Section 311-580-20B
030-101527 Rev. B
15
0407IBRB
Figure 15. Provisioning Menu Screen
PROVISIONING MENU
Option
Current
New
>
Monitored Line Coding:
B8ZS
AMI
Monitored Framing:
ESF
CPE LOS Response:
AIS-CI
RAI-CI Option:
ENABLED
Real Time PM mode
NPRM/SPRM
CPE-to-FAC Regen:
REGEN ON
CPE-to-FAC LBO:
DISABLED
FAC-to-CPE Regen:
REGEN OFF
FAC-to-CPE LBO:
DISABLED
Loopback Timeout:
120 MINUTE
Loopback Mode
NORMAL
Circuit ID:
<UNASSIGNED>
SELECTIONS
S) Save
D) Set to default settings
Use <tab> to select option, <space> to change, or Esc to return to main menu
Westell B90-311580
CLEI: T1S1ABTAAA
Field/Option
Parameter
Default*
Description
Monitored Line Coding
AMI
Configures unit for AMI line coding.
g
(Note 1)
B8ZS
Configures unit for B8ZS line coding.
Monitored Framing
SF
Monitors SF parameters for PM.
g
ESF
Monitors ESF parameters for PM.
CPE LOS Response
None
No response to customer LOS.
p
LB
Enters loopback toward Network upon detecting a Customer LOS.
Idle
Send Idle toward Network upon detecting a customer LOS.
AIS
Send AIS toward Network upon detecting a Customer LOS.
AIS-CI
Send AIS-CI toward Network upon detecting a Customer LOS.
RAI-CI Option
Enabled
Converts customer RAI to RAI-CI if also receiving a valid network signal.
p
Disabled
RAI from CPE is always passed unchanged.
Real-Time Mode
None
Disables real-time reporting.
NPRM
Configures the unit to send NPRM messages.
SPRM
Configures the unit to send SPRM messages.
SPRM/NPRM
Configures the unit to send both SPRM and NPRM messages.
CPE-to-FAC REGEN
Regen Off
No regeneration in the CPE-to-FAC (Z-A, XMT) path.
Regen On
Regeneration in the CPE-to-FAC path.
CPE-to-FAC LBO
Disabled
Select this option to disable the CPE-to-FAC LBO.
7.5 dB
Select this option to select 7.5 dB of LBO.
15 dB
Select this option to select 15 dB of LBO.
22.5 dB
Select this option select 22.5 dB of LBO.
AB15 dB
Select this option if the Auto Binder level of the cable is 15 dB.
AB22.5 dB
Select this option if the Auto Binder level of the cable is 22.5 dB.
FAC-to-CPE REGEN
Regen Off
No regeneration in the FAC-to-CPE (A-Z, RCV) path.
Regen On
Regeneration in the FAC-to-CPE path (0 dB DSX hand-off).
FAC-to-CPE LBO
Disabled
Select this option to disable the FAC-to-CPE LBO.
7.5 dB
Select this option to select 7.5 dB of LBO.
15 dB
Select this option to select 15 dB of LBO.
Loopback Time-out
Disabled
Loopback will not time-out.
p
20 Minute
Loopback will automatically time-out 20 minutes after initial activation.
60 Minute
Loopback will automatically time-out 60 minutes after initial activation.
120 Minute
Loopback will automatically time-out 120 minutes after initial activation.
24 Hour
Loopback will automatically time-out 1440 minutes after initial activation.
Loopback Mode
Normal
Unit loops up to normal inband/Data Link loopback codes.
p
Addressed
Unit loops up to unique 16-bit addressed loopback code.
Circuit ID
<user defined>
This field can be up to 20 alphanumeric characters (user defined).
Table 7. Options and Parameters