RD232-H Instruction Manual P.15 

21 

011 

24 

100 

25 

101 

26 

110 

27 

111 

 

Bit3

Bit5: Wrong parameter

fixed as 000 

Bit6

Bit7: Instrument working mode

there are four mode: 

 

 

Mode 1 (Long Data Mode: Set-up as 00)

 

GID of every instrument can receive info at this mode, and it can specifically 

use on data info that is larger than 127 Bytes. 

 

 

Mode 2 (ID Data Mode 1: Set-up as 01)

 

Once GID can transmit to particular SID instrument under this mode, it is 

one to many; the single info must 

127 Bytes. 

Transmission: The 1

st

 Byte is the SID of the receiver, and from the 2

nd

 Byte, 

it becomes data. 

Example: The SID of device A is 55, the SID of device B is 88, and they have 

the same GID. Under mode 2, device A is going to transmit data 

0x1234567890, 5 Bytes in total, to B device, A then sends data 

0x881234567890, 6 Bytes in total to B, B will receive 0x551234567890, 6 

Bytes in total. The 1

st

 Byte is the SID of the transmitter.

 

 

 

Mode 3 (ID Data Mode 2: Set-up as 10)

 

Once GID can transmit to particular SID instrument under this mode, it is 

one to many; the single info must 

127 Bytes. 

Transmission: Data shall be transmitted under the same rule of the 13

th

 to 

32

nd

 Byte. 

Example: The GID of device A = AAAA, SID = 55; the GID of device B = 

BBBB, SID = 88; the GID of device C = CCCC, SID = 99. 

A is going to transmit 0x1234567890 to B, 5 Bytes in total. A then sends 

0x04FFBBBB881234567890, 10Bytes in total, to B, B will receive 

0x1234567890, 5 Bytes in total. 

A is going to transmit 0x1234567890, 5 Bytes in total, to B via C. A then 

sends 0x08FFBBBB88FFCCCC991234567890, 14 Bytes in total, C will 

receive 0x1234567890, 5 Bytes in total, but B will not receive any data. 

 

Содержание RD232-H-RS485-434M

Страница 1: ...nstruction Manual P 1 WENSHING Wireless Data Radio Modem RS485 TTL 432 436MHz 500mW Multi point Transceiver Version History Version Date Changes V1 01 Sep 21 2018 1st Edition Model RD232 H RS485 434M...

Страница 2: ...cope Description 3 Contact Us 3 Key Feature 4 Application 4 Electrical Characteristic 4 Block Diagram 5 Dimension 6 Pin Assignment 7 Installation Instructions 8 Instruction Mode 13 Into Set Up Mode 13...

Страница 3: ...ate particular attention to the matter reminded to use Please respect this statement recorded by the note When consumers in contravention of this statement recorded note of the operation I am afraid o...

Страница 4: ...reless RS232 Active RFID Base Station Transceiver Electrical Characteristic 7 24V Power Supply Parameter Min Typ Max Unit Condition Operating Condition Operating Temperature Range 10 70 Operating Supp...

Страница 5: ...http www wenshing com tw http www rf net tw RD232 H Instruction Manual P 5 Block Diagram...

Страница 6: ...http www wenshing com tw http www rf net tw RD232 H Instruction Manual P 6 Dimension Unit mm...

Страница 7: ...http www wenshing com tw http www rf net tw RD232 H Instruction Manual P 7 Pin Assignment...

Страница 8: ...s Click on the Software Application software button on the product information page to begin downloading product drivers Decompress the Product driver archive After decompression find the Windows XP_S...

Страница 9: ...ttp www wenshing com tw http www rf net tw RD232 H Instruction Manual P 9 Left click on Next Check on I agree this contract and left click on Next to continue Right click on Finish to complete and qui...

Страница 10: ...into the USB hub then open the software s archive find and double click on the Test file then find and click on the sscom32 exe file A PC RD232 H USB Open the software choose your ComNum serial number...

Страница 11: ...omputer B s USB hub Open the software s file and find the Test file In the Test file find and double click on sscom32 exe B PC RD232 H USB Open the software choose your ComNum serial number COM3 for e...

Страница 12: ...uter A s screen type ABCDEF under the data input column If pairing successful you can find the same text on Computer B s screen A PC B PC On Computer B s screen type HIJKLMN under the data input colum...

Страница 13: ...ete the original parameter and recover back to the new set code that is written in when it is out from factory Read in Inside Parameter Transmit value 0xFF FF FF 55 AA BB FE Receive value 0xFE03 00 00...

Страница 14: ...RF transmit rate must greater than interface speed rate when setting up it prevents having the wrong information 8th to 10th Byte Working frequency calculation MHz 1000 KHz and transfer to 16 Bytes Fo...

Страница 15: ...ce A is going to transmit data 0x1234567890 5 Bytes in total to B device A then sends data 0x881234567890 6 Bytes in total to B B will receive 0x551234567890 6 Bytes in total The 1st Byte is the SID o...

Страница 16: ...2 05 FF 12 34 55 11 22 33 44 00 From 13th Byte it can be seen that the effective 5 Bytes data are FF 12 34 55 11 FF 12 34 55 11 represents GID 1234 SID 55 and 11 When this equipment receives data via...

Отзывы: