background image

Multidropp 2-tråd

Multidrop 2-wire

Multidrop 2-Draht

Multipoints 2-fils

INSTALLATIONSANVISNING

INSTALLATION MANUAL

INSTALLATIONS ANLEITUNG

MANUEL D’INSTALLATION

6611-2021

www.westermo.com

TD-29P

FSK-modem

©

W

estermo 

Teleindustri 

AB 

• 

2003 

• 

REV

.A

Galvanic

Isolation

Transient

Protection

Balanced

Transmission

CE

Approved

Содержание TD-29 AC

Страница 1: ...tipoints 2 fils INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONSANLEITUNG MANUEL D INSTALLATION 6611 2021 www westermo com TD 29P FSK modem Westermo Teleindustri AB 2003 REV A Galvanic Isolation Transient Protection Balanced Transmission CE Approved ...

Страница 2: ...es 21 4 3 Environmental 21 4 4 Mechanical 21 5 Maintenance 22 6 Installation 22 26 6 1 Mounting Removal 22 6 2 Connections 23 6 3 LED Status Indicators 23 6 4 RS 485 Interface 24 6 5 Line Interface 24 6 6 Power Interface 24 6 7 Configuration 25 6 7 1 DIP switch settings 25 26 7 Functional description 27 28 7 1 Block diagram 27 7 2 RS 485 connection 27 7 3 Line connection 28 ...

Страница 3: ...al connections Installation This unit should only be installed by qualified personnel This unit should only be installed in a restricted access area for example a lockable cabinet where access is restricted to service personnel only This unit is intended for permanent connection to the AC DC mains supply The power supply wiring must be sufficiently fused and if necessary it must be possible to dis...

Страница 4: ...GB 18 6611 2021 2 1 Declaration of Conformity ...

Страница 5: ...ct DTE equipment can be connected through an RS 485 interface There are two baud rate settings The maximum bus length in multidrop configuration is dependent on the number of units connected TheTD 29P is designed to be used on dedicated lines and is not approved to European standard CTR 15 2 wire leased line PROFIBUS DP PROFIBUS DP PROFIBUS DP Dedicated Line Transmission Range speed point to point...

Страница 6: ...ted Connection 2 pos screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 RS 485 Electrical specification RS 485 Data rate 9 600 bit s 19 2 kbit s Connection Screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Circuit type TNV 1 FSK Line Electrical specification Data rate 9 600 bit s 19 2 kbit s Connection Screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Circuit type TNV 3 ...

Страница 7: ... 3 Environmental Temperature operating 5 50 C Temperature storage and transportation 40 to 85 C Relative humidity operating 0 to 95 non condensing Relative humidity 0 to 95 storage and transportation condensation allowed outside packaging 4 4 Mechanical Dimension W x H x D 55 x 100 x 128 mm Weight 0 5 kg Mounting 35 mm DIN rail Degree of protection IP 20 IEC 529 ...

Страница 8: ...ous voltages by disconnecting the unit from AC DC power supply and all others electrical connections Mounting This unit should be mounted on 35 mm DIN rail which is horizontally mounted on a wall or cabinet backplate This unit use convention cooling To avoid obstructions to the airflow around the unit use the following spacing rules Recommended spacing 25 mm 1 0 inch above below and 10 mm 0 4 inch...

Страница 9: ...D on Transmit line data active LED off Transmit line data inactive RD LED on Receive line data active LED off Receive line data inactive DCD LED on Data Carrier Detect active LED off Data Carrier Detect inactve 6 2 Connections Line connection Power supply RS 485 Interface LED indicators ...

Страница 10: ...ption Description 7 In Out A T Transmitter Receiver 6 In Out B T Transmitter Receiver Connection Description Description 1 0 VDC 2 12 36 VDC 6 4 RS 485 Interface 5 6 7 8 9 4 3 2 1 The definations R R T T can be varios between different manufactures 6 5 Line Interface 1 2 Transmitter Receiver Transmitter Receiver 6 6 Power Interface 1 2 ...

Страница 11: ...f the modem is removed Warning Do not open connected equipment Prevent access to hazardous voltages by disconnecting the unit from AC DC power supply and all others electrical connections NOTE When configuration via DIP switches the settings of DIP switches configure the unit only after a power reset A setting configured by any other method during normal operation override the DIP switch setting H...

Страница 12: ... Termination ON 1 2 3 4 5 6 7 8 Selection of transmission level S1 9 dBm ON 1 2 3 4 5 6 7 8 S1 5 dBm ON 1 2 3 4 5 6 7 8 Selection of minimum detection level S1 30 dBm ON 1 2 3 4 5 6 7 8 S1 20 dBm ON 1 2 3 4 5 6 7 8 S1 5 and 8 not used Load 600 Ω S2 No termination ON 1 2 3 4 S2 Termination ON 1 2 3 4 S1 ON 1 2 3 4 5 6 7 8 S2 ON 1 2 3 4 The line should be terminated at the end points The line should...

Страница 13: ...LED DCD LED B A Screw terminal 1 2 3 4 5 6 7 8 0V F1 0V 5V 5V 0V S2 4 S2 3 5V 0V 9 TD LED MCU 1 5 7 9 not used FSK Demodulator Insulateted Power Supply S1 4 0V 0V PWR LED Line switch Line Power Supply 2 wire 7 6 A A B B B B A A Twisted pair TD 29P RS 485 equipment Transmitter Receiver Transmitter Receiver ...

Страница 14: ... CTS DCD POWER LINE CONNECTION PWR TD RD RTS CTS DCD POWER LINE CONNECTION PWR TD RD RTS CTS DCD POWER LINE CONNECTION DCD 7 3 Line connection Multidrop half duplex with TD 29P 2 position detachable screw terminal Termination to be set with DIP switches ...

Страница 15: ...GB 29 6611 2021 OWN COMMENTS ...

Страница 16: ...or further information Westermo Data Communications Ltd Unit 14 Talisman Business Centre Duncan Road Park Gate Southampton SO31 7GA Phone 44 0 1489 580 585 Fax 44 0 1489 580586 E Mail sales westermo co uk Westermo Data Communications GmbH Goethestraße 67 68753 Waghäusel Tel 49 0 7254 95400 0 Fax 49 0 7254 95400 9 E Mail info westermo de Westermo Data Communications S A R L 9 Chemin de Chilly 91160...

Отзывы: