Unmanaged EN 50155 Switch

Содержание 3641-0540

Страница 1: ...www westermo com Viper 012 Unmanaged EN 50155 Switch...

Страница 2: ...2 6641 22410...

Страница 3: ...ressed or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose Westermo reserves the right to revise this document or withdraw it at any...

Страница 4: ...a potentially hazardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product...

Страница 5: ...ousings Westermo recommends a cross sectional area of at least 4 mm2 Upon removal of the product ensure that the protective earthing conductor is disconnected last WARNING HAZARDOUS VOLTAGE Do not ope...

Страница 6: ...t high temperatures the external surface may exceed Touch Temperature Limit according to the product s relevant electrical safety standard CAUTION ELECTROSTATIC DISCHARGE ESD Prevent electrostatic dis...

Страница 7: ...rking properly contact the place of purchase nearest Westermo distributor office or Westermo technical support Product disposal This symbol means that the product shall not be treated as unsorted muni...

Страница 8: ...sted and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a...

Страница 9: ...GHz Conducted RF emission CISPR 16 2 1 Power port Class B Ethernet ports Class B Dielectric strength EN 60950 1 Power port to all other ports 1 5 kV ACrms 50 Hz 1 min Fast Ethernet ports to all other...

Страница 10: ...to IP67 and vibration resistant to and exceeding on board rail standards this unit is ideal for situations where mechanical stress moisture condensation dirt or continuous vibrations could adversely a...

Страница 11: ...dimensions depend on choice of M12 connector External supply current capability for proper start up X1 X12 Ethernet ports Electrical specification IEEE std 802 3 2005 Edition Data rate 10 Mbit s 100 M...

Страница 12: ...6641 22410 Location of interface ports and LED DC SRV 1 SRV 2 X1 X5 X9 X6 X10 X7 X11 X8 X12 X2 X3 X4 Ethernet connection TX Power connection LED indicators Earth connection For Westermo internal use o...

Страница 13: ...X2 X3 X4 DC OFF Unit has no power GREEN Power OK on DC1 and DC1 RED Power failure on DC1 or DC2 X1 to X12 OFF No Link GREEN Link established GREEN FLASH Data traffic indication YELLOW Port alarm and n...

Страница 14: ...rew the unit from the wall Time For Replacement 15 minutes Cooling This unit relies on convection cooling Make sure that it is installed so that the ambient temperature is within the specified tempera...

Страница 15: ...24 23 3 48 48 8 73 5 72 14 54 1 1 65 4 1 Material Remark Designation Dimension Description Quantity Pos No 1 1 Scale Status Designer Drawing No PaPu Approved 6001 0001 U 01 Sheet 1 1 Denomination Vipe...

Страница 16: ...Westermo SE 640 40 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com REV B 6641 22410 2021 06 Westermo Network Technologies AB Sweden...