background image

11

Retro-Reflex Sensors for Clear Glass Recognition

5.  Installation and Electrical Connection

5.1 Installation

• Protect the product from contamination during installation.
• Observe all applicable electrical and mechanical regulations, standards, and safety rules.
• Protect the product against mechanical influences.
• Make sure that the sensor is mounted in a mechanically secure fashion.
• Specified torque values must be complied with

 (see section “3.2 Layout”, page 9)

.

ATTENTION!
Risk of property damage in case of improper installation!

The product may be damaged.
• Installation instructions must be complied with.

CAUTION!
Risk of personal injury or property damage during installation!

Personal injury and damage to the product may occur.
• A safe installation environment must be assured.

5.2 Electrical Connection

213

 

215

Legend

Wire Colors according to IEC 60757

Platinum measuring resistor
not connected
Test Input
Test Input inverted
Trigger Input
Ground for the Trigger Input
Analog Output
Ground for the Analog Output
Block Discharge
Valve Output
Valve Control
Valve Control Output 0 V
Synchronization
Ground for the Synchronization
Receiver-Line
Emitter-Line
Grounding
Switching Distance Reduction
Ethernet Receive Path
Ethernet Send Path
Interfaces-Bus A(+)/B(–)
Emitted Light disengageable
Magnet activation
Input confirmation
Contactor Monitoring 

Black
Brown
Red
Orange
Yellow
Green
Blue
Violet
Grey
White
Pink
Green/Yellow 

Supply V
Supply Voltage 0 V
Supply Voltage (AC Voltage)
Switching Output     

(NO)

Switching Output    

(NC)

Contamination/Error Output   (NO)
Contamination/Error Output   (NC)
Input (analog or digital)
Teach Input
Time Delay (activation)
Shielding
Interface Receive Path
Interface Send Path
Ready
Ground
Clock
Output/Input programmable

Power over Ethernet
Safety Input
Safety Output

Signal Output
Ethernet Gigabit bidirect. data line (A-D)  
Encoder 0-pulse 0-0 (TTL)

Encoder A/A (TTL)
Encoder B/B (TTL)
Encoder A
Encoder B
Digital output MIN
Digital output MAX
Digital output OK
Synchronization In
Synchronization OUT
Brightness output
Maintenance
reserved

PT

PT

Содержание P1NK Series

Страница 1: ...EN Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Version 1 0 0 Status 25 07 2018 www wenglor com P1NKxxx Retro Reflex Sensors for Cl...

Страница 2: ...class 6 3 Technical Data 7 3 1 Technical Data 7 3 1 1 Spot diameter 8 3 1 2 Smallest detectable part 8 3 1 3 Switching distance 8 3 2 Complementary Products 9 3 3 Layout 9 3 4 Control Panel 10 3 5 Sc...

Страница 3: ...zed by means of symbols and attention getting words Safe use of the product is only possible if these safety precautions and warnings are adhered to The safety precautions and warnings are laid out in...

Страница 4: ...pproved replacement parts Unapproved modification of products These operating instructions do not include any guarantees from wenglor with regard to the described procedures or specific product charac...

Страница 5: ...ct can be used in the following industry sectors Special machinery manufacturing Heavy machinery manufacturing Logistics Automotive industry Food industry Packaging industry Pharmaceuticals industry P...

Страница 6: ...uct is modified Personal injury and damage to equipment may occur Non observance may result in loss of the CE marking and the guarantee may be rendered null and void Modification of the product is imp...

Страница 7: ...ption operating voltage 24 V 20 mA Switching frequency 2000 Hz Switching frequency speed mode 3500 Hz Response time 0 25 ms Response time speed mode 0 14 ms Temperature drift 5 Temperature range 40 60...

Страница 8: ...nge Reflector Range RQ100BA 0 2 60 m RR21_M 0 0 65 m RE18040BA 0 1 50 m ZRME01B01 0 0 25 m RQ84BA 0 1 80 m ZRME03B01 0 1 10 m RR84BA 0 2 20 m ZRAE02B01 0 0 90 m RE9538BA 0 0 85 m ZRMR02K01 0 0 30 m RE...

Страница 9: ...an provide you with suitable connection technology for your product Suitable mounting technology no 350 Suitable connection technology no 2 S02 IO Link master wTeach2 software DNNF005 3 3 Layout 1 Opt...

Страница 10: ...case of damage con ditionally accept the package and notify the manufacturer of the damage Then return the device making reference to damage in transit 4 2 Storage The following points must be taken i...

Страница 11: ...Input Ground for the Trigger Input Analog Output Ground for the Analog Output Block Discharge Valve Output Valve Control Output Valve Control Output 0 V Synchronization Ground for the Synchronization...

Страница 12: ...arning blinking LED Display LED Diagnosis Cause Elimination Continuous blinking at approx 2 5 Hz Contamination Carefully clean the optic cover with a cloth Aged emitter diode Replace the sensor Unreli...

Страница 13: ...or Reflector Sensor Reflector Object Sensor Reflector Object Object Sensor Reflector Sensor Reflector Object Sensor Reflector Object Required action in case of fault NOTE Shut down the machine Analyze...

Страница 14: ...settings are possible via the IO Link interface The IODD can be found at www wenglor com in the product s download area 8 Maintenance Instructions NOTE This wenglor sensor is maintenance free Cleaning...

Страница 15: ...tage IODD IO Device Description MTTFd Mean Time to Dangerous Failure 10 2 Change Index Operating Instructions Version Date Description Change 1 0 0 25 07 18 Initial version of the operating instructio...

Отзывы: