![Wenglor SEFB Series Скачать руководство пользователя страница 94](http://html1.mh-extra.com/html/wenglor/sefb-series/sefb-series_operating-instructions-manual_956883094.webp)
Parameters Configuration
94
9.3.3 Menu Structure
The menu is laid out as follows:
Range
HI RANGE
CODE
Encoding
9.3.4 Parametrization of the Range and Coding
• The “Menu down” key (
) can be used to switch between the two settings (range/coding).
• The “Apply” key (
) changes the setting within the menu item:
– Range: Switch between low range and high range
– Coding: Switch between coding ON and coding OFF
• The current set parameter configuration is indicated by different flashing frequencies:
Display during
parameter configuration
Meaning
Display during
operation
HI RANGE
Flashing, duty cycle 15 %
LED on
LED off
Low Range
HI RAN
Flashing, duty cycle 85 %
LED on
LED off
High Range
HI RAN
CODE
Flashing, duty cycle 15 %
LED on
LED off
Coding OFF
CODE
Flashing, duty cycle 85 %
LED on
LED off
Coding ON
CODE
• To apply the settings, both keys ([menu down
] and [apply
]) must be pressed at the same time until
the red “ERROR” LED goes out (approx. 2 s).
• By way of acknowledgment, all LEDs light up at the same time before the final setting is shown according
).
• If no acknowledgment takes place, the settings are dismissed and the most recent saved setting is applied
again.