background image

www.westermo.com

         

  

               

                            

OS

Viper-208-TBN Series

Managed EN 50155 Backbone Routing Switch

Содержание 3635-2020

Страница 1: ...www westermo com OS Viper 208 TBN Series Managed EN 50155 Backbone Routing Switch ...

Страница 2: ...rt 15 105 Class A Notice 8 2 5 3 Simplified Declaration of Conformity 8 3 Product Description 9 3 1 Product Description 9 3 2 Available Models 9 3 3 Hardware Overview 10 3 4 Connector Pinout 11 3 5 Bypass Functionality 12 3 6 LED Indicators 15 3 7 Dimensions 16 4 Installation 17 4 1 Wall Mounting 17 4 2 Protective Earth Connection 17 4 3 Connection of Cables 18 4 4 Cooling 19 4 5 Replacement of Pr...

Страница 3: ...users of the Westermo products It includes information on safety and regulations a product description installation instructions and technical specifications 1 3 Software Tools Related software tools are available at www westermo com support software tools 1 4 License and Copyright for Included FLOSS This product includes software developed by third parties including Free Libre Open Source Softwar...

Страница 4: ...ardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides information in order to avoid misuse of the product confusion or misunderstanding No personal injury Minor damage to the product NOTE Used for highlighting general but important information No persona...

Страница 5: ...cross sectional area of at least 4 mm2 Upon removal of the product ensure that the protective earthing conductor is disconnected last WARNING HAZARDOUS VOLTAGE Do not open an energised product Hazardous voltage may occur when connected to a power supply WARNING PROTECTIVE FUSE The power supply wiring must be sufficiently fused The fuse must be IEC 60127 certified and rated for T1 6 A and 250 V It ...

Страница 6: ...e range NOTE MECHANICAL FORCE ON VENTILATION MEMBRANE Do not cover or bring mechanical force to the ventilation membrane on the back of the product 2 3 Care Recommendations Follow the care recommendations below to maintain full operation of the product and to fulfill the warranty obligations Do not drop knock or shake the product Rough handling above the specification may cause damage to internal ...

Страница 7: ...C EN IEC 61000 6 2 Immunity industrial environments EN IEC 61000 6 4 Emission industrial environments EN 50121 4 IEC 62236 4 Railway signalling and telecommunications apparatus EN 50121 3 2 IEC 62236 3 2 Railway applications Rolling stock apparatus Tested and verified for Class S1 DB EMC Regulation 06 Commodity team Radio compatibility in VDB Rev 1 0 Shunting Radio Tested and verified for FCC part...

Страница 8: ...th the user manual may cause harmful interference to radio communications Operation of this product in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the users own expense 2 5 3 Simplified Declaration of Conformity Hereby Westermo declares that this product is in compliance with applicable EU directives and UK legis...

Страница 9: ...r easy integration and low lifecycle cost Thorough type testing at independent ISO IEC 17025 and ILAC MRA certified labs accredited to a wide range of standards show that the Viper series fulfills EN 50155 and other requirements The state of the art Westermo production facility ensures the quality of each individual unit e g through temperature cycling burn in testing The WeOS operating system off...

Страница 10: ...D indicators No Description No Description 1 LED indicator 2 1 Gbps port double ring symbol on front of product see table below 3 GORE TEX ventilation membrane on the rear side 4 100 Mbps port single ring symbol on front of product see table below 5 Power connection 6 Console port 7 Protective earth connection 8 USB port Model Mbps ports Gbps ports Viper 208 T4G TBN X5 to X7 X1 to X4 Viper 208 T8G...

Страница 11: ...tive inputs are DC1 and DC2 The negative input for both supplies is COM Table 4 Power connector Pin no Signal Illustration 1 NCa 2 TX 3 RX 4 NCa 5 GND aNo Connect Do not connect Table 5 Console connector Pin no Signal Illustration 1 DN 2 VBUS 3 NCa 4 DC 5 GND aNo Connect Do not connect Table 6 USB connector Viper 208 TBN Series 11 ...

Страница 12: ...Gbps connector 3 5 Bypass Functionality The bypass functionality secures connection backbone traffic in case of power failure by bridging the two pairs of ports normally connected to the backbone The ports are cross coupled when in bypass This is since the main use cases require the use of fixed MDI MDIX settings During power loss and connection of the two adjacent switches the intent is to compen...

Страница 13: ...3 X6 2 X8 4 X6 3 X8 1 X6 4 X8 2 Table 9 Bypass interfaces Viper 208 T8G TBN internal bypass X5 1 connected to X7 3 X5 2 X7 4 X5 3 X7 1 X5 4 X7 2 X5 5 X7 8 X5 6 X7 7 X5 7 X7 6 X5 8 X7 5 X6 1 X8 3 X6 2 X8 4 X6 3 X8 1 X6 4 X8 2 X6 5 X8 8 X6 6 X8 7 X6 7 X8 6 X6 8 X8 5 Table 10 Bypass interfaces Viper 208 TBN Series 13 ...

Страница 14: ... TBN When bypassing a switch approximately 5 m 16 ft of the transmission range 100 m 300 ft is consumed As an example if a network is intended to cope with a single car blackout scenario and that two Vipers in that case will be by passed the total cable distance through the blackout car to adjacent switches on each side of the blackout car should not exceed 90 m 300 ft Normally the Viper can handl...

Страница 15: ... factory reset RSTP OFF RSTP disabled GREEN RSTP enabled BLINK Product selected as RSTP STP root switch FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT error BLINK Product configured as FRNT focal point DC OFF Product has no power GREEN Power OK on DC1 and DC2 RED Power failure on DC1 or DC2 X1 to X8 OFF No link GREEN Link established GREEN FLASH Data traffic indication YELLOW Port alarm or port is ...

Страница 16: ...ensions Dimensions are stated in mm and are regardless of model 164 0 5 100 7 2 0 2 0 5 56 0 3 82 5 29 5 72 37 7 4 0 5 175 31 5 Grounding point Screw M5x10 Figure 5 Dimensional drawing 16 Viper 208 TBN Series ...

Страница 17: ...s with 12 mm washers on a flat and stable surface X5 X7 Bypass 1 DC CON FRNT RSTP ON USB X1 X8 X2 X3 X4 X6 24 110 V M12 Torque 0 6 0 1 Nm 0 45 0 1 lbft DC L1 L2 Bypass 2 Figure 6 Wall mounting 4 2 Protective Earth Connection For correct function the earth connection needs to be properly connected to a designated PE rail See the figure below Viper 208 TBN Series 17 ...

Страница 18: ...to the unit WARNING PROTECTIVE FUSE The power supply wiring must be sufficiently fused The fuse must be IEC 60127 certified and rated for T1 6 A and 250 V It must be possible to disconnect manually from the power supply Ensure compliance to national installation regulations This product has no internal fuse and should be connected via an external fuse for protection NOTE UNUSED CONNECTORS Unused c...

Страница 19: ...the USB port and move it over to the replacement product before it is powered up MTTR Mean Time To Repair i e time for replacement of product is 8 minutes CAUTION HOT SURFACE Be aware that the surface of this product may become hot When it is operated at high temperatures the external surface may exceed Touch Temperature Limit according to the product s relevant electrical safety standard This pro...

Страница 20: ... input Yes Isolation To all other ports Connector 4 pin male M12 screw connection A coded recommended Westermo cables 3146 1106 for 1 5 m 3146 1107 for 5 m Cable size M12 recommended power cable area 0 5 mm minimum 0 25 mm which correlates to AWG 21 or larger Cable dimensions depend on choice of M12 connector Cable temperature rating For minimum temperature rating of the cable to be connected to t...

Страница 21: ... TNV 1 a100 Mbps ports are ports X5 X8 on Viper 208 T4G TBN bIn case of bypass no isolation between X5 to X7 and X6 to X8 Gbps portsa Electrical specification IEEE std 802 3 Data rate 10 Mbps 100 Mbps 1 Gbps manual or auto Duplex Full or half manual or autob Transmission range Up to 150 m with CAT5e cable or better Isolation To all other portsc Connector 8 pin female M12 screw connection X coded C...

Страница 22: ...nnection A coded recommended Westermo USB plug 3641 0190 Circuit type SELV Console port Electrical specification RS 232 Data rate 115 2 kbit s Data format 8 data bits no parity 1 stop bit no flow control Isolation To all Ethernet and DC ports No isolation to USB or protective earth Connector 5 pin female M12 screw connection B coded recommended Westermo cables 1211 2215 serial port or 1211 4073 US...

Страница 23: ... AM Conducted RF immunity EN 61000 4 6 Power port 10 V 80 AM 1 kHz 0 15 80 MHz Ethernet ports Earth port Radiated RF emission CISPR 16 2 3 Enclosure EN 61000 6 4 30 6000 MHz ANSI C63 4 FCC Part 15b Class A Conducted RF emission CISPR 16 2 1 Power port EN 61000 6 4 CISPR 32 Ethernet ports EN 61000 6 3 Insulation resistance EN 50155 All ports 20 MΩ at 500 VDC Dielectric strength EN 50155 Power port ...

Страница 24: ...tional Shock IEC 60068 2 27 Operational 10 g 30 ms half sine 20 g 11 ms saw tooth Weight 1 5 kg Degree of protection IEC 60529 Enclosure IP67 no ingress of dust and protection against water immersion up to 1 m Also passes IP66 tests c Cooling Convection Overvoltage category EN IEC 61010 1 OVC II Pollution degree EN IEC 61010 1 PD3 macro environment and PD2 micro environmentd EN 50124 1 PD2 Locatio...

Страница 25: ...ests and Environmental Conditions updated Rev D 2020 06 2 2 Safety information warnings updated 3 Product description updated Rev C 2020 05 1 5 WeOS updated 2 2 Safety Information text and warnings updated 2 3 Care Recommendations updated old 2 4 Maintenance deleted 2 5 1 Agency Approvals and Standards Compliance updated 3 3 Hardware Overview illustration updated 4 1 Wall Mounting illustration add...

Страница 26: ...Viper 208 TBN Series ...

Страница 27: ...Viper 208 TBN Series ...

Страница 28: ...Westermo Metallverksgatan 6 SE 721 30 Västerås Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com 6635 2200 REV E 2021 05 Westermo Network Technologies AB Sweden ...