CS40-734834-00D-A0 Product Manual
April 2020, Rev A
WESTELL.COM
© 2019 Westell Technologies
April 2020; Doc No. CS14702802UM rD
1.877.844.4274
Page 26 of 52
3.4 Environmental Specification
Table 3-4: Environmental Specifications
Parameter
Specification
Note
Operating Temperature
-30°C ~ +50°C (ambient)
-22°F ~ +122°F
Storage Temperature
-40°C ~ +60°C (ambient)
-40°F to +140°F
Operating Humidity
5% ~ 95%
Environmental
IP-67, NEMA 4 Compliance
3.5 GUI Items
Table 3-5: GUI Items
Parameter
Specification
Note
UL/DL Output Readings
UL : 5dBm to 30dBm
DL : 5dBm to 36dBm
Reads and displays the UL/DL output power
Alarm Readout Displays
Loss of AC Power - Battery Depleted
Donor Antenna Fail1
Oscillation Detection1
Temperature Fail
UL/DL Amplifier Fail
Donor Antenna Fail2
Oscillation Detection2
Loss of Ra/DRA COMMS
Battery Charger Fail
Door Open
Emergency Power Off
Displays alarm status
UL/DL Shutdown Setting
UL : 30dBm
DL : 36dBm
Use to set the peak power
(shutdown level)
UL/DL Gain Setting
/ Attenuation
UL : 50dB to 80dB Gain
DL : 60dB to 90dB Gain
0dB to 30dB Attenuation.
Used to set the UL/DL system gain.
System Display
Manufacturer, Repeater Type, Repeater S/N, S/W
Version, Temperature
Displays the repeater name and
information.
Location Display
Company, Address, City, State,
Contact
Displays the repeater location information.
Control Send
All Control Page Settings
Used to save settings in the Control page.
Isolation
Isolation Value, Isolation Max Gain Display
Refer to
Section 6 System Operation
for more information about the GUI.