Westermann Cleanmeleon II
Westermann GmbH & Co. KG
29
max. 5 l
min. 3 l
Dip-
stick
Nut
5. Hydraulic controls
Needle valve for regulating the oil flow through the hydraulic lifting
mechanism.
Left lever:
Push the lever forward = brush rotates right
Pull the lever backward = brush rotates left
Right lever:
Push the lever forward = lower attachment
Pull the lever backward = raise attachment
5.1. Hydraulic oil quantity (standard)
Needle valve:
Optional:
Right lever
Left lever
The oil level is checked using a dipstick!
Pull out dipstick: Oil level max. up to the
nut and min. approx. 3-4 cm below!
Caution