Pro-EC44 2-Loop Graphical Profile Controller & Recorder
Pro-EC44 Product Manual - 59540-2 September 2014
Page 63
Recorder Status
Information
Current information about the data recorder feature, including if a recording
is in progress (Recording or Stopped); the recording mode (FIFO or Record
Until Memory Is Used); a % memory use bar-graph and the estimated
available time remaining based on the data selected and memory left.
If the alarm status is recorded and is likely to change often, take this into
account when determining if there is sufficient memory available.
Icons are displayed for active recording triggers. If any are active, the
selected data will be recorded.
Manual Record
Digital Input
Profile Record
Alarm Record
-
see the Data Recorder in section on page 97
Clear Recordings
Clears the recorder memory. Download any recorded data before use.
Caution:
This permanently deletes All recorded data.
Profiler Setup Menu
Screens marked
will not time-out automatically. They must be completed for a valid profile
to be created.
Refer to the Profiler section on page 87 for more details about the profiler.
Entry into the Profiler Setup Menu
The Profiler Setup Menu is entered from the Main Menu
Hold down
R
and press
U
to enter the Main Menu.
Press
D
or
U
to select the Profiler Setup Menu
Press
R
to enter the Profiler Setup Menu.
Navigating the Profiler Setup Menu
Press
R
to move forward, or
L
to move backwards through the screens.
Press
D
or
U
to select or change the value as required.
Holding down
R
or
L
for more than 1 second skips immediately to the next/previous
screen accepting
ALL
values as shown.
Hold down
R
and press
U
to return to the Main Menu
Scrolling “Help Text” is shown at the bottom of the screens to aid navigation.
PROFILER SETUP MENU SCREENS
Profiler Setup Menu
Unlocking
Enter correct code number to access Profiler Setup Menu.
Factory Default value is 10.
Profile Setup
Options
Select the required profile setup sub-menu option from: General
Configuration; Create a Profile; Edit a Profile Header; Edit a Profile
Segment; Insert a Segment; Delete a Segment; Delete a Profile or Delete
ALL Profiles.
Note:
Entry into this mode is security-protected by the profiler setup menu lock
code. Refer to the Lock Code Configuration sub-menu.
Содержание Pro-EC44
Страница 1: ...Pro EC44 2 Loop Graphical Profile Controller Recorder Pro EC44 User Guide 59540 2 ...
Страница 2: ......
Страница 6: ......