X8 X12 to get maximum performance in a ring topolog...

Страница 11: ... Pin number Signal 2 1 3 4 No 1 DC1 No 2 DC2 No 3 COM No 4 COM Viper 12 PoE supports redundant power connection The positive inputs are DC1 and DC2 the negative input for both supplies are COM USB Pin number Signal No 1 DN No 2 VBUS No 3 NC No 4 DP No 5 GND CON Pin number Signal No 1 NC No 2 TX No 3 RX No 4 NC No 5 GND Viper 112 T3G P8 Viper 212 T3G P8 X4 X8 X12 Pin number Signal 1 2 3 4 5 6 7 8 1...

Страница 12: ...h correct speed and format 115200 8N1 to the assigned port For more information about the CLI see the WeOS management guide Connection to USB port The USB port can be used to copy configuration and log files to from the switch The following steps needs to be taken 1 Connect the USB plug use Westermo USB plug 3641 0190 to the USB port 2 Access the switch CLI via console cable or SSH 3 Use the CLI c...

Страница 13: ...g Tool or when configur ing the unit via Web or CLI DC OFF Unit has no power GREEN Power OK on DC1 and DC1 RED Power failure on DC1 or DC2 FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT Error BLINK Unit configured as FRNT Focal Point RSTP OFF RSTP disabled GREEN RSTP enabled BLINK Unit elected as RSTP STP root switch X1 to X12 OFF No Link GREEN Link established GREEN FLASH Data traffic indication Y...

Страница 14: ...m the wall Time For Replacement 15 minutes Cooling This unit uses convection cooling Avoid obstructing the airflow around the unit Spacing is recommended for the use of unit in full operating temperature range and service life Wall mounting There are four 6 mm bore holes intended for mounting the unit The unit can be mount ed vertical or horizontal Use four M5 screws with 12 mm washer on a flat an...

Страница 15: ...lable in the chapter The Command Line Management Tool in the WeOS management guide Factory default IP address 192 168 2 200 Netmask 255 255 255 0 Gateway Disabled Note If you are not sure about the subnet consult your network administrator Configuration Configure the unit via web browser The unit can easily be configured via a web browser Open the link http 192 168 2 200 in your web browser and yo...

Страница 16: ...ve the choice to go ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet cables The ON LED will stop flashing This initiates the factory reset process the unit will restart with factory default settings When the switch has booted up the ON LED will show a green light an...

Страница 17: ...24 23 3 48 48 8 72 73 5 99 3 1 5 110 7 1 5 Material Remark Designation Dimension Description Quantity Pos No 1 1 Scale Status Designer Drawing No PaPu Approved 6001 0002 U 01 Sheet 1 1 Denomination Viper 12 P8 series Dimensional Drawing 2010 Westermo Teleindutri AB All rights reserved Approved Date 130225 Description Designer Rev Date Approved ToDu PaPu 01 Created 130225 ToDu ...

Страница 18: ......

Страница 19: ......

Страница 20: ...rmo de www westermo de Austria Westermo Data Communications Tel 43 0 72030 3920 Fax 43 0 2235 86131 info westermo at www westermo at France Westermo Data Communications Bat A 9 Chemin de Chilly FR 91160 Champlan Tel 33 1 69 10 21 00 Fax 33 1 69 10 21 01 infos westermo fr www westermo fr North America Westermo Data Communications 939 N Plum Grove Road Suite F IL 60173 Schaumburg USA Tel 1 847 619 6...

Отзывы: