15
6.1. Default Settings
PNBCxxx
IP address
192.168.0.225
Subnet mask
255.255.0.0
Evaluation method
COG
Average filter
0 (corresponds to the off state)
Sampling rate
Auto
Output rate
10 kHz
Laser
Auto
Offset
0.0 mm
Analog mode
4 to 20 mA
E1
Ext. teach-in: O3
E2
Ext. teach-in: O4
A3
Switching output: PNP / NO
A4
Switching output: PNP / NO
Input load: 2 mA
On
Input
Operating voltage active
Teach-in mode
Foreground teach-in
7. Initial Start-Up
Two connector plugs are integrated in to the sensor’s housing. The 8-pin plug supplies the sensor with +24 V
operating voltage, whereas communication for parameters configuring and process data is conducted via the
4-pin socket. We recommend the exclusive use of Ethernet switches in order to optimize data communication.
Please note:
If Gigabit Ethernet cards are used, the polarity of the Tx and Rx conductors might not be correctly
detected. Connecting sensors directly may result in complications. With an Ethernet crossover cable (cross-
link), the sensor functions flawlessly via a PC network card. As an alternative, a commercially available 100 Mbit
Ethernet switch can also be used.