background image

www.westermo.com

         

  

               

                            

OS

Viper 20A-PoE Series

20 port Ethernet M12 switches with Power over Ethernet

Содержание 3635-1010

Страница 1: ...www westermo com OS Viper 20A PoE Series 20 port Ethernet M12 switches with Power over Ethernet ...

Страница 2: ...liance 8 2 5 2 FCC Part 15 105 Class A Notice 8 2 5 3 Simplified Declaration of Conformity 9 3 Product Description 10 3 1 Product Description 10 3 2 Available Models 10 3 3 Hardware Overview 12 3 4 Connector Pinout 13 3 5 LED Indicators 15 3 6 Dimensions 16 4 Installation 17 4 1 Wall Mounting 17 4 2 Protective Earth Connection 17 4 3 Connection of Cables 18 4 4 Cooling 19 4 5 Replacement of Produc...

Страница 3: ...stermo products It includes information on safety and regulations a product description installation instructions and technical specifications 1 3 Software Tools Related software tools are available at www westermo com support software tools 1 4 License and Copyright for Included FLOSS This product includes software developed by third parties including Free Libre Open Source Software FLOSS The spe...

Страница 4: ...ardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides information in order to avoid misuse of the product confusion or misunderstanding No personal injury Minor damage to the product NOTE Used for highlighting general but important information No persona...

Страница 5: ...uct can be connected to two different power sources Upon removal of the product ensure that the protective earthing conductor is disconnected last WARNING HAZARDOUS VOLTAGE Do not open the connected product Hazardous voltage may occur within this product when connected to power supply WARNING PROTECTIVE FUSE The power supply wiring must be sufficiently fused The fuse must be IEC 60127 certified an...

Страница 6: ...ures the external surface may exceed Touch Temperature Limit according to the product s relevant electrical safety standard This product complies with Touch Temperature Limits throughout its operational temperature range NOTE MECHANICAL FORCE ON VENTILATION MEMBRANE Do not cover or bring mechanical force to the ventilation membrane on the back of the product NOTICE ADDITIONAL EMC TYPETESTS For add...

Страница 7: ...t is not working properly contact the place of purchase the nearest Westermo distributor office or Westermo technical support 2 4 Product Disposal This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment By ensuring the product is disposed o...

Страница 8: ...ations Insulation coordination EN 50155 IEC 60571 Railway applications Electronic equipment used on rolling stock Fire protection EN 45545 2 Fire protection on railway vehicles NFPA 130 Fire protection for fixed guideway transit and passenger rail system aApplicable only for Viper x20A P8 LV and Viper x20A T4G P8 LV Table 2 Agency approvals and standards compliance 2 5 2 FCC Part 15 105 Class A No...

Страница 9: ...is in compliance with applicable EU directives and UK legislations The full declaration of conformity and other detailed information is available at www westermo com support product support Figure 2 The European Conformity and the UK Conformity Assessment markings Viper 20A PoE Series 9 ...

Страница 10: ...h MTBF for easy integration and low lifecycle cost Thorough type testing at independent ISO IEC 17025 and ILAC MRA certified labs accredited to a wide range of standards show that the Viper series fulfills EN 50155 and other requirements The state of the art Westermo production facility ensures the quality of each individual unit e g through temperature cycling burn in testing The WeOS operating s...

Страница 11: ... 110 V 3635 1110 Viper 120A P8 LV L2 24 38 V 3635 1410 Viper 120A T4G P8 LV L2 4 24 38 V 3635 1020 Viper 220A P8 HV L3 48 110 V 3635 1320 Viper 220A T4G P8 HV L3 4 48 110 V 3635 1120 Viper 220A P8 LV L3 24 38 V 3635 1420 Viper 220A T4G P8 LV L3 4 24 38 V Table 3 Available Viper x20A P8 models Viper 20A PoE Series 11 ...

Страница 12: ...10 V DC X14 X20 X12 X18 X9 X3 X15 PoE 1000BASE T 1 2 4 6 7 9 8 3 5 No Description No Description 1 LED indicator 2 100 Mbps port 3 100 Mbps PoE port 4 Gbps ports 5 Gbps PoE port 6 Power connection 7 Console port 8 USB port 9 Protective earth connection Figure 3 Location of interface ports and LED indicators 12 Viper 20A PoE Series ...

Страница 13: ...ribute the current over two pins Table 4 Power connector HV Pin no Signal Illustration 1 DC1 3 1 2 4 2 DC1 3 COM 4 COM The Viper 20A PoE series has single power connection Dual pins shall be connected to the power supply DC1 for positive terminal COM for negative terminal in order to distribute the current over two pins Table 5 Power connector LV Pin no Signal Illustration 1 NC 2 TX 3 RX 4 NC 5 GN...

Страница 14: ...gnal Illustration 1 TD 2 RD 3 TD 4 RD MDI MDI X and auto MDI MDI X modes are supported The table shows signals in MDI mode Table 8 100 Mbps Ethernet connector Pin no Signal Illustration 1 DA 1 2 3 4 5 6 7 8 2 DA 3 DB 4 DB 5 DD 6 DD 7 DC 8 DC Table 9 Gbps connector 14 Viper 20A PoE Series ...

Страница 15: ...P disabled GREEN RSTP enabled BLINK Product selected as RSTP STP root switch FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT error BLINK Product configured as FRNT focal point DC OFF Product has no power GREEN Power OK Input voltage 70 of minimum nominal voltage RED Power failure Input voltage 70 of minimum nominal voltage X1 to X20 OFF No link GREEN Link established GREEN FLASH Data traffic indicat...

Страница 16: ... 6 Dimensions Dimensions are stated in mm and are regardless of model 83 110 178 3 5 1 0 5 Grounding point Screw M5x10 164 0 5 56 0 3 7 2 0 2 0 5 160 Figure 4 Dimensional drawing 16 Viper 20A PoE Series ...

Страница 17: ...hers on a flat and stable surface M12 Torque 0 6 0 1 Nm 0 45 0 1 lbft X11 X17 X10 X16 X2 ON FRNT CON RSTP USB DC X5 X1 X4 X7 X6 X13 X19 X8 48 110 V DC X14 X20 X12 X18 X9 X3 X15 PoE RING Figure 5 Wall mounting 4 2 Protective Earth Connection For correct function the earth connection needs to be properly connected to a designated PE rail See the figure below Viper 20A PoE Series 17 ...

Страница 18: ...cting the power cable ensure that the pins are connected correctly before tightening the power cable to the unit WARNING PROTECTIVE FUSE The power supply wiring must be sufficiently fused The fuse must be IEC 60127 certified and rated for T6A HV models or T10A LV models and 250 V It must be possible to disconnect manually from the power supply Ensure compliance to national installation regulations...

Страница 19: ...of the original product it is recommended to have the Westermo USB plug permanently connected to the USB port and move it over to the replacement product before it is powered up MTTR Mean Time To Repair i e time for replacement of product is 15 minutes CAUTION HOT SURFACE Be aware that the surface of this product may become hot When it is operated at high temperatures the external surface may exce...

Страница 20: ...input No Isolation 2250 VDC to all other ports Circuit type Secondary circuit hazardous voltage OVC II Connector Viper x20A PoE LV units 4 pin male M12 T coded recommended Westermo cable 3146 1109 for 5 m Viper x20A PoE HV units 4 pin male M12 A coded recommended Westermo cables 3146 1106 for 1 5 m 3146 1107 for 5 m Cable size For Viper x20A PoE HV units M12 recommended power cable area 0 5 mm min...

Страница 21: ...onfiguration time Typically below 20 ms a100 Mbps ports non PoE are X1 X4 X8 X10 X14 X16 X19 X20 on Viper x20A P8 HV LV X1 X4 X9 X10 X15 X16 X19 X20 on Viper x20A T4G P8 HV LV b750 VDC after damp heat according to EN 50155 Gbps ports non PoEa Electrical specification IEEE std 802 3 Data rate 10 Mbps 100 Mbps 1000 Mbps manual or auto Circuit type TNV 1 Transmission range Up to 100 m with CAT5e cabl...

Страница 22: ...wered Device is depending on the cable resistance NOTE PoE ports are not isolated to each other USB port Electrical specification USB 2 0 host interface Data rate Up to 480 Mbps high speed mode Maximum supply current 500 mA Circuit type SELV Isolation To all Ethernet and DC ports No isolation to CON or protective earth Connector 5 pin female M12 A coded recommended Westermo USB plug 3641 0190 Cons...

Страница 23: ...t 2 6 GHz 1 kHz sine 80 AM Conducted RF immunity EN 61000 4 6 Power port 10 V 80 AM 1 kHz 0 15 80 MHz Ethernet ports Earth port Radiated RF emission CISPR 16 2 3 Enclosure EN 61000 6 4 80 6000 MHz ANSI C63 4 FCC Part 15 EN 61000 6 4 80 6500 MHz Conducted RF emission CISPR 16 2 1 Power port EN 61000 6 4 Ethernet ports EN 61000 6 3 Dielectric strength EN 60950 1 Power port to all other ports 2250 VD...

Страница 24: ...Hz 5 sweeps IEC 60068 2 64 random Non operational long life simulation 11 44 m s rms 5 150 Hz 5 hours Shock IEC 60068 2 27 Operational 10 g 30 ms half sine 20 g 11 ms saw tooth 100 g 6 ms half sine Weight 2 5 kg Degree of protection EN 60529 Enclosure IP67 Cooling Convection Overvoltage category EN IEC 61010 1 OVC II Pollution degree EN IEC 61010 1 PD3 macro environment and PD2 micro environmentc ...

Страница 25: ...cy Approvals and Standards Compliance references to SBB requirements and ÖBB removed Rev D 2019 09 2 6 1 Agency Approvals and Standards Compliance updated with E mark Rev C 2019 06 Front page updated 1 3 Software Tools text updated 2 2 Safety Information Notice Mechanical force on ventilation membrane new information 2 3 Care Recommendations text updated 4 4 Replacement of Product text updated Rev...

Страница 26: ...Viper 20A PoE Series ...

Страница 27: ...Viper 20A PoE Series ...

Страница 28: ...Westermo Metallverksgatan 6 SE 721 30 Västerås Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com 6641 22521 REV G 2021 05 Westermo Network Technologies AB Sweden ...

Отзывы: