background image

Industrial Ethernet  
SHDSL extender

www.westermo.com

DDW-222

1

2

TX

RX

DSL

©

W

estermo 

Teleindustri 

AB

User Guide

6642-22203

DDW-222 

W O L V E R I N E   S E R I E S

Содержание 3642-0220

Страница 1: ...Industrial Ethernet SHDSL extender www westermo com DDW 222 1 2 TX RX DSL Westermo Teleindustri AB User Guide 6642 22203 DDW 222 W O LV E R I N E S E R I E S ...

Страница 2: ...ity or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Under no circumstances shall Westermo be responsible for any loss of data or income or any special incidental and consequential or indirect damages howsoever caused More information about Westermo can be found at the following Internet address http www westermo com S...

Страница 3: ...in this unit when connected to power supply Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations This unit must not be operating with removed covers or lids Do not attempt to disassemble the unit There are no user serviceable parts inside Do not drop knock or shake the unit rough handling above the specification may ca...

Страница 4: ...Out TD 3 In Out RD 4 Not connected 5 Not connected 6 In Out RD 7 Not connected 8 Not connected Galvanically isolated via signal transformers and capacitively isolated to signal ground through a 2 kV 1000 pF capacitor See user manual for proven transient protection Pos Direction descripton Input Output values 1 Not connected DCD Umax 12 Vpk Imax 60 mA Data rate 0 3 115 2 kbit s 2 In Received Data R...

Страница 5: ...comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful inter...

Страница 6: ... in electrical and electronic equipment RoHS References of standards applied for this EU declaration of conformity No Title Issue EN 61000 6 1 Electromagnetic compatibility Immunity for residential environments 2007 EN 61000 6 2 Electromagnetic compatibility Immunity for industrial environments 2005 EN 61000 6 3 Electromagnetic compatibility Emission residential environments 2007 EN 61000 6 4 Elec...

Страница 7: ...ports 250 V 50 Hz line to line Voltage dips and interruption EN 61000 4 29 DC power ports 10 ms interruption 10 ms 30 reduction 10 ms 60 reduction 20 above 20 below rated voltage Radiated emission CISPR 16 2 3 ANSI C63 4 FCC part 15 Enclosure Class A Class A Conducted emission CISPR 16 2 1 DC power ports Class B Dielectric strength EN 60950 Signal port to other isolated ports 1500 Vrms 50 Hz 1 min...

Страница 8: ...ng a web interface The DIN rail mounted DDW 222 is designed for harsh environments and can be used in industrial and railway applications It can be powered from two separate supplies and handle an operating voltage range of 16 60 VDC RS 232 serial adapter 10 port Virtual Com software Redundant protocol FRNT on SHDSL or on the Ethernet switch 192 kbit s to 5 7 Mbit s Over 10 km 6 2 miles on twisted...

Страница 9: ...r size 0 2 2 5 mm2 AWG 24 12 Shielded cable Not required If external power supply is used it must meet specified inrush current SHDSL Electrical specification ITU T G 991 2 Annex B Data rate 192 kbit s to 5696 kbit s Protocol EFM according to IEEE 802 3 2004 Transmission range According to ITU T G 991 2 depending on the line quality Protection Overcurrent overvoltage protection circuit and varisto...

Страница 10: ...d close to rails Number of ports 4 ports marked as 1 2 3 4 To minimise the risk of interference a shielded cable is recommended when the cable is located inside 3 m boundary to the rails and connected to this port RS 232 Electrical specification EIA RS 232 Data rate 300 bit s to 115 2 kbit s Data format 7 or 8 data bits odd even or none parity 1 or 2 stop bits Protocol Transparent optimised by pac...

Страница 11: ...Out 2 wire Receive Transmit SHDSL 2 In Out 2 wire Receive Transmit SHDSL Ethernet TX connection RJ 45 connector 1 4 Position Direction Description 1 In Out TD 2 In Out TD 3 In Out RD 4 Not Connected 5 Not Connected 6 In Out RD 7 Not Connected 8 Not Connected CAT 5 cable is recommended Unshielded UTP or shielded STP connectors can be used LED indicators for details see next page LED indicators also...

Страница 12: ... 1 4 Green LED OFF No link ON Link active Flashing Traffic on link 10 100BASE TX Port 1 4 Yellow LED OFF No port alarm ON Port alarm TX OFF No serial data transmitted Flashing green Serial data transmitted from the unit RX OFF No serial data received Flashing green Serial data received to the unit DSL Port 1 2 OFF No link ON green Link established ON red Unit is booting Flashing green Link negotia...

Страница 13: ...application one unit must be configured as focal point all other units will be configured as members Connect DSL 1 to DSL 2 on the following units to obtain a chain of linked units DDW 222 1 2 TX RX DSL DDW 222 1 2 TX RX DSL DDW 222 1 2 TX RX DSL DDW 222 1 2 TX RX DSL Connect DDW 120 to DDW 22x In an SHDSL connection one unit shall be configured as CO Central Office and one as CPE Customer Premise...

Страница 14: ...IP Configuration program is available on the CD or for download from the WESTERMO web page http www westermo com choose Downloads Software Ethernet Ethernet switches Name setup exe Install the software and start the application from a PC on the network connected to where the DDW 2XX is installed Make sure that the Default IP of the configuration software see figure below is in the same subnet as y...

Страница 15: ...he list Now you can access the DDW 2XX via the browser for further configuration by clicking the unit with an IP address that fits your subnet Figure 2 will appear and now you click the OK button and a web browser will be opened and redirected to the DDW 2XX unit login page figure 5 Figure 2 Access switch via web Cancel OK IP configuration Click the Close button to get back to main view You will t...

Страница 16: ...ternet standard protocol IP developed to manage IP nodes servers workstations routers switches and hubs etc on an Ethernet network SNMP enables network administrators and control engineers to manage network performance find and solve network problems and plan for network growth The DDW 2XX MIB s are divided into groups allowing the SNMP manager to poll the SNMP agents for information Figure 5 Log ...

Страница 17: ... 1 to port 4 2 Connect Ethernet cable from port 2 to port 3 3 Power up the unit 4 Wait for the unit to start up Control that the PWR led is flashing green The PWR flashing indicates that the unit will be set to factory default 5 Remove the Ethernet cables the unit will automatically start with factory default settings Note The Ethernet cables must be removed within 30 seconds from power up or the ...

Страница 18: ...nting points CLICK PWR FRNT 10 100 BASE TX 1 3 2 4 DSL 1 DSL 2 POWER DSL 1 DSL 2 This unit can also be wall mounted see figure PWR FRNT 10 100 BASE TX 1 3 2 4 DSL 1 DSL 2 POWER DSL 1 DSL 2 PWR FRNT 10 100 BASE TX 1 3 2 4 DSL 1 DSL 2 POWER DSL 1 DSL 2 25 mm 25 mm Cooling This unit uses convection cooling To avoid obstructing the airflow around the unit use the following spacing rules Minimum spacin...

Страница 19: ...19 6642 22203 ...

Страница 20: ...de North America info westermo com www westermo com Singapore sales westermo com sg www westermo com Sweden info sverige westermo se www westermo se United Kingdom sales westermo co uk www westermo co uk Other Offices Sales Units Westermo Data Communications Westermo SE 640 40 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com REV C 6642 22203 2016 ...

Отзывы: