background image

www.westermo.com

Lynx DSS L206-S2-EX 

Industrial Ethernet 6-port Device Server Switch

Содержание Lynx DSS L206-S2-EX

Страница 1: ...www westermo com Lynx DSS L206 S2 EX Industrial Ethernet 6 port Device Server Switch ...

Страница 2: ...2 6643 22901 ...

Страница 3: ...o can be found at www westermo com Software tools Related software tools are available at www westermo com support software tools License and copyright for included Free Libre Open Source Software This product includes software developed by third parties including Free Libre Open Source Software FLOSS The specific license terms and copyright associated with the software are included in each softwa...

Страница 4: ...s a potentially hazardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides information in order to avoid misuse of the product confusion or misunderstanding No personal injury Minor damage to the product NOTE Used for highlighting general but important inf...

Страница 5: ...rotective earthing terminal only valid for metallic housings Westermo recommends a cross sectional area of at least 4 mm2 If the product does not have a protective earthing terminal then the DINrail must be connected to protective earth Upon removal of the product ensure that the protective earthing conductor or the connection to earth via the DIN rail is disconnected last WARNING PROTECTIVE FUSE ...

Страница 6: ...n the gold plated connector pins CAUTION ELECTROSTATIC DISCHARGE ESD Prevent electrostatic discharge damages to internal electronic parts by discharging your body to a grounding point e g use a wrist strap CAUTION HOT SURFACE Be aware of that the surface of this product may become hot When it is operated at high temperatures the external surface may exceed Touch Temperature Limit according to the ...

Страница 7: ...gations Do not drop knock or shake the product Rough handling above the specification may cause damage to internal circuit boards Use a dry or slightly water damp cloth to clean the product Do not use harsh chemicals cleaning solvents or strong detergents Do not paint the product Paint can clog the product and prevent proper operation If the product is used in a manner not according to specificati...

Страница 8: ...evant requirements of EN 60079 0 and EN 60079 15 All external connections to the equipment and where applicable the SFP modules must not be inserted or removed unless either the area in which the equipment is installed is known to be non hazardous or the circuits connected have been de energized The network cables once installed must be properly fixated by the use of cable ties or similar to reduc...

Страница 9: ...079 15 erfüllt installiert werden Alle äußeren Anschlüsse des Gerätes und auch die SFP Module dürfen nur dann verbunden oder getrennt werden wenn entweder der Bereich in dem das Gerät installiert ist nachweislich ungefährlich ist oder die verbundenen Stromkreise spannungsfrei sind Die Netzwerkkabel müssen nach der Installation mithilfe von Kabelbindern oder ähnlichem Material ordnungsgemäß befesti...

Страница 10: ... et EN 60079 15 Toutes les connexions externes à l équipement et le cas échéant les modules SFP ne doivent pas être insérés ou retirés sauf si la zone dans laquelle l équipement est installé est reconnue comme non dangereuse ou si les circuits raccordés sont hors tension Une fois les câbles réseau installés ils doivent être correctement fixé grâce à des attaches de câbles ou autre élément semblabl...

Страница 11: ... cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or re...

Страница 12: ... equipement are used in safety critical applications such as tunnels traffic signal control and railway systems CAUTION CORROSIVE GASES If the product is placed in a corrosive environment it is important that all unused connector sockets are protected with a suitable plug in order to avoid corrosion attacks on the gold plated connector pins Declaration of Conformity Hereby Westermo declares that t...

Страница 13: ...ort U 1 V 4V μs I 20 mA Data rate 10 100 Mbit s No 2 TD In Out Transmitted Received data No 3 RD In Out Transmitted Received data No 4 Not Connected No 5 Not Connected No 6 RD In Out Transmitted Received data No 7 Not Connected No 8 Not Connected Shield Connected to PE Galvanically isolated via signal transformers and capacitively isolated to GND PE through a 2kV 1000pF capacitor USB Position Dire...

Страница 14: ...ive U 5 V max I 250 mA max Data rate 50 bit s 2 Mbit s No 2 T T R Out In RS 422 Transmit RS 485 Transmit Receive No 3 R In RS 422 Receive No 4 Not used No 5 Not used No 6 R In RS 422 Receive No 7 Not used No 8 Not used The product is equipped with internal termination that is configurable through software in RS 422 485 mode The following termination schemes are supported RS 422 RS 485 When the pro...

Страница 15: ...r cross section 0 2 2 5 mm2 AWG 24 12 Stripping length cable 7 mm Tightening torque terminal screw 0 5 0 6 Nm Tightening torque screw flange 0 3 Nm Shielded cable Not required Recommended external supply current capability for proper start up Ethernet TX Electrical specification IEEE std 802 3 2005 Edition Data rate 10 Mbit s 100 Mbit s manual or auto Duplex Full or half manual or auto Circuit typ...

Страница 16: ...Conductive housing Yes Number of ports 1 To minimise the risk of interference a shielded cable is recommended when the cable is located inside 3 m boundary or the cable is longer than 30 m and inside 10 m boundary to the rails and connected to this port I O Relay output Maximum voltage current 60 VDC 80 mA Contact resistance Max 30 Ω Isolation to All other ports Connection Detachable screw termina...

Страница 17: ...ode Circuit type SELV Maximum supply current 400 mA Connection USB receptacle connector type A Console Electrical specification LVTTL LVCMOS level Data rate 115 2 kbit s Data format 8 data bits no parity 1 stop bit no flow control Circuit type SELV Connection 2 5 mm jack use only Westermo cable 1211 2027 ...

Страница 18: ...2 Ω 0 5 μF Power frequency magnetic field EN 61000 4 8 Enclosure 300 A m 0 16 7 60 Hz 1000 A m 50 Hz Pulsed magnetic field EN 61000 4 9 Enclosure 300 A m Radiated RF immunity EN 61000 4 3 Enclosure 20 V m 80 2700 MHz 10 V m 2 7 6 GHz 1 kHz sine 80 AM Conducted RF immunity EN 61000 4 6 Power port 10 V 80 AM 1 kHz 0 15 80 MHz Ethernet Status out Digital in Serial ports Earth port Radiated RF emissio...

Страница 19: ... 2 6 sine Operating 3 13 2 Hz 1mm 13 2 100 Hz 0 7 g 5 5 30 Hz 1 5 g 30 50 Hz 0 42 mm 50 500 Hz 4 2 g IEC 60068 2 64 random 5 20 Hz 2 m s 20 2000 Hz 3 dB oct Shock IEC 60068 2 27 Operating 30 g 11 ms 100 g 6 ms Bump IEC 60068 2 27 Operating 10 g 11 ms x1000 Packaging Enclosure UL 62368 1 Zinc Fire enclosure Dimension W x H x D With connectors 52 5 x 100 x 101 mm 52 5 x 119 x 101 mm Weight 0 7 kg De...

Страница 20: ...t cable to your computer USB port if drivers are needed they can be downloaded from our Web page 3 Use a terminal emulator and connect with correct speed and format 115200 8N1 to the assigned port For more information about the CLI see the WeOS management guide I O connection Console port Cable 1211 2027 Bottom view Accessories Description Art no Westermo console cable 1211 2027 RJ45 to terminal b...

Страница 21: ...larm relay status contact Iin 80 mA max No 3 Digital in Input Digital in Uin 60 VDC max No 4 Digital in Input Digital in Iin 2 mA max The Status output is a potential free opto isolated normally closed solid state relay This can be configured to monitor various alarm events within the Lynx product see WeOS Management Guide An external load in series with an external voltage source is required for ...

Страница 22: ...ED No voltage present on DC2 FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT Error BLINK Product configured as FRNT Focal Point RSTP OFF RSTP disabled GREEN RSTP enabled BLINK Product elected as RSTP STP root switch USR1 OFF Configurable see WeOS Management Guide GREEN RED Rx TD TD OFF No serial data received GREEN FLASH Serial data received Tx RD RD OFF No serial data transmitted GREEN FLASH Serial...

Страница 23: ...ed DIN clip Removal Cooling This product uses convection cooling To avoid obstructing the airflow around the product use the following spacing rules Minimum spacing 25 mm 1 0 inch above below and 10 mm 0 4 inches left right the product Spacing is recommended for the use of product in full operating temperature range and service life 10mm 10mm This product has an integrated DIN clip To remove the p...

Страница 24: ...ine Management Tool in the WeOS management guide Factory default IP address 192 168 2 200 Netmask 255 255 255 0 Gateway Disabled Note If you are not sure about the subnet consult your network administrator Configuration Configure the product via web browser The product can easily be configured via a web browser Open the link http 192 168 2 200 in your web browser and you will be prompted with a lo...

Страница 25: ...ory default You now have the choice to go ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet cables The ON LED will stop flashing This initiates the factory reset process and the product will restart with factory default settings When the switch has booted up the ON L...

Страница 26: ...26 6643 22901 Dimensions Measurements are stated in millimeters 92 1 Min 4mm Max 7 5mm 34 1 96 1 52 1 100 1 ...

Страница 27: ...REV I 6643 22901 2020 12 Westermo Network Technologies AB Sweden Westermo SE 635 35 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com ...