background image

Viper-008

Unmanaged 8-port Ethernet Switch

www.westermo.com

Содержание Viper-008

Страница 1: ...Viper 008 Unmanaged 8 port Ethernet Switch www westermo com ...

Страница 2: ...2 6641 2211 ...

Страница 3: ...ressed or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose Westermo reserves the right to revise this document or withdraw it at any time without prior notice Under no circumstances shall Westermo be responsible for any loss of data or income or any special incidental and consequential or indirect damages howsoever caused More info...

Страница 4: ...a potentially hazardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides information in order to avoid misuse of the product confusion or misunderstanding No personal injury Minor damage to the product NOTE Used for highlighting general but important infor...

Страница 5: ...stallation ensure a protective earthing conductor is first connected to the protective earthing terminal only valid for metallic housings Westermo recommends a cross sectional area of at least 4 mm2 Upon removal of the product ensure that the protective earthing conductor is disconnected last HAZARDOUS VOLTAGE Do not open an energized product Hazardous voltage may occur when connected to a power s...

Страница 6: ...duct s relevant electrical safety standard ELECTROSTATIC DISCHARGE ESD Prevent electrostatic discharge damages to internal electronic parts by discharging your body to a grounding point e g use a wrist strap REDUCE THE RISK OF FIRE To reduce the risk of fire use only telecommunication line cords with a cable diameter of AWG 26 or larger Regarding power cable dimensions see Interface Specifications...

Страница 7: ... used in a manner not according to specification the protection provided by the equipment may be impaired If the product is not working properly contact the place of purchase nearest Westermo distributor office or Westermo technical support Product Disposal This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it It needs to be handed over to an appl...

Страница 8: ...5545 2 Fire protection on railway vehicles Safety EN IEC UL 62368 1 Safety Requirements for audio video information and communication technology equipment Compliance Information EN IEC UL 62368 1 Notice This product has been tested and found compliant to EN IEC UL 62368 1 Safety for Communication Technology In accordance with the definitions of the standard this product shall be handled by ordinar...

Страница 9: ...uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on ...

Страница 10: ...ltage variation Radiated emission CISPR 16 2 3 ANSI C63 4 FCC part 15 Enclosure Class B 30 6000 MHz Conducted emission CISPR 16 2 1 DC power port Ethernet ports Class B Dielectric strength EN 50155 Ethernet ports to other isolated ports 500 VAC 1 min Power Fault port to other isolated ports 1500 VAC 1 min Temperature EN 60068 2 1 EN 60068 2 2 Operating 40 to 70ºC Storage Transport 40 to 85ºC Humid...

Страница 11: ... 100 m s2 Transverse 100 m s2 Longitudinal 100 m s2 11 ms 3 x 6 shocks Enclosure UL 94 Nickel coated zinc Flammability class V 1 Dimension W x H x D 175 x 100 x 53 4 mm Weight 0 9 kg Degree of protection IEC 529 Enclosure IP 65 when all ports are protected connected else IP 40 Cooling Convection Mounting DIN Rail or wall mounted ...

Страница 12: ... 100 ms Rated current 110 mA 24 VDC 33 mA 110 VDC Rated frequency DC Inrush current I2t Max 0 02 A2s 24 110 VDC Polarity Reverse polarity protected Startup current 300 mA 16 8 VDC Redundant power input No Isolation to Connections X1 X8 and to ground 1500 VAC Fault relay belongs to the same isolation group as the power supply lines fault relay signals are also contained within PWR Connection 4 pin ...

Страница 13: ... on the power input Description of how connection to the fault contact could be done is shown below The relay is closed when the unit is OK and open at failure The relay is of semiconductor type no moving parts It is specified for max current 250 mA continuous 500 mA peak 10 ms operational voltage up to 110 V protected by a 150 VDC varistor ON resistance less than 10 Ohm and leakage current max 1 ...

Страница 14: ... VAC Galvanic connection to None except for shielded contact to housing Connection 4 pole M12 female with D code Shielded cable Not required twisted pair is recommended Conductive housing Nickel plated zinc metal housings of X1 X8 also connected to the housing Number of ports 8 Ethernet X1 X8 Position Direction Description 1 Out Transmit Data 2 In Receive Data 3 Out Transmit Data 4 In Receive Data...

Страница 15: ...f Interface Ports LEDs LED indicators LED Status Description PWR GREEN Unit indicates no fault RED Unit indicated fault X1 to X8 OFF No Link GREEN Link is up GREEN FLASH Data is transmitted X1 X2 X6 X3 X7 PWR SERVICE X4 X8 X5 ...

Страница 16: ...ail This unit can be mounted on 35 mm DIN rail which is horizontally mounted inside an apparatus cabinet or similar Snap on mounting see figure Removal Press down the support at the back of the unit using a screwdriver See figure ...

Страница 17: ...airflow around the unit Spacing is recommended for the use of unit in full operating temperature range and service life Wall Mounting There are four 6 mm bore holes intended for mounting the unit The unit can be mounted vertical or horizontal Use four M6 screws with 12 mm washer on a flat and stable surface X1 X2 X6 X3 X7 PWR SERVICE X4 X8 X5 ...

Страница 18: ...18 6641 2211 Dimensions Measurements are stated in millimeters ...

Страница 19: ...19 6641 2211 ...

Страница 20: ...REV I 6641 2211 2022 08 Westermo Network Technologies AB Sweden Westermo Metallverksgatan 6 SE 721 30 Västerås Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com ...