background image

Section BXM‐161‐7HE‐20A

030‐101765 Rev. B

R

17

1311IARB

Figure 23.     Replacing the Heat Exchanger

To remove the heat
exchanger, loosen
the Allen screws
on the inside wall
of the cabinet door.

the FAN A Euro connecor

in the controller card

(2 wires for each fan,

join same-colored wires together

from each fan prior to insertion

into connector in controller card)

Upper Fan

Lower Fan

Both fans are wired to

Cover removed in

visual clarity of fan

DO NOT REMOVE

THE COVER !!

locations only

this figure for

5.3

Replacing the Door Sensor Switch

The door alarm sensor switch cannot be field repaired. Should
a problem be suspected with the door switch, remove the switch
and return it to Westell for service, then replace it. To remove
and replace the door alarm switch, proceed with the following
instructions.

‐ WIRE AND BLOCK DISCONNECTION NOTE ‐

The Euro‐connector blocks used for making DC distribution and
alarm wire connections facilitate a simple group disconnection of
all alarm and dc distribution wire connections; there's no need to
unscrew each wire. Simply remove the entire block by pulling the
blocks away from the panel.

‐ CAUTION ‐

To avoid electrical shock, turn off any DC or AC power feeds
to the controller before beginning this procedure.

1.

Open the cabinet. 

Open the cabinet door if accessing the

door switch from the front; if accessing the switch from the
rear, remove the rear access panel.

2.

Disconnect switch power. 

Disconnect the door alarm

switch power by removing the door alarm Euro connector
at the bottom of the controller card.

3.

Remove door switch. 

Remove the door alarm switch with

a flat screwdriver by snapping/prying it out of the bracket
which houses it.

4.

Disconnect wires at door switch.

 Carefully disconnect

each wire from the switch, noting which terminal was used
and labelling the color or polarity of each connector, for
easy re‐connection to the new door switch.

5.

Wire then install the new switch into the mounting bracket.

Connect the wires into their proper positions in the new
switch. 

 

Insert the new door sensor switch into its mount­

ing bracket from the rear side so the door sensor button
protrudes through the hole for it at the front of the mount­
ing bracket; press or snap it into place.

6.

Test. 

Verify that the door alarm is not present when instal­

lation is complete and power is re‐applied.

6.

CUSTOMER & TECHNICAL SERVICES

6.1

Customer Service & Technical Assistance

If technical or customer assistance is required, contact Westell
by calling or using one of the following options:

Voice: (800) 377‐8766
email:

[email protected]

For additional information about Westell, visit the Westell
World Wide Web site at http://

www.Westell.com.

6.2

Part Numbers

This equipment is identified by a product number
(A90‐BXM1619‐7HE), which consists of three parts: the issue
letter of the equipment (A), the assembly type (90), and the spe­
cific model number (BXM1619‐7HE). Each time a change is
made to the product which changes the form, fit, or function of
the product, the issue letter is incremented or advanced by one.
Be sure to indicate the issue level as well as the model number
when making inquiries about the equipment.

7.

WARRANTY & RETURNS

7.1

Warranty

Westell warrants this product to be free of defects at the time of
shipment. Westell also warrants this product to be fully function­
al for the time period specified by the terms and conditions
governing the sale of the product. Any attempt to repair or
modify the equipment by anyone other than an authorized West­
ell representative will void the warranty.

7.2

Return and Replacement Policy

Westell will repair or replace any defective Westell equipment
without cost during the warranty period if the unit is defective
for any reason other than abuse, improper use, or improper
installation. Before returning the defective equipment, first re­
quest a Return Material Authorization (RMA) number from
Westell. Once an RMA number is obtained, return the defective
unit, freight prepaid, and a brief problem description to:

Voice: (630) 375‐4457
email: [email protected]

Replacements will be shipped in the fastest manner consistent
with the urgency of the situation. Westell will continue to repair
or replace faulty equipment beyond the warranty period for a
nominal charge. Contact Westell for details.

Содержание Boxer BXM1619-7HE

Страница 1: ...ocu ment adds several G models to Table 4 adds the NESC OSHA note above adds the GR 487 Issue 4 compliant bullet list feature in Paragraph 1 5 for the 7HEG model and updates Figure 4 and Figure 6 to s...

Страница 2: ...Exchanger removable and replaceable 1 5 Product Features Each Boxer 16 cabinet comes fully assembled pre wired tested and ready for field provided customer equipment installation and includes the foll...

