4.2.1 Factory Reset Adapter Specification
The factory reset adapter is a special plug for the Ethernet interface that activates the factory reset signal.
There is a specific factory reset adapter available:
FACTORY RESET PLUG D-CODED
Part No.: 3623-0795
Figure 17 Factory reset plug D-coded
4.2.2 Factory Reset Procedure
The Factory Reset is performed with a factory reset adapter that is connected to one of the Ethernet ports during
the start-up.
Step
Description
1.
Plug the factory reset adapter to one of the Ethernet interfaces.
2.
Power the device
3.
Wait until factory reset adapter is detected. This is indicated by an ORANGE operation LED in
combination with a RED status LED
4.
Remove factory reset adapter within 15 seconds
5.
A successful initiation of a factory Reset is indicated by an ORANGE BLINKING operation LED in
combination with a RED BLINKING failure LED
Table 20 Factory reset procedure
After successful factory reset, the dust cap must be closed to ensure the IP requirements.