2.5. Compliance Information
2.5.1. Agency Approvals and Standards Compliance
Type
Approval/Compliance
EMC
• EN/IEC 61000-6-1, Immunity residential environments
• EN/IEC 61000-6-2, Immunity industrial environments
• EN/IEC 61000-6-3, Emission residential environments
• EN/IEC 61000-6-4, Emission industrial environments
Environmental
• NEMA TS 2, Traffic Controller Assemblies with NTCIP Requirements
• AREMA
Safety
• EN/IEC/UL 61010-1, -2-201, Safety requirements for electrical equipment for
measurement, control, and laboratory use
Trackside
• EN 50121-4/IEC 62236-4, Railway signalling and telecommunications apparatus
Marine
• DNV GL rules for classification - Ships and offshore units
Table 2. Agency approvals and standards compliance
2.5.2. EN/IEC/UL 61010-2-201 Notice
This product has been tested and found compliant to EN/IEC/UL 61010-2-201, Safety
requirements for electrical equipment for measurement, control, and laboratory use. In
accordance with the definitions of the standard, this product shall be handled by skilled
service personnel.
2.5.3. AREMA
The product has been tested according to AREMA Part 11.3.3, 11.5.1 and 11.5.2.
Port
Test
Remark
DC Power
3 x U
N
, 80 ms
U
N
(max)=24 VDC when powered from a vital signal battery
Table 3. AREMA Part 11.3.3 C.4. - Signal equipment surge withstand capability for DC input port
Class C
Class D
Class E
Remarks
Temperature
X
X
X
Relative humidity
X
X
X
Vibration
X
X
X
Mechanical shock
X
X
X
Dielectric strength
X
Tested with 1.5 kVAC rms
Table 4. AREMA Part 11.5.1. - Environmental Class
8