Страница 3: ...ns and vents Security is provided via a 2 point latch a tamper proof screw lock and a padlock hasp Side wall lift ears Paragraph 2 1 2 5 are provided for temporary installation lift assistance The bot...

Страница 4: ...ed for conve nient access to the rear of equipment mounted inside Boxer 16 The purpose of the access panel is to facilitate equipment ac cess cabling and servicing The panel is secured with six tamper...

Страница 5: ...ameter knock outs in the floor of the Boxer 16 cabinet where an option al battery box attaches to the cabinet hole patterns of both units match KNOCK OUT REMOVAL NOTE Always remove knock outs where ho...

Страница 6: ...nterior of the cabinet reaches 35 C 95 F and turn off when the internal cabinet temperature cools to 25 C 77 F At the core of the heat ex change system are numerous aluminum fins visible through the c...

Страница 7: ...card Two fans are wired to each set of terminals Shaded rows indicate installer connections TEMP ALARM DOOR ALARM and Power Table 2 Controller Card Connectors 2 2 6 AC Duplex GFI Outlets for Installe...

Страница 8: ...ectrostatic discharge procedures must be followed to maintain personal and equipment safety Do not store units near magnetic electromagnetic or electrostatic fields Always store or ship units in the o...

Страница 9: ...out from either direction per hole size WEIGHT NOTE The Boxer 16 cabinet weighs 80 pounds The weight of the inter nal equipment installed in the Boxer 16 should not exceed 90 pounds The mounting surf...

Страница 10: ...mbined weight of the cabinet and the equipment mounted inside the cabinet Westell recommends a minimum cabinet installation height of 30 from the ground 1 Find best wall position Locate the best mount...

Страница 11: ...ug 11 Determine next step or close up cabinet and clean the site Repeat Steps 6 8 of Paragraph 3 6 1 to determine the next step or finish the physical cabinet installation 3 6 3 Mounting on a Pole or...

Страница 12: ...it BXA PM02 Contents Threaded rod Bracket Washers and Nuts BXA PM03 kit also includes a shelf Figure 18 Boxer Mounted on Pole with Pole Mount Kit Pole Also see the instructions in the optional BXA PM0...

Страница 13: ...and gap less suppressors The pedestal shall be capable of accepting 120 240 volts single phase and provide hardware for mounting a power meter However Boxer 16 must only be supplied with 120 volts Fo...

Страница 14: ...hole pattern accommodates a wide variety of equipment and mounting bracket hole patterns Always follow company practices and the guidelines below when mounting equipment inside the cabinet 1 Verify th...

Страница 15: ...te and verify no equipment tie downs cables or wires will interfere with the closing of the door Clean up the installation site per company practice 3 18 Closing and Locking the Cabinet Upon completio...

Страница 16: ...mpartment from the door Make a written note of the length of the old power cord RETURN UNIT NOTE Return the old defective unit to Westell and receive a replace ment new unit see Paragraph 7 2 for deta...

Страница 17: ...ensor switch into its mount ing bracket from the rear side so the door sensor button protrudes through the hole for it at the front of the mount ing bracket press or snap it into place 6 Test Verify t...

Страница 18: ...optional battery box and pole mounted with the pole mount kit see Table 4 Table 3 Boxer 16 Cabinet Physical Specifications 8 SPECIFICATIONS 8 1 Electrical and Physical Specifications The Westellr Boxe...

Страница 19: ...on 48VDC A90 BXSC1619 4H Boxer 20 20 RU 19 wide rack Main Cabinet 400W heat exchanger always on 48VDC A90 BXM2019 4HE 400W heat exchanger temp controlled 24 or 48VDC A90 BXM2019 4HE3 Same as the 4HE...

Страница 20: ...0 101765 Rev B R 20 1311IARB Appendix A Product Views Figure 24 Bottom View of Boxer 16 Cabinet Showing Dimensions and Knock outs Mounting lift brackets door and heat exchanger not shown For mounting...

Страница 21: ...Section BXM 161 7HE 20A 030 101765 Rev B R 21 1311IARB Figure 25 Front Exterior View of Boxer 16 Cabinet 24 0 33 0 24 5 41 0 39 0 Rear View Panel On...

Страница 22: ...Section BXM 161 7HE 20A 030 101765 Rev B R 22 1311IARB Figure 26 Right Side Exterior View of Boxer 16 Cabinet 33 0 18 05 20 60 28 10 41 0...

Отзывы